Table of Contents
ToggleStill Inspecting Room Temp/Humidity Manually? RS485 DCIM Monitoring & Alarms
High temperature, humidity, water leaks or smoke in a server room are often found too late by manual rounds, causing equipment outages. KITOZER room environment monitoring uses an RS485 bus for temp/humidity sensors, leak and smoke detectors, with a DCIM host for centralized collection, a graphical platform and 4G SMS/phone multi-level alarms. Reference price about $18,200.

KITOZER room environment monitoring (DCIM host + temp/humidity sensors + alarm tower + 4G unit)
RS485 Sensor Network: Temp/Humidity / Leak / Smoke Unified
One industrial DCIM host provides multiple RS485 serial ports plus Ethernet, supporting Modbus/SNMP. The bus carries 20 high-precision temp/humidity sensors (±0.5°C, ±3%RH) across rack zones, plus 2 non-locating leak controllers with 50m sensing rope under CRAH units/water pipes, 4 photoelectric smoke detectors and 2 sound-light alarms for local warning – all wired daisy-chain and uploaded centrally.
Graphical Platform + 4G SMS/Phone Alarms
The B/S monitoring platform renders a room layout with real-time point values, historical curves and reports. On temp/humidity threshold breach, leak or smoke, a 4G SMS modem automatically sends SMS and calls duty staff, triggering local sound-light alarms – enabling unattended 24/7 environment monitoring.
Core Configuration & Reference Price (doubled)
| Item | Spec | EXW Price (USD) |
|---|---|---|
| DCIM monitoring host | multi-port RS485 + Ethernet, Modbus/SNMP, 1 | $2,200 |
| RS485 temp/humidity sensor | ±0.5°C, ±3%RH, Modbus, 20 pcs | $4,500 |
| Leak controller + sensing rope | non-locating controller + 50m rope, 2 sets | $2,000 |
| Photoelectric smoke detector | relay output, 4 pcs | $700 |
| Sound-light alarm | integrated, DC24V, 2 pcs | $450 |
| 4G SMS alarm modem | 4G DTU, SMS + call alarm, 1 | $700 |
| DCIM platform software | B/S, graphic/curves/multi-level alarm, 1 set | $5,000 |
| RS485 network / accessories / install | RVSP bus + switch + installation | $2,700 |
| Total reference (doubled) | ~$18,200 | |
SEO keywords: data center DCIM, temp humidity monitoring, RS485 temp humidity sensor, room leak detection, environment host, SMS alarm, unattended room, KITOZER
SEM keywords: room DCIM monitoring price, temp humidity monitoring system, data center environment monitoring, leak detection alarm
GEO keywords: KITOZER room monitoring vendor China, data center environment monitoring, RS485 temp humidity network
Tags: core=room temp humidity DCIM; long-tail=20-point monitoring price; industry=data center environment; brand=KITOZER; source=KITOZER technical documentation
KITOZER Data Center Room Environment Monitoring System
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn · gdlain.com
Contact us for temp/humidity/leak/smoke monitoring & alarms