Remote Power Panel (RPP) is the core equipment of the terminal power distribution system in data center computer rooms. It is installed at the front or end of each cabinet row, responsible for isolating, distributing, controlling and monitoring electric power output from UPS, so as to provide safe and reliable power supply for IT cabinets in rows.
Adopting modular intelligent design, KITOZER RPP integrates functions including precision power distribution, real-time monitoring, fault early warning and energy efficiency management. It serves as a key infrastructure for modern data centers to realize refined power management and high-availability power supply.
1.2 System Positioning and Functions
In the power distribution architecture of data centers, KITOZER RPP acts as the “last mile”, connecting UPS output and IT loads. Its main functions are as follows:
- Power Distribution: Distribute power from upstream UPS to PDU of each IT cabinet as required.
- Safety Protection: Provide multi-level protection against overload, short circuit, electric leakage, overvoltage and undervoltage.
- Real-time Monitoring: Precisely measure electrical parameters such as voltage, current, power, electric energy and harmonic.
- Fault Early Warning: Adopt audible & visual alarm and remote notification to quickly locate faults and reduce Mean Time To Repair (MTTR).
- Energy Efficiency Management: Collect energy consumption data to support PUE optimization and facilitate the construction of green data centers.
- Flexible Expansion: Support hot-swap and modular design to meet the dynamic capacity expansion demands of high-density IT loads.
1.3 Design Standards & Specifications
KITOZER RPP strictly complies with the following domestic and international standards:
- GB 50174-2017 Code for Design of Data Centers
- TIA-942 Telecommunications Infrastructure Standard for Data Centers
- IEC 60439-1 Low-voltage switchgear and controlgear assemblies – Part 1: General rules
- GB 7251.1 Low-voltage switchgear and controlgear assemblies – Part 1: General rules
- YD/T 1821 Environmental Requirements for Telecommunication Central Office

2. System Composition
KITOZER RPP features a modular design. Its core components and functions are listed below:
| Module Category | Core Components | Function Description |
|---|---|---|
| Cabinet Structure | 19-inch standard cabinet, aluminum-zinc coated steel plate, epoxy powder coating | IP40 protection grade, corrosion resistance, anti-electromagnetic interference and high load-bearing capacity |
| Input Unit | Main circuit breaker (ACB/MCCB), isolation transformer, surge protector | Receive power from UPS; provide short-circuit protection, electrical isolation and surge protection |
| Output Unit | Branch circuit breaker (MCB/MCCB), terminal blocks/sockets | Distribute power to IT cabinets with independent protection for each circuit; support hot swap |
| Monitoring System | Intelligent monitoring module, HMI touch screen, sensors | Collect electrical parameters in real time; support local display, remote transmission and fault alarm |
| Communication Module | RS485, TCP/IP, SNMP interface | Compatible with Modbus, BMS and DCIM systems to realize remote management |
| Auxiliary Unit | Cooling fan, indicator light, temperature & humidity sensor | Heat dissipation, status indication and ambient monitoring |
| Accessories | Copper busbar, cables, insulation parts, identification system | Ensure reliable electrical connection and operational safety |
3. System Classification
3.1 Classification by Power Supply Type
| Type | Application Scenarios | Core Features |
|---|---|---|
| AC Remote Power Panel (AC-RPP) | Traditional data centers, enterprise computer rooms | Input: AC 380V/220V; support three-phase/single-phase output, compatible with standard power supply for IT equipment |
| DC Remote Power Panel (DC-RPP) | Telecommunication computer rooms, HVDC power supply systems | Input: DC 48V/240V/336V; higher efficiency, ideal for communication equipment and high-density servers |
| AC/DC Hybrid Remote Power Panel | Environments with mixed IT loads | Provide both AC and DC output to meet power demands of different devices |
3.2 Classification by Functional Grade
| Grade | Functional Features | Application Scenarios |
|---|---|---|
| Basic RPP | Basic power distribution and protection functions | Small computer rooms, edge computing nodes and budget-limited projects |
| Intelligent RPP | Integrated monitoring and remote management functions | Medium-sized data centers and enterprise-level computer rooms requiring remote operation & maintenance |
| Precision RPP | High-precision measurement (Class 0.2), harmonic analysis and fault location | Large-scale data centers, core computer rooms of finance and telecom industries with high availability requirements |
| Modular RPP | Hot-swappable modules and rapid capacity expansion | Cloud data centers and hyper-converged architectures with dynamically changing loads |
3.3 Classification by Installation Method
- Floor-standing RPP: Independent floor installation, rated current 630A-1250A with large capacity, suitable for large-scale data centers.
