KITOZER Remote Power Panel (RPP) Solution for Computer Rooms

1. System Introduction

1.1 Definition and Core Value of Remote Power Panel

Remote Power Panel (RPP) is the core equipment of the terminal power distribution system in data center computer rooms. It is installed at the front or end of each cabinet row, responsible for isolating, distributing, controlling and monitoring electric power output from UPS, so as to provide safe and reliable power supply for IT cabinets in rows.

Adopting modular intelligent design, KITOZER RPP integrates functions including precision power distribution, real-time monitoring, fault early warning and energy efficiency management. It serves as a key infrastructure for modern data centers to realize refined power management and high-availability power supply.

1.2 System Positioning and Functions

In the power distribution architecture of data centers, KITOZER RPP acts as the “last mile”, connecting UPS output and IT loads. Its main functions are as follows:

  • Power Distribution: Distribute power from upstream UPS to PDU of each IT cabinet as required.
  • Safety Protection: Provide multi-level protection against overload, short circuit, electric leakage, overvoltage and undervoltage.
  • Real-time Monitoring: Precisely measure electrical parameters such as voltage, current, power, electric energy and harmonic.
  • Fault Early Warning: Adopt audible & visual alarm and remote notification to quickly locate faults and reduce Mean Time To Repair (MTTR).
  • Energy Efficiency Management: Collect energy consumption data to support PUE optimization and facilitate the construction of green data centers.
  • Flexible Expansion: Support hot-swap and modular design to meet the dynamic capacity expansion demands of high-density IT loads.

1.3 Design Standards & Specifications

KITOZER RPP strictly complies with the following domestic and international standards:

  • GB 50174-2017 Code for Design of Data Centers
  • TIA-942 Telecommunications Infrastructure Standard for Data Centers
  • IEC 60439-1 Low-voltage switchgear and controlgear assemblies – Part 1: General rules
  • GB 7251.1 Low-voltage switchgear and controlgear assemblies – Part 1: General rules
  • YD/T 1821 Environmental Requirements for Telecommunication Central Office
data center display cabinet solution (2)

2. System Composition

KITOZER RPP features a modular design. Its core components and functions are listed below:

Module CategoryCore ComponentsFunction Description
Cabinet Structure19-inch standard cabinet, aluminum-zinc coated steel plate, epoxy powder coatingIP40 protection grade, corrosion resistance, anti-electromagnetic interference and high load-bearing capacity
Input UnitMain circuit breaker (ACB/MCCB), isolation transformer, surge protectorReceive power from UPS; provide short-circuit protection, electrical isolation and surge protection
Output UnitBranch circuit breaker (MCB/MCCB), terminal blocks/socketsDistribute power to IT cabinets with independent protection for each circuit; support hot swap
Monitoring SystemIntelligent monitoring module, HMI touch screen, sensorsCollect electrical parameters in real time; support local display, remote transmission and fault alarm
Communication ModuleRS485, TCP/IP, SNMP interfaceCompatible with Modbus, BMS and DCIM systems to realize remote management
Auxiliary UnitCooling fan, indicator light, temperature & humidity sensorHeat dissipation, status indication and ambient monitoring
AccessoriesCopper busbar, cables, insulation parts, identification systemEnsure reliable electrical connection and operational safety

3. System Classification

3.1 Classification by Power Supply Type

TypeApplication ScenariosCore Features
AC Remote Power Panel (AC-RPP)Traditional data centers, enterprise computer roomsInput: AC 380V/220V; support three-phase/single-phase output, compatible with standard power supply for IT equipment
DC Remote Power Panel (DC-RPP)Telecommunication computer rooms, HVDC power supply systemsInput: DC 48V/240V/336V; higher efficiency, ideal for communication equipment and high-density servers
AC/DC Hybrid Remote Power PanelEnvironments with mixed IT loadsProvide both AC and DC output to meet power demands of different devices

3.2 Classification by Functional Grade

GradeFunctional FeaturesApplication Scenarios
Basic RPPBasic power distribution and protection functionsSmall computer rooms, edge computing nodes and budget-limited projects
Intelligent RPPIntegrated monitoring and remote management functionsMedium-sized data centers and enterprise-level computer rooms requiring remote operation & maintenance
Precision RPPHigh-precision measurement (Class 0.2), harmonic analysis and fault locationLarge-scale data centers, core computer rooms of finance and telecom industries with high availability requirements
Modular RPPHot-swappable modules and rapid capacity expansionCloud data centers and hyper-converged architectures with dynamically changing loads

3.3 Classification by Installation Method

  • Floor-standing RPP: Independent floor installation, rated current 630A-1250A with large capacity, suitable for large-scale data centers.
  • Rack-mounted RPP: Installed on 19-inch standard rack (3U-12U), space-saving, applicable to small & medium-sized computer rooms and edge data centers.
  • Embedded RPP: Embedded at the end of cabinet rows with integrated design, aesthetic and space-efficient.
data center display cabinet solution (3)

4. KITOZER System Configuration List

4.1 Configuration List of Basic RPP

No.Component NameModelSpecificationsQuantityBrand
1CabinetKITOZER-RPP-800800mm×600mm×2000mm, IP40, aluminum-zinc coated steel1 SetKITOZER
2Main Input SwitchKITOZER-MCCB-400400A/3P, breaking capacity: 50kA1 Pc.KITOZER
3Branch Output SwitchKITOZER-MCB-3232A/1P, breaking capacity: 10kA24 Pcs.KITOZER
4Surge Protection ModuleKITOZER-SPD-4040kA, 3-phase + N, Type 21 SetKITOZER
5Copper Busbar SystemKITOZER-BUS-40040×5mm pure copper busbar with insulation treatment1 SetKITOZER
6Indication UnitKITOZER-IND-01Power indicator light, fault indicator light1 SetKITOZER
7Terminal BlockKITOZER-TER-6363A, flame-retardant and insulated24 SetsKITOZER

4.2 Configuration List of Intelligent RPP (Additional to Basic Model)

No.Component NameModelSpecificationsQuantityBrand
8Intelligent Monitoring ModuleKITOZER-IM-02Class 0.5 accuracy; measure voltage, current, power and electric energy1 Pc.KITOZER
9HMI Touch ScreenKITOZER-HMI-77-inch color touch screen for local data display1 Pc.KITOZER
10Communication ModuleKITOZER-COM-03RS485 + TCP/IP, support Modbus-RTU/TCP1 Pc.KITOZER
11Sensor KitKITOZER-SEN-01Class 0.2 current transformer, voltage sensor1 SetKITOZER
12Alarm UnitKITOZER-ALM-02Audible & visual alarm, support remote notification1 Pc.KITOZER

4.3 Configuration List of Precision RPP (Additional to Intelligent Model)

No.Component NameModelSpecificationsQuantityBrand
13Precision Monitoring ModuleKITOZER-PM-01Class 0.2 accuracy, THD harmonic analysis and waveform recording1 Pc.KITOZER
14Fault Location ModuleKITOZER-FL-01Accurate branch fault identification, positioning time < 1s1 Pc.KITOZER
15Temperature & Humidity Monitoring ModuleKITOZER-ENV-01Accuracy: ±0.5℃, ±3%RH1 Pc.KITOZER
16Insulation Monitoring DeviceKITOZER-IMD-01Monitor grounding insulation resistance to prevent electric leakage1 Pc.KITOZER
17Network Security ModuleKITOZER-SEC-01Support HTTPS and data encryption to defend against network attacks1 Pc.KITOZER

5. System Schematic Diagram

5.1 Schematic Diagram of AC Intelligent RPP

UPS Output → Main Input Switch (ACB/MCCB) → Surge Protection Module → Isolation Transformer (Optional) → Copper Busbar System

→ Branch Switch (MCB/MCCB) × N → Terminal Block → IT Cabinet PDU

Intelligent Monitoring Module ← Voltage/Current Sensors ← Each Branch Circuit

HMI Touch Screen ↔ Communication Module (RS485/TCP/IP) ↔ DCIM/BMS System

Audible & Visual Alarm Unit ← Fault Detection Module

5.2 Schematic Diagram of Dual Power Redundant RPP

UPS A Output → Input Switch A → ATS Automatic Transfer Switch → Surge Protection Module → Copper Busbar System

UPS B Output → Input Switch B → ATS Automatic Transfer Switch → Surge Protection Module → Copper Busbar System

Copper Busbar System → Branch Switch × N → IT Cabinet PDU

Intelligent Monitoring Module → Remote Management System

5.3 Schematic Diagram of DC RPP

HVDC Power Supply → Input Fuse/Circuit Breaker → Surge Protection Module → DC Busbar

