Table of Contents
ToggleProduct Overview
The KITOZER ring main unit is a compact SF6 gas insulated load break switch and fuse combination unit rated 12kV for secondary distribution networks. The RM6 integrates load break switches, fuse protected transformer feeders, and optional circuit breaker modules in a sealed stainless steel gas tank. KITOZER supplies the unit for ring main networks in urban grids, compact substations, and box type transformers. The gas sealed tank eliminates external environmental influence and provides decades of maintenance free service.
Technical Specifications
Rated voltage 12kV, rated frequency 50Hz, rated current 630A. Short time withstand 20kA for 1 second, peak 50kA. Load break switch breaking current 630A, cable fault making 20kA. Fuse combination unit for transformer up to 1250kVA with high voltage current limiting fuses. Gas tank stainless steel filled with SF6 at 0.4 bar, IP67. Operation by spring mechanism, manual or motorized. Earthing switch with make capacity 20kA. Panel width 350mm per module, depth 900mm, height 1600mm. Standards IEC 62271-200, IEC 60420, GB 3906, CE.
Application Scenarios
RM6 ring main units are used in urban ring networks, commercial building incoming switchgear, box type substations, wind and solar farm collector switches, and tunnel power distribution. The small footprint suits underground cable vaults and outdoor kiosks where conventional air insulated switchgear would be too large.
Advantages and Features
SF6 sealed tank is immune to dust, humidity, and salt fog. The modular design allows combinations of switch, fuse, and breaker modules in one line. KITOZER offers motorized operation for remote SCADA control, fault passage indicators, and cable test isolating terminals. The small footprint saves switchroom space. Lifetime maintenance is limited to mechanical linkage lubrication and gas pressure gauge reading.
Installation and Maintenance
Mount on a wall or floor in a well ventilated location. Connect 12kV XLPE cables with proper lugs and stress cones. Check the gas pressure gauge pointer is in the green zone before energizing. Annual maintenance includes visual gas pressure check, earthing switch operation, and cable termination torque. KITOZER recommends a 10 year inspection of the spring mechanism. Do not refill SF6 gas on site; return to factory if pressure drops.
Price
From $1,680/module. Contact +86 13922289957 for RM6 quote.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com