KITOZER 60kW downflow air-cooled room-level precision air conditioner is a workhorse for medium enterprise data halls hosting 40 to 60 racks at densities of 4 to 6kW per rack. The floor-standing cabinet discharges conditioned air downward into the raised-floor plenum, from where it rises through perforated tiles into the cold aisle. Three staged scroll compressors provide capacity modulation from about 18kW up to 65kW, matching typical diurnal load swings and reducing energy waste during partial occupancy. The unit integrates a brazed plate evaporator, EC plug fan array, electronic expansion valve, electrode humidifier, and electric reheat in a double-wall insulated cabinet.
Technical Specifications
Cooling capacity 60kW sensible, airflow 18,000 cubic meters per hour, plenum static pressure up to 250 Pa, three scroll compressors R410A staged, supply voltage 380V three phase 50Hz, rated power about 22kW, dimensions 1,800 millimeters wide by 1,200 millimeters deep by 2,200 millimeters high, weight about 680kg, G4 plus F9 filtration, electrode humidifier 36kg per hour, electric reheat 18kW, color touch controller with scheduling, Modbus TCP, SNMP, Bacnet IP, alarm relays, CE certified, outdoor condenser fan speed controlled, operating ambient up to 48 degrees C.
Application Scenarios
The 60kW downflow unit is typically deployed in Tier-2 corporate data centers, government computer rooms, cloud colocation halls, and large university data centers. It pairs naturally with cold-aisle containment and perforated tile layouts. Multiple units are arranged along the perimeter of the hall for even plenum pressurization. In climates below 5 degrees C winter, the unit can be configured with low-ambient kit including head pressure control and crankcase heaters for year-round operation.
Advantages and Features
Staged compressor control delivers efficient part-load operation and smooth temperature hold within 1 degree C. EC fans with automatic static pressure compensation reduce fan energy as filters load. The controller supports up to 16 units in a group, rotating runtime evenly and triggering backup units on a failure. Hot-aisle or cold-aisle containment integration improves cooling efficiency by eliminating bypass air. The cabinet is designed for front service access, reducing required side clearance to 300 millimeters.
Installation and Maintenance Recommendations
Verify raised-floor structural capacity, since a fully loaded 60kW cabinet can weigh over 700kg plus water. Seal all plenum penetrations and balance tile layout. Place the outdoor condenser on a shaded rooftop pad at least 3 meters from walls, with refrigerant line lengths under 50 meters. Commission airflow and temperature at design load. Maintenance includes quarterly filter changes, annual coil cleaning, bi-annual refrigerant leak check, and yearly electrical torque verification. Keep spare contactors, expansion valve, and humidifier cartridge on site.
Price
From $24,800 per unit. Contact KITOZER for full plant layout and condenser selection.