→ Branch Circuit Breaker × N → Terminal Block → Communication Equipment / DC Server

DC Monitoring Module ← Shunt/Hall Effect Sensor ← Each Branch Circuit

HMI Touch Screen ↔ Communication Module ↔ Power Management System

data center display cabinet solution (4)

6. Product Technical Parameters

6.1 General Technical Parameters

ParameterTechnical IndexRemarks
Rated VoltageAC 380V/220V (3-phase 4-wire) / DC 48V/240V/336VCompliant with power supply standards for IT equipment
Rated Frequency50Hz/60HzCompatible with different power grid standards
Input Current Range63A ~ 1250ASelectable by model
Branch Current Range16A ~ 63AMax. 63A load per circuit
Number of Branches12 ~ 126 circuitsCustomized according to cabinet size and configuration
Measurement AccuracyVoltage/Current: Class 0.2; Power/Electric Energy: Class 0.5Standard for precision RPP
Protection GradeIP40Prevent dust and water droplets ingress
Dielectric Strength2500V/min, no breakdown or flashoverComply with IEC 60439
Breaking Capacity50kA/1sEnsure safe cut-off under short circuit fault
Cabinet Dimension600×600×2000mm ~ 800×1000×2200mmFloor-standing / Rack-mounted optional
Operating Temperature0℃ ~ 40℃Adapt to computer room environment
Relative Humidity10% ~ 90% (non-condensing)Avoid condensation affecting insulation performance
Altitude≤2000mDerating required for higher altitude

6.2 Technical Parameters of Intelligent Monitoring System

ParameterTechnical IndexFunction Description
Monitored ItemsVoltage, Current, Power, Electric Energy, Power Factor, THD, Temperature & HumidityFull-range electrical parameter monitoring
Communication InterfaceRS485 (Modbus-RTU), RJ45 (TCP/IP), SNMPIntegrate with mainstream management systems
Data Refresh Rate1 time/secondReal-time load status feedback
Alarm ModeAudible & visual alarm, remote notification (Email/SMS), dry contact outputMulti-level fault early warning
Historical Data Storage≥ 1 yearSupport energy consumption analysis and trend prediction
Display7-inch color touch screenLocal data visualization and easy operation
Communication Baud Rate9600 ~ 115200bpsAdapt to diverse communication requirements
Supported ProtocolsModbus-RTU/TCP, SNMPv1/v2c/v3, BACnetCompatible with mainstream DCIM and BMS systems

6.3 Modular Technical Parameters

ParameterTechnical IndexAdvantage Description
Module TypePower distribution module, monitoring module, communication moduleIndependent functions, configurable on demand
Hot-swap FunctionSupport live plug & playOn-site maintenance without interrupting other loads
Module Replacement Time≤ 5 minutesRapid recovery and shorter MTTR
Expansion CapacitySupport online addition of branch modulesAdapt to dynamically changing loads
Module CompatibilityUniversal interchange for full series modulesReduce spare parts inventory cost
data center display cabinet solution (5)

7. Application Scope

7.1 Industry Application Scenarios

IndustryTypical ApplicationRecommended Product Type
Internet Data CenterCloud computing platform, large-scale data centerModular precision RPP for high density and rapid expansion
Finance IndustryBank core system, securities trading platformDual power redundant intelligent RPP for 99.999% high availability
Telecommunications OperatorTelecommunication computer room, 5G core networkDC RPP adapted for communication equipment
Government & Public InstitutionE-government, data sharing platformIntelligent RPP for remote O&M and energy management
EnterpriseERP system, private cloud, database serverPrecision RPP to ensure business continuity
Edge ComputingEdge data center, IoT gatewayRack-mounted RPP for space-saving and easy deployment
Medical IndustryMedical imaging system, electronic medical record systemDual power RPP complying with medical power supply safety standards

7.2 Adaptation for Different Computer Room Types

Computer Room TypeFeaturesRecommended Solution
New Large-scale Data CenterHigh density and high availability requirementsModular precision RPP + DCIM integrated system
Computer Room RenovationUpgrade existing infrastructureIntelligent RPP compatible with legacy power distribution systems
Edge Computing NodeMiniaturization and distributed deploymentBasic rack-mounted RPP for rapid deployment
Container Data CenterLimited space and mobility requirementsCustom compact RPP for container environment
Green Data CenterPUE optimization and energy efficiency managementPrecision RPP providing data support for PUE analysis