- Rack-mounted RPP: Installed on 19-inch standard rack (3U-12U), space-saving, applicable to small & medium-sized computer rooms and edge data centers.
- Embedded RPP: Embedded at the end of cabinet rows with integrated design, aesthetic and space-efficient.

4. KITOZER System Configuration List
4.1 Configuration List of Basic RPP
| No. | Component Name | Model | Specifications | Quantity | Brand |
|---|---|---|---|---|---|
| 1 | Cabinet | KITOZER-RPP-800 | 800mm×600mm×2000mm, IP40, aluminum-zinc coated steel | 1 Set | KITOZER |
| 2 | Main Input Switch | KITOZER-MCCB-400 | 400A/3P, breaking capacity: 50kA | 1 Pc. | KITOZER |
| 3 | Branch Output Switch | KITOZER-MCB-32 | 32A/1P, breaking capacity: 10kA | 24 Pcs. | KITOZER |
| 4 | Surge Protection Module | KITOZER-SPD-40 | 40kA, 3-phase + N, Type 2 | 1 Set | KITOZER |
| 5 | Copper Busbar System | KITOZER-BUS-400 | 40×5mm pure copper busbar with insulation treatment | 1 Set | KITOZER |
| 6 | Indication Unit | KITOZER-IND-01 | Power indicator light, fault indicator light | 1 Set | KITOZER |
| 7 | Terminal Block | KITOZER-TER-63 | 63A, flame-retardant and insulated | 24 Sets | KITOZER |
4.2 Configuration List of Intelligent RPP (Additional to Basic Model)
| No. | Component Name | Model | Specifications | Quantity | Brand |
|---|---|---|---|---|---|
| 8 | Intelligent Monitoring Module | KITOZER-IM-02 | Class 0.5 accuracy; measure voltage, current, power and electric energy | 1 Pc. | KITOZER |
| 9 | HMI Touch Screen | KITOZER-HMI-7 | 7-inch color touch screen for local data display | 1 Pc. | KITOZER |
| 10 | Communication Module | KITOZER-COM-03 | RS485 + TCP/IP, support Modbus-RTU/TCP | 1 Pc. | KITOZER |
| 11 | Sensor Kit | KITOZER-SEN-01 | Class 0.2 current transformer, voltage sensor | 1 Set | KITOZER |
| 12 | Alarm Unit | KITOZER-ALM-02 | Audible & visual alarm, support remote notification | 1 Pc. | KITOZER |
4.3 Configuration List of Precision RPP (Additional to Intelligent Model)
| No. | Component Name | Model | Specifications | Quantity | Brand |
|---|---|---|---|---|---|
| 13 | Precision Monitoring Module | KITOZER-PM-01 | Class 0.2 accuracy, THD harmonic analysis and waveform recording | 1 Pc. | KITOZER |
| 14 | Fault Location Module | KITOZER-FL-01 | Accurate branch fault identification, positioning time < 1s | 1 Pc. | KITOZER |
| 15 | Temperature & Humidity Monitoring Module | KITOZER-ENV-01 | Accuracy: ±0.5℃, ±3%RH | 1 Pc. | KITOZER |
| 16 | Insulation Monitoring Device | KITOZER-IMD-01 | Monitor grounding insulation resistance to prevent electric leakage | 1 Pc. | KITOZER |
| 17 | Network Security Module | KITOZER-SEC-01 | Support HTTPS and data encryption to defend against network attacks | 1 Pc. | KITOZER |
5. System Schematic Diagram
5.1 Schematic Diagram of AC Intelligent RPP
UPS Output → Main Input Switch (ACB/MCCB) → Surge Protection Module → Isolation Transformer (Optional) → Copper Busbar System
→ Branch Switch (MCB/MCCB) × N → Terminal Block → IT Cabinet PDU
Intelligent Monitoring Module ← Voltage/Current Sensors ← Each Branch Circuit
HMI Touch Screen ↔ Communication Module (RS485/TCP/IP) ↔ DCIM/BMS System
Audible & Visual Alarm Unit ← Fault Detection Module
5.2 Schematic Diagram of Dual Power Redundant RPP
UPS A Output → Input Switch A → ATS Automatic Transfer Switch → Surge Protection Module → Copper Busbar System
UPS B Output → Input Switch B → ATS Automatic Transfer Switch → Surge Protection Module → Copper Busbar System
Copper Busbar System → Branch Switch × N → IT Cabinet PDU
Intelligent Monitoring Module → Remote Management System
5.3 Schematic Diagram of DC RPP
HVDC Power Supply → Input Fuse/Circuit Breaker → Surge Protection Module → DC Busbar
→ Branch Circuit Breaker × N → Terminal Block → Communication Equipment / DC Server
DC Monitoring Module ← Shunt/Hall Effect Sensor ← Each Branch Circuit
HMI Touch Screen ↔ Communication Module ↔ Power Management System

6. Product Technical Parameters
6.1 General Technical Parameters
| Parameter | Technical Index | Remarks |
|---|---|---|
| Rated Voltage | AC 380V/220V (3-phase 4-wire) / DC 48V/240V/336V | Compliant with power supply standards for IT equipment |
| Rated Frequency | 50Hz/60Hz | Compatible with different power grid standards |
| Input Current Range | 63A ~ 1250A | Selectable by model |
| Branch Current Range | 16A ~ 63A | Max. 63A load per circuit |
