Table of Contents
ToggleProduct Overview
KITOZER 100kW chilled-water room-level precision air handler is designed for large data centers served by a central plant with chillers. Instead of containing refrigerant within each unit, the cabinet uses a chilled-water coil fed by 7/12 degrees C primary water, removing the risk of large refrigerant charges inside the IT space. The unit includes EC plug fans, a humidifier, electric reheat, and a mixing box for outdoor air economizer integration. Water flow is modulated by a motorized control valve under controller supervision, allowing precise capacity matching across a wide load range.
Technical Specifications
Cooling capacity 100kW sensible at 7/12 degrees C chilled water, airflow 30,000 cubic meters per hour, external static pressure 300 Pa, chilled water flow 18 cubic meters per hour, water connection DN80, EC fan motor total 7.5kW, supply voltage 380V three phase, dimensions 2,200 millimeters wide by 1,400 millimeters deep by 2,400 millimeters high, weight about 950kg, G4 plus F9 filtration, humidifier 60kg per hour, reheat 30kW, 3-way modulating valve, color touch controller, Modbus TCP, SNMP, Bacnet IP, CE certified.
Application Scenarios
The 100kW chilled-water air handler is deployed in Tier-3 enterprise data centers, colocation halls, and cloud campuses where a central chiller plant provides redundancy and free cooling. It suits retrofit projects replacing older DX systems with water-based distribution. Units are typically installed in a row along the cold aisle, ducted or with open discharge, and can be grouped for N plus 1 redundancy against fan or valve failure.
Advantages and Features
Chilled-water distribution reduces on-site refrigerant charge and simplifies leak response. Central plant free cooling in winter lowers energy use dramatically. EC fans deliver high part-load efficiency and redundant airflow. The modulating 3-way valve provides smooth capacity control down to 10 percent. The controller coordinates with the BMS to optimize water temperature reset based on load, and supports alarm escalation via email or SMS gateway.
Installation and Maintenance Recommendations
Install water strainers, pressure gauges, and temperature sensors on both supply and return pipes. Insulate all water piping to prevent surface condensation. Commission water flow balance across all air handlers using balancing valves. Maintain filters quarterly, inspect valve packing annually, and clean coils with low-pressure water. Verify humidity sensor calibration every two years. Keep a spare actuator and filter set on site. Plan for condensate drain maintenance to avoid blockages.
Price
From $38,800 per unit. Contact KITOZER for AHU layout and valve selection.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com