8. Product Advantages

8.1 Technical Advantages

  1. Modular design with hot-swap function; module replacement within 5 minutes to reduce outage risks and adapt to dynamic loads.
  2. Class 0.2 high-precision monitoring module to capture electrical parameters accurately and support energy efficiency optimization.
  3. Multi-level safety protection including overload, short circuit, electric leakage, overvoltage, undervoltage and surge protection to secure IT equipment.
  4. Intelligent fast fault location reduces MTTR by over 70% and improves O&M efficiency.
  5. Compatible with mainstream protocols such as Modbus, SNMP and BACnet for seamless integration with DCIM systems.
  6. Redundant design for key components; MTBF ≥ 100,000 hours for high reliability.

8.2 Performance Advantages

  1. Optimized air duct design for efficient heat dissipation; temperature difference inside cabinet ≤ 3℃, extending service life of electronic components by 30%.
  2. Low harmonic distortion (THD < 3%) to minimize interference to UPS and IT devices.
  3. Wide input voltage range (±15% fluctuation tolerance) for unstable power grid environments.
  4. Fault response time < 100ms to cut off faulty circuits promptly.
  5. High power density; max. 126 output circuits per cabinet to meet high-density IT load demands.

8.3 O&M Advantages

  1. Multiple remote management methods including Web, APP and SNMP to reduce on-site work.
  2. Intuitive 7-inch color touch screen for easy local operation and parameter viewing.
  3. Auto-generated reports on energy consumption, alarms and events for data analysis.
  4. Predictive maintenance based on historical data and trend analysis to warn potential faults in advance.
  5. Excellent scalability with modular architecture to support online expansion, protect investment and lower Total Cost of Ownership (TCO).
data center display cabinet solution (7)

9. Bid Specification Parameters

9.1 Core Bid Parameters

ParameterBid RequirementsReference Standard
BrandOriginal KITOZER product; manufacturer authorization certificate requiredGuarantee product quality and after-sales service
Modular DesignSupport hot-swap; module replacement within 5 minutes without power cutIEC 61935
Measurement AccuracyVoltage/Current ≥ Class 0.2; Power/Electric Energy ≥ Class 0.5GB/T 17215
Breaking CapacityMain switch ≥ 50kA; Branch switch ≥ 10kAIEC 60947
Protection Grade≥ IP40; third-party test report requiredIEC 60529
Communication ProtocolSupport Modbus-RTU/TCP and SNMPv3; protocol certification requiredEnsure system compatibility
Redundancy DesignDual power input + ATS automatic transfer; no single point of failureGB 50174-2017
MTBFMean Time Between Failures ≥ 100,000 hours; manufacturer test report requiredEquipment reliability specification
CertificationCE, UL and CQC certifications; copy of certificates requiredInternational and domestic safety standards

9.2 Technical Response Parameters

ParameterResponse RequirementsRemarks
Input CurrentFull range 63A~1250A available to meet tender requirementsConfigured on project demand
Number of Branches12~126 customizable circuitsConfiguration list available
Monitoring FunctionMonitor voltage, current, power, electric energy, harmonic and temperature & humidityComplete functional list provided
Alarm ModeLocal audible & visual alarm + remote notification + dry contact outputComplete alarm mechanism
Installation MethodSupport floor-standing, rack-mounted and embedded installationSelect according to room layout
Cabinet Material≥2.0mm aluminum-zinc coated steel with epoxy powder coatingMaterial test report available
Insulation PerformanceInsulation resistance ≥ 100MΩ; 2500V/min withstand voltage without breakdownIEC 60439
EMC PerformanceComply with EN 55022 Class A with strong anti-interference abilityEMC test report available
data center display cabinet solution (8)

10. Product Solutions

10.1 Standard Solution for New Data Centers

Solution Overview: Integrated solution of modular precision RPP and DCIM system for newly-built standard data centers, realizing integrated power distribution, safety protection and energy efficiency management.

Core Configuration:

  • KITOZER modular precision RPP (400A input, 60 output circuits)
  • Dual power input + ATS automatic transfer to eliminate single point of failure
  • Class 0.2 precision monitoring module with harmonic analysis and fault location
  • DCIM system integration for remote management and PUE optimization
  • Hot-swappable modules for online expansion and maintenance

Implementation Steps: Power distribution design → Custom production → On-site installation & commissioning → System integration test → O&M training → After-sales service

10.2 Renovation Solution for Existing Computer Rooms

Solution Overview: Intelligent RPP solution for legacy computer room upgrade, compatible with existing power distribution systems to improve O&M efficiency and reliability.