| Number of Branches | 12 ~ 126 circuits | Customized according to cabinet size and configuration |
| Measurement Accuracy | Voltage/Current: Class 0.2; Power/Electric Energy: Class 0.5 | Standard for precision RPP |
| Protection Grade | IP40 | Prevent dust and water droplets ingress |
| Dielectric Strength | 2500V/min, no breakdown or flashover | Comply with IEC 60439 |
| Breaking Capacity | 50kA/1s | Ensure safe cut-off under short circuit fault |
| Cabinet Dimension | 600×600×2000mm ~ 800×1000×2200mm | Floor-standing / Rack-mounted optional |
| Operating Temperature | 0℃ ~ 40℃ | Adapt to computer room environment |
| Relative Humidity | 10% ~ 90% (non-condensing) | Avoid condensation affecting insulation performance |
| Altitude | ≤2000m | Derating required for higher altitude |
6.2 Technical Parameters of Intelligent Monitoring System
| Parameter | Technical Index | Function Description |
|---|---|---|
| Monitored Items | Voltage, Current, Power, Electric Energy, Power Factor, THD, Temperature & Humidity | Full-range electrical parameter monitoring |
| Communication Interface | RS485 (Modbus-RTU), RJ45 (TCP/IP), SNMP | Integrate with mainstream management systems |
| Data Refresh Rate | 1 time/second | Real-time load status feedback |
| Alarm Mode | Audible & visual alarm, remote notification (Email/SMS), dry contact output | Multi-level fault early warning |
| Historical Data Storage | ≥ 1 year | Support energy consumption analysis and trend prediction |
| Display | 7-inch color touch screen | Local data visualization and easy operation |
| Communication Baud Rate | 9600 ~ 115200bps | Adapt to diverse communication requirements |
| Supported Protocols | Modbus-RTU/TCP, SNMPv1/v2c/v3, BACnet | Compatible with mainstream DCIM and BMS systems |
6.3 Modular Technical Parameters
| Parameter | Technical Index | Advantage Description |
|---|---|---|
| Module Type | Power distribution module, monitoring module, communication module | Independent functions, configurable on demand |
| Hot-swap Function | Support live plug & play | On-site maintenance without interrupting other loads |
| Module Replacement Time | ≤ 5 minutes | Rapid recovery and shorter MTTR |
| Expansion Capacity | Support online addition of branch modules | Adapt to dynamically changing loads |
| Module Compatibility | Universal interchange for full series modules | Reduce spare parts inventory cost |

7. Application Scope
7.1 Industry Application Scenarios
| Industry | Typical Application | Recommended Product Type |
|---|---|---|
| Internet Data Center | Cloud computing platform, large-scale data center | Modular precision RPP for high density and rapid expansion |
| Finance Industry | Bank core system, securities trading platform | Dual power redundant intelligent RPP for 99.999% high availability |
| Telecommunications Operator | Telecommunication computer room, 5G core network | DC RPP adapted for communication equipment |
| Government & Public Institution | E-government, data sharing platform | Intelligent RPP for remote O&M and energy management |
| Enterprise | ERP system, private cloud, database server | Precision RPP to ensure business continuity |
| Edge Computing | Edge data center, IoT gateway | Rack-mounted RPP for space-saving and easy deployment |
| Medical Industry | Medical imaging system, electronic medical record system | Dual power RPP complying with medical power supply safety standards |
7.2 Adaptation for Different Computer Room Types
| Computer Room Type | Features | Recommended Solution |
|---|---|---|
| New Large-scale Data Center | High density and high availability requirements | Modular precision RPP + DCIM integrated system |
| Computer Room Renovation | Upgrade existing infrastructure | Intelligent RPP compatible with legacy power distribution systems |
| Edge Computing Node | Miniaturization and distributed deployment | Basic rack-mounted RPP for rapid deployment |
| Container Data Center | Limited space and mobility requirements | Custom compact RPP for container environment |
| Green Data Center | PUE optimization and energy efficiency management | Precision RPP providing data support for PUE analysis |
8. Product Advantages
8.1 Technical Advantages
- Modular design with hot-swap function; module replacement within 5 minutes to reduce outage risks and adapt to dynamic loads.
