Table of Contents
ToggleProduct Overview
KITOZER 30kW row-level air conditioner sits directly in the rack row between server cabinets, delivering cooling exactly where heat is generated. This in-row architecture eliminates long hot-air travel paths and allows rack densities to rise from 5kW to 15kW or more without raising room-level airflow. The unit is the same width as a standard rack (600 millimeters) and fits seamlessly into cold-aisle or hot-aisle containment. A front-facing intake draws in hot exhaust air from the rack aisle, while the discharge side blows cold air into the cold aisle, completing a short, efficient cycle.
Technical Specifications
Cooling capacity 30kW sensible, airflow 9,000 cubic meters per hour, EC plug fan, scroll compressor R410A, supply voltage 380V three phase 50Hz, rated power about 11kW, dimensions 600 millimeters wide by 1,200 millimeters deep by 2,000 millimeters high, weight about 280kg, G4 plus F9 filtration, humidifier 9kg per hour, touch controller on front door, Modbus TCP, SNMP, Bacnet IP, alarm relay, CE certified, front and rear service access.
Application Scenarios
In-row 30kW units are the standard choice for high-density computing clusters, GPU training racks, storage arrays, and edge colocation sites. They are used in hybrid facilities where most racks remain at 5kW but a few clusters run at 10 to 15kW. The row-level approach avoids overcooling the entire room for a few hot racks and supports phased upgrades as density grows. Units can be air-cooled with remote condensers or water-cooled for maximum density.
Advantages and Features
Localized cooling eliminates hot spots and reduces fan energy. Front-door controller gives technicians immediate access without entering the cold aisle. EC fans modulate speed based on aisle temperature, saving energy. The unit shares a common rack footprint, simplifying containment geometry. Multiple units in a row load-share and provide redundancy; if one faults, adjacent units pick up the load.
Installation and Maintenance Recommendations
Position the in-row unit in the middle of the rack bank for even aisle coverage. Seal gaps between units and containment panels. Connect condensate drain with an air break. Commission aisle temperature sensors and verify fan modulation under load. Maintenance includes quarterly filter replacement, annual condenser cleaning, and bi-annual compressor inspection. Keep spare filters on site.
Price
From $11,800 per unit. Contact KITOZER for row layout and redundancy calculation.