Core Configuration:

  • KITOZER intelligent RPP matched with existing UPS capacity
  • Seamless connection with legacy systems without large-scale reconstruction
  • Intelligent monitoring and remote management functions
  • Fault early warning system to reduce troubleshooting time

Advantages: Reconstruction without service interruption; single unit deployed within 4 hours; protect existing investment and upgrade intelligence level efficiently.

10.3 Solution for Edge Data Centers

Solution Overview: Rack-mounted basic RPP for edge computing nodes and small computer rooms, featuring compact size, easy deployment and simple management.

Core Configuration:

  • 3U~12U rack-mounted RPP (100A input, 24 output circuits)
  • Basic protection functions; intelligent monitoring optional
  • Compact structure for space-limited environments
  • Plug-and-play for rapid deployment

Application Scenarios: Edge computing nodes, IoT gateways, branch office computer rooms and temporary IT deployment.

10.4 Solution for High-density Data Centers

Solution Overview: Combined solution of modular precision RPP and intelligent busbar system for large-scale data centers and high-density IT loads, meeting demands of high power density and rapid expansion.

Core Configuration:

  • KITOZER high-density RPP (800A input, 96 output circuits), max. 60kW load per cabinet
  • Intelligent busbar system to reduce cable routing and improve space utilization
  • Real-time monitoring for each branch to prevent overload
  • Hot-swappable modules for online expansion

Performance Advantages: Support ultra-high density loads, low line loss, accurate branch fault location, MTTR ≤ 15 minutes.

11. Application Cases

11.1 Cloud Data Center of a Large Internet Enterprise

Project Background: A large-scale cloud data center with 10,000 cabinets, requiring 99.999% high availability and rapid capacity expansion.

Solution: 800 sets of KITOZER modular precision RPP (630A input, 72 output circuits) deployed with dual UPS + ATS redundant architecture and DCIM system. Hot-swap modules enable maintenance and expansion without outage.

Effect: System availability reaches 99.999% with annual downtime ≤ 5.25 minutes; O&M efficiency increased by 70%; fault location time shortened from 4 hours to 15 minutes; PUE reduced by 0.08, saving about 12 million RMB on electricity annually.

11.2 Data Center Renovation Project of a State-owned Bank

Project Background: Legacy power distribution system with insufficient monitoring and low O&M efficiency; upgrade required without service interruption.

Solution: 120 sets of KITOZER intelligent RPP replaced, fully compatible with original UPS system. Equipped with remote monitoring and alarm system to realize 7×24 unattended operation.

Effect: Zero service interruption during renovation; O&M manpower reduced by 50% and efficiency increased by 80%; fault response time shortened from 2 hours to 15 minutes; accurate energy consumption data supports PUE optimization.

11.3 5G Core Network Computer Room of a Telecom Operator

Project Background: 5G core network computer room adopting HVDC power supply system, requiring high efficiency and stability.

Solution: 60 sets of KITOZER DC RPP (DC 336V input, 40 output circuits) deployed, equipped with precision DC monitoring, insulation monitoring and dual power redundancy design.

Effect: Power supply efficiency up to 96%, saving about 3 million RMB on electricity annually; branch fault location completed within 10 minutes; fully adapt to high-density 5G equipment and pass strict qualification tests.

12. Search Keywords, SEO & Tags

12.1 Core Search Keywords

KITOZER Remote Power Panel, Computer Room RPP Solution, Data Center RPP, Intelligent RPP, Modular RPP, Precision RPP, Dual Power RPP, RPP Monitoring System, Computer Room Power Distribution Solution, Data Center Terminal Power Distribution

12.2 SEO Optimization Keywords

RPP Brand Recommendation, RPP Technical Parameters, RPP Selection Guide, Computer Room RPP Installation Specification, Data Center RPP Standard, Difference between RPP and PDU, Introduction to Intelligent RPP Functions, Advantages of Modular RPP, RPP Troubleshooting, RPP for Green Data Center

12.3 Tags

#KITOZER #RemotePowerPanel #ComputerRoomPowerDistribution #DataCenter #IntelligentPowerDistribution #ModularDesign #PrecisionMonitoring #DualPowerRedundancy #EnergyEfficiencyManagement #GreenComputerRoom

Shopping Cart