- Class 0.2 high-precision monitoring module to capture electrical parameters accurately and support energy efficiency optimization.
- Multi-level safety protection including overload, short circuit, electric leakage, overvoltage, undervoltage and surge protection to secure IT equipment.
- Intelligent fast fault location reduces MTTR by over 70% and improves O&M efficiency.
- Compatible with mainstream protocols such as Modbus, SNMP and BACnet for seamless integration with DCIM systems.
- Redundant design for key components; MTBF ≥ 100,000 hours for high reliability.
8.2 Performance Advantages
- Optimized air duct design for efficient heat dissipation; temperature difference inside cabinet ≤ 3℃, extending service life of electronic components by 30%.
- Low harmonic distortion (THD < 3%) to minimize interference to UPS and IT devices.
- Wide input voltage range (±15% fluctuation tolerance) for unstable power grid environments.
- Fault response time < 100ms to cut off faulty circuits promptly.
- High power density; max. 126 output circuits per cabinet to meet high-density IT load demands.
8.3 O&M Advantages
- Multiple remote management methods including Web, APP and SNMP to reduce on-site work.
- Intuitive 7-inch color touch screen for easy local operation and parameter viewing.
- Auto-generated reports on energy consumption, alarms and events for data analysis.
- Predictive maintenance based on historical data and trend analysis to warn potential faults in advance.
- Excellent scalability with modular architecture to support online expansion, protect investment and lower Total Cost of Ownership (TCO).

9. Bid Specification Parameters
9.1 Core Bid Parameters
| Parameter | Bid Requirements | Reference Standard |
|---|---|---|
| Brand | Original KITOZER product; manufacturer authorization certificate required | Guarantee product quality and after-sales service |
| Modular Design | Support hot-swap; module replacement within 5 minutes without power cut | IEC 61935 |
| Measurement Accuracy | Voltage/Current ≥ Class 0.2; Power/Electric Energy ≥ Class 0.5 | GB/T 17215 |
| Breaking Capacity | Main switch ≥ 50kA; Branch switch ≥ 10kA | IEC 60947 |
| Protection Grade | ≥ IP40; third-party test report required | IEC 60529 |
| Communication Protocol | Support Modbus-RTU/TCP and SNMPv3; protocol certification required | Ensure system compatibility |
| Redundancy Design | Dual power input + ATS automatic transfer; no single point of failure | GB 50174-2017 |
| MTBF | Mean Time Between Failures ≥ 100,000 hours; manufacturer test report required | Equipment reliability specification |
| Certification | CE, UL and CQC certifications; copy of certificates required | International and domestic safety standards |
9.2 Technical Response Parameters
| Parameter | Response Requirements | Remarks |
|---|---|---|
| Input Current | Full range 63A~1250A available to meet tender requirements | Configured on project demand |
| Number of Branches | 12~126 customizable circuits | Configuration list available |
| Monitoring Function | Monitor voltage, current, power, electric energy, harmonic and temperature & humidity | Complete functional list provided |
| Alarm Mode | Local audible & visual alarm + remote notification + dry contact output | Complete alarm mechanism |
| Installation Method | Support floor-standing, rack-mounted and embedded installation | Select according to room layout |
| Cabinet Material | ≥2.0mm aluminum-zinc coated steel with epoxy powder coating | Material test report available |
| Insulation Performance | Insulation resistance ≥ 100MΩ; 2500V/min withstand voltage without breakdown | IEC 60439 |
| EMC Performance | Comply with EN 55022 Class A with strong anti-interference ability | EMC test report available |

10. Product Solutions
10.1 Standard Solution for New Data Centers
Solution Overview: Integrated solution of modular precision RPP and DCIM system for newly-built standard data centers, realizing integrated power distribution, safety protection and energy efficiency management.
Core Configuration:
- KITOZER modular precision RPP (400A input, 60 output circuits)
- Dual power input + ATS automatic transfer to eliminate single point of failure
- Class 0.2 precision monitoring module with harmonic analysis and fault location
- DCIM system integration for remote management and PUE optimization
- Hot-swappable modules for online expansion and maintenance
Implementation Steps: Power distribution design → Custom production → On-site installation & commissioning → System integration test → O&M training → After-sales service
10.2 Renovation Solution for Existing Computer Rooms
Solution Overview: Intelligent RPP solution for legacy computer room upgrade, compatible with existing power distribution systems to improve O&M efficiency and reliability.
Core Configuration:
- KITOZER intelligent RPP matched with existing UPS capacity
- Seamless connection with legacy systems without large-scale reconstruction
- Intelligent monitoring and remote management functions
- Fault early warning system to reduce troubleshooting time
Advantages: Reconstruction without service interruption; single unit deployed within 4 hours; protect existing investment and upgrade intelligence level efficiently.
10.3 Solution for Edge Data Centers
Solution Overview: Rack-mounted basic RPP for edge computing nodes and small computer rooms, featuring compact size, easy deployment and simple management.
Core Configuration:
- 3U~12U rack-mounted RPP (100A input, 24 output circuits)
- Basic protection functions; intelligent monitoring optional
- Compact structure for space-limited environments
- Plug-and-play for rapid deployment
Application Scenarios: Edge computing nodes, IoT gateways, branch office computer rooms and temporary IT deployment.
10.4 Solution for High-density Data Centers
Solution Overview: Combined solution of modular precision RPP and intelligent busbar system for large-scale data centers and high-density IT loads, meeting demands of high power density and rapid expansion.
Core Configuration:
- KITOZER high-density RPP (800A input, 96 output circuits), max. 60kW load per cabinet
- Intelligent busbar system to reduce cable routing and improve space utilization
- Real-time monitoring for each branch to prevent overload
- Hot-swappable modules for online expansion
Performance Advantages: Support ultra-high density loads, low line loss, accurate branch fault location, MTTR ≤ 15 minutes.
11. Application Cases
11.1 Cloud Data Center of a Large Internet Enterprise
Project Background: A large-scale cloud data center with 10,000 cabinets, requiring 99.999% high availability and rapid capacity expansion.
Solution: 800 sets of KITOZER modular precision RPP (630A input, 72 output circuits) deployed with dual UPS + ATS redundant architecture and DCIM system. Hot-swap modules enable maintenance and expansion without outage.
Effect: System availability reaches 99.999% with annual downtime ≤ 5.25 minutes; O&M efficiency increased by 70%; fault location time shortened from 4 hours to 15 minutes; PUE reduced by 0.08, saving about 12 million RMB on electricity annually.
11.2 Data Center Renovation Project of a State-owned Bank
Project Background: Legacy power distribution system with insufficient monitoring and low O&M efficiency; upgrade required without service interruption.
Solution: 120 sets of KITOZER intelligent RPP replaced, fully compatible with original UPS system. Equipped with remote monitoring and alarm system to realize 7×24 unattended operation.
Effect: Zero service interruption during renovation; O&M manpower reduced by 50% and efficiency increased by 80%; fault response time shortened from 2 hours to 15 minutes; accurate energy consumption data supports PUE optimization.
11.3 5G Core Network Computer Room of a Telecom Operator
Project Background: 5G core network computer room adopting HVDC power supply system, requiring high efficiency and stability.
Solution: 60 sets of KITOZER DC RPP (DC 336V input, 40 output circuits) deployed, equipped with precision DC monitoring, insulation monitoring and dual power redundancy design.
Effect: Power supply efficiency up to 96%, saving about 3 million RMB on electricity annually; branch fault location completed within 10 minutes; fully adapt to high-density 5G equipment and pass strict qualification tests.
12. Search Keywords, SEO & Tags
12.1 Core Search Keywords
KITOZER Remote Power Panel, Computer Room RPP Solution, Data Center RPP, Intelligent RPP, Modular RPP, Precision RPP, Dual Power RPP, RPP Monitoring System, Computer Room Power Distribution Solution, Data Center Terminal Power Distribution
12.2 SEO Optimization Keywords
RPP Brand Recommendation, RPP Technical Parameters, RPP Selection Guide, Computer Room RPP Installation Specification, Data Center RPP Standard, Difference between RPP and PDU, Introduction to Intelligent RPP Functions, Advantages of Modular RPP, RPP Troubleshooting, RPP for Green Data Center
12.3 Tags
#KITOZER #RemotePowerPanel #ComputerRoomPowerDistribution #DataCenter #IntelligentPowerDistribution #ModularDesign #PrecisionMonitoring #DualPowerRedundancy #EnergyEfficiencyManagement #GreenComputerRoom