KITOZER
KITOZER

KITOZER rope leak detection locate cable

KITOZER KTR-LR Rope-type Locating Leak Detection System

Brand: KITOZER Series: KTR-LR Category: Environmental Monitoring / Leak Detection

Locating rope1 m accuracyRS485Relay outKTR-LR

1. Overview

The biggest hazard in a room is not power loss — it is water. Condensate from precision AC, chilled-water pipes, fire mains and slab leaks can flood server racks, causing losses measured in millions. Leak detection comes in two kinds: non-locating (a cable alarms only that the segment is wet, not where) and locating (reports the exact distance, accurate to 1 m). A rope-type locating system consists of a sensing cable and a controller: the cable runs under AC units and along water pipes, and the controller tracks resistance changes along it. Water touching the cable triggers an alarm with the distance.

The KTR-LR series offers locating sensing cable (max 100 m per run, accuracy ±1 m) and non-locating cable (lower cost, alarm only). The controller shows leak location on an LCD, uploads via RS485 (Modbus-RTU) to the environment platform, and has 2 relay outputs (sounder and exhaust fan). The cable is chemical-resistant, cut-to-length, and reusable (wiped dry after a leak). Suitable under precision AC, in water-pipe trenches and under raised floors.

Selection: locating or not (critical pipes and AC need locating for fast repair; secondary areas use non-locating to save cost); cable length (match run, ≤100 m per segment); output (RS485 to environment platform, or relay with sounder for standalone). Leak rope is consumable — sensitivity drops after repeated exposure, replace every 3~5 years.

2. Key Features

Detection

  • Locating accuracy ±1 m
  • Max run 100 m
  • Response time ≤3 s
  • Chemical-resistant, cuttable

Controller

  • LCD shows leak distance
  • RS485 Modbus-RTU upload
  • 2 relay outputs (sounder/fan)
  • 1 digital input (reset)

Reliability

  • Reusable cable, wipe to reset
  • DC 9~36 V wide-range supply
  • DIN-rail / wall mount
  • -10~60℃ operating

3. Specifications

Item KTR-LR-NP KTR-LR-P
Type Non-locating Locating
Accuracy Alarm only ±1 m
Max cable 100 m/run 100 m/run
Response ≤3 s ≤3 s
Comms Relay RS485 + relay
Display LED LCD
Power DC12V DC 9~36V
Typical use Secondary areas/tight budget Under AC / pipe runs

4. Reference Prices

KTR-LR-NP non-locating controller (with 10 m rope):Reference USD 42~83 / set (ref. CNY 300~600 at ~7.2)

KTR-LR-P locating controller (with 10 m rope, LCD):Reference USD 111~208 / set (ref. CNY 800~1,500 at ~7.2)

Locating sensing rope (per meter):Reference USD 2~3.5 / m (ref. CNY 15~25 at ~7.2)

Non-locating sensing rope (per meter):Reference USD 1~2 / m (ref. CNY 8~15 at ~7.2)

Reference only; priced by length and locating type. 1-year warranty. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Under CRAC indoor unit condensate pans.
  • Chilled and cooling water pipe trenches.
  • Under raised access floors.
  • Fire mains and humidifier water lines.
  • Kitchen and pantry wet areas.

6. Deployment & Implementation

Installation

  • Lay rope under the AC drip pan
  • Clip to pipe runs every 1 m
  • No knots; do not immerse the cable
  • Mount controller on wall or DIN rail, away from water

Operations

  • Quarterly simulate with wet tissue
  • Check for rodent damage and wear
  • After a leak, wipe rope — auto reset
  • Replace aged rope every 3~5 years

7. FAQ

  • Q: Is locating worth the extra cost?
    A: Locating costs 2~3× more, but reports the leak within 1 m — no need to tear up floors to hunt. Use locating under AC and main pipes; non-locating for secondary corridors and tight budgets.
  • Q: Can the rope sit in water?
    A: No. The rope detects surface water film; prolonged immersion corrodes the electrodes and shortens life. Lay it along the drip path; alarm when water touches, then drain promptly.
  • Q: What if rodents chew the cable?
    A: The broken segment stops alarming. Splice with connectors or trim and rejoin. The controller reports open-circuit.
  • Q: Can it connect to the environment platform?
    A: Yes. RS485 Modbus-RTU plugs into mainstream environment hosts (including KTR-8DCU); standalone sites use relay to a sounder.

8. Trend & Selection

Leak detection is moving from non-locating rope to a fusion of locating rope, fiber temperature sensing and visual AI. Locating accuracy is improving from meter to decimeter. AI video spotting of condensate stains and floor water is emerging. Leak detection is now mandatory under GB50174 room design code. Select: locating for critical areas, non-locating for secondary, and wire the controller into the environment system. The rope is insurance — silent until a big event.

9. Delivery & Service

KITOZER offers KTR-LR selection by locating type, cable length (10~100 m) and output (RS485/relay). Each set ships with controller, sensing cable, clips and power adapter. Test report and manual included. 1-year warranty; batch projects can add sounders, solenoid valves and drain-pump interlock.

10. Additional Notes

The #1 mistake is laying the rope on dry ground. For neatness the rope runs along the wall, but AC condensate never reaches it — useless. Lay it at the lowest point of the drip path so water flows over the rope.

The second pitfall is no reset after a leak. Water cleared but the controller still alarms because auto-reset time is too long. Set auto-reset to 30 s so wiping clears it.

The third blunder is never simulating. Installed and forgotten, then a real leak finds the rope broken, controller unpowered or RS485 unplugged. Quarterly wet-tissue test confirms the whole alarm chain.

Selection summary: locating for critical, non-locating for secondary, rope at the drip low point, quarterly simulation. Leak detection is the flood wall of the room — invisible daily, but one leak saves ten years of rope cost.

SEO Information

Search keywords:KTR-LRKITOZERLocating Leak Detection Rope

SEM keywords:leak detection rope,locating leak sensor,rope leak detection,data center leak,leak controller,KTR-LR,KITOZER

GEO landing page:lain.com.cn/product/ktr-lr-leak_detection_rope.html

Title:KITOZER KTR-LR Rope-type Locating Leak Detection System

Meta Keywords:leak detection rope,locating leak sensor,rope leak detection,data center leak,KTR-LR,KITOZER

Meta Description:KITOZER KTR-LR rope-type locating leak detection, 1 m accuracy, sensing cable + controller, RS485/relay, under CRAC and along water pipes.

Anchor: KITOZER by Guangzhou Laian · Leak Detection Rope

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart