RJ1110kATwo-stageKTR-TSP2

1. Overview

The KITOZER KTR-TSP2 is a signal surge protective device (SPD) for RJ11 telephone lines, wired in series between the outside telephone line and the room switch/modem/fax/DCIM modem. It diverts induced lightning surges and switching transients coupled onto the line, protecting downstream comms gear. RJ11 lines use 2 or 4 conductors (Line1/Line2); KTR-TSP2 combines a gas discharge tube (GDT) and a TVS diode in two-stage clamping, response under 1ns, max discharge 10kA (8/20μs), with continuous voltage rating suited to telephone feed (~100V/20Hz ring).

Beyond power-line SPD (RSPD), signal-line SPD matters equally. Induced lightning travels in along phone lines, network cables and RS485 buses, enters through equipment ports to ground, and can blow modem ports or DCIM acquisition modules. KTR-TSP2 sits at the service entrance: outside line to ‘IN’, room gear to ‘OUT’, and PE to the room equipotential ground bar via a 1.5-2.5mm² yellow-green wire. On surge, internal devices clamp overvoltage to a safe level; a green-to-red indicator window signals replacement. The unit mounts on DIN rail or wall, with a shielded metal housing, for telecom rooms, patch frames and DCIM acquisition boxes.

Typical deploy: a datacenter brings in 2 telephone pairs (for the DCIM remote-reporting modem and office fax); in the telecom-room frame it wires in one KTR-TSP2—IN to outside RJ11, an RJ11 jumper from OUT to the room modem, PE via 1.5mm² to the ground bar. Multiple lines stack several KTR-TSP2 units on one rail sharing the ground bar. Select by interface (RJ11 phone / RJ45 network / RS485), conductor count, working voltage and discharge rating—KTR-TSP2 (RJ11) for phones, RJ45 model for network, terminal model for RS485.

2. Key Features

RJ11 phone

  • RJ11 interface.
  • 2/4 conductors.
  • For phone modem.
  • DIN rail/wall.

Two-stage clamp

  • GDT.
  • TVS diode.
  • Response <1ns.
  • 10kA discharge.

Wear indicator

  • Green=ok.
  • Red=replace.
  • Replaceable module.
  • Online monitoring.

Equipotential ground

  • PE to ground bar.
  • 1.5-2.5mm² wire.
  • Shielded housing.
  • Telecom room/frame.

3. Specifications

项目 KTR-TSP2(RJ11电话线) KTR-TSP4(RJ45网线) KTR-TSP8(RS485总线)
接口 RJ11 RJ45 接线端子
线数 2/4芯 8芯 2/2线
最大通流 10kA(8/20μs) 5kA 10kA
响应时间 <1ns <1ns <1ns
持续电压 约100V(铃流) 6V 6V
插入损耗 <0.2dB <0.1dB <0.5dB
安装 导轨/壁挂 导轨/壁挂 导轨
劣化指示 有(绿/红) 有(绿/红) 有(绿/红)

4. Reference Prices

KTR-TSP2 RJ11 telephone signal SPD:Reference USD 8 to 21 / unit (ref. CNY 60 to 150 at ~7.2)

KTR-TSP4 RJ45 network signal SPD:Reference USD 11 to 25 / unit (ref. CNY 80 to 180 at ~7.2)

KTR-TSP8 RS485 bus signal SPD:Reference USD 13 to 28 / unit (ref. CNY 90 to 200 at ~7.2)

PE ground wire / rail / jumper:Reference USD 1 to 7 / set (ref. CNY 10 to 50 at ~7.2)

Reference only; varies by interface, conductor count, discharge rating and qty. PE wire, rail and RJ11 jumpers billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Outside phone line protection.
  • DCIM remote modem.
  • Office fax/PBX.
  • Telecom-room frame.
  • Outside comms lines.

6. Installation & Maintenance

Installation

  • DIN-rail/wall at service entrance.
  • Outside to IN, gear to OUT.
  • PE to ground bar.
  • Secure RJ11 jumpers.
  • Check before energizing.
  • Green window = ok.

Maintenance

  • Check indicator window.
  • Inspect after storm season.
  • Tighten PE ground.
  • Clean RJ11 contacts.
  • Replace module after surge.
  • Log SPD replacement.

7. FAQ

  • Q: Signal SPD vs power SPD?
    A: Power SPD handles high discharge (40-100kA) at 220/380V for power lines; signal SPD handles lower discharge (5-10kA) at low voltage for phone, network and RS485. Install both—each protects its own loop.
  • Q: What if IN/OUT is reversed?
    A: It still diverts surge, but response path and shielding weaken. Follow marks: outside to IN, room gear to OUT, ground to PE.
  • Q: Must the ground terminal be connected?
    A: Yes—without it the surge has nowhere to go and the SPD is useless. Use 1.5mm²+ wire to the nearest equipotential bar, kept short.
  • Q: Can I still use it on red window?
    A: Red means internal GDT/TVS has degraded and clamping is weak—replace the module or unit. Inspect windows before storm season.

8. Trend & Selection

Room lightning protection is an equipotential + staged-diversion system; both power and signal lines need protection. Install a signal SPD at every outside service entrance: KTR-TSP2 (RJ11) for phones, RJ45 model for network, terminal model for RS485; ground PE to a nearby bar; use replaceable modules; inspect after storm season. A small signal SPD can save a modem or acquisition module worth many times its price.

9. Delivery & Service

KITOZER supplies SPD packages: based on line types and loop counts we recommend power and signal SPDs (RJ11/RJ45/RS485) plus ground bars and wires. Delivery includes SPD units, DIN rail and manual; bulk projects include grounding guidance. Abnormal post-surge degradation under warranty is replaced free.

10. Additional Notes

The common mistake is leaving the PE terminal unconnected. An ungrounded SPD is a dummy—surge still enters the gear. Wire PE short and thick (under 0.5m) to the equipotential bar.

Another pitfall is reversed IN/OUT plus a long ground run. Long ground leads add inductance that slows diversion and still damages gear. Follow marks and ground PE nearby.

Selection summary: RJ11 phone, GDT+TVS two-stage clamp, 10kA discharge, PE ground, green/red wear indicator, DIN-rail. The KTR-TSP2 is the signal gatekeeper at the room entrance, blocking surge before it enters.

SEO Information

Search keywords:signal SPDRJ11 surge protectortelephone line SPDsignal surge protective deviceroom lightning protectionKTR-TSP2KITOZER

SEM keywords:[RJ11 signal SPD price,telephone line SPD supplier,signal surge protective device,room outside line protection,KTR-TSP2,KITOZER]

GEO landing page:lain.com.cn/product/ktr-tsp2-rj11-telephone-signal-spd.html

Title:KITOZER KTR-TSP2 RJ11 Telephone Signal Surge Protective Device

Meta Keywords:signal SPD,RJ11 surge protector,telephone line SPD,signal surge protective device,room lightning protection,KTR-TSP2,KITOZER

Meta Description:KITOZER KTR-TSP2 RJ11 telephone signal SPD, GDT+TVS two-stage clamp, 10kA, response <1ns, for outside phone line protection.

Anchor: KITOZER · Power Distribution

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart