ToggleKITOZER KTR-TH14 RS485 Temperature Humidity Sensor with Display
Brand: KITOZER Series: KTR-TH14 Category: Environmental Monitoring / Sensors
Temp/humidityRS485 ModbusLCD displayKTR-TH14

1. Overview
KITOZER KTR-TH14 is a datacenter temperature and humidity sensor with RS485 Modbus-RTU and an LCD local display, measuring ambient temperature and humidity and uploading to the DCIM. Datacenters are sensitive: high temperature throttles or shuts servers, low humidity causes ESD, high humidity causes condensation. The sensor is the room’s thermometer and hygrometer.
KTR-TH14 uses a high-accuracy digital sensor: temperature -20 to 60C, accuracy ±0.3C; humidity 0 to 100%RH, accuracy ±3%RH. The LCD shows both at once; keys set alarm thresholds and comms. RS485 Modbus-RTU, baud 1200 to 115200, address 1 to 255. Powered DC 12 to 24V, wall-mount, built-in or remote probe.
Widely used in datacenter rooms, UPS and battery rooms, telecom closets, archives and warehouses. Typical deploy: wall-mount in the room center at 1.5m, RS485 daisy-chain to the DCIM acquisition module. Above 25 to 27C or outside 40 to 60%RH, the DCIM pops up and links the A/C. Battery rooms also monitor temperature to prevent overheating.
2. Key Features
High accuracy
- Temp -20 to 60C.
- ±0.3C accuracy.
- Humidity 0 to 100%RH.
- ±3%RH accuracy.
RS485 Modbus
- Modbus-RTU protocol.
- Baud 1200 to 115200.
- Address 1 to 255.
- Daisy-chain bus.
LCD display
- LCD shows temp and humidity.
- Keys set thresholds and address.
- Local view without platform.
- Parameters persist.
Flexible mount
- Wall-mount.
- DC 12 to 24V.
- Built-in or remote probe.
- Compact on wall.
3. Specifications
| Item | KTR-TH14 | KTR-TH08 |
|---|---|---|
| Temp range | -20 to 60C | -10 to 50C |
| Temp accuracy | ±0.3C | ±0.5C |
| Humidity range | 0 to 100%RH | 0 to 100%RH |
| Humidity accuracy | ±3%RH | ±5%RH |
| Comms | RS485 Modbus | RS485 Modbus |
| Display | LCD | None |
| Power | DC 12 to 24V | DC 12 to 24V |
| Mount | Wall | Wall/DIN |
4. Reference Prices
KTR-TH14 temp/humidity sensor (RS485, LCD): Reference USD 28 to 83 / pc (ref. CNY 200 to 600 at ~7.2)
KTR-TH08 economy (no display): Reference USD 14 to 42 / pc (ref. CNY 100 to 300 at ~7.2)
Reference only; price varies by accuracy, probe type and quantity. DCIM module and 485 converter billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Datacenter room temp/humidity.
- UPS and battery room temperature.
- Telecom closets and shafts.
- Archives and libraries.
- Warehouse and lab environment.
6. Installation & Maintenance
Installation
- Wall-mount in room center at 1.5m.
- Avoid supply vents, heat sources and doors.
- Daisy-chain RS485 to acquisition module.
- Power DC 12 to 24V.
- Set address and baud rate.
- Test upload on the platform.
Maintenance
- Compare with a reference gauge quarterly.
- Clean probe dust.
- Check RS485 wiring and terminator.
- Recalibrate or return if drift over 0.5C.
- Log alarms and actions.
- Prioritize battery-room temperature.
7. FAQ
- Q: What is the datacenter temp/humidity standard?
A: ASHRAE A1 recommends 22 to 24C and 40 to 60%RH; Chinese rooms often run 23 to 27C and 40 to 60%RH. Too hot throttles; too cold wastes energy; too dry causes ESD; too wet causes condensation. - Q: Why daisy-chain RS485?
A: Daisy-chain minimizes signal reflection for stable comms. Star or branch wiring causes reflections and unreliable links. Fit a 120-ohm terminator at the bus end. - Q: Where to place the sensor?
A: Room center at 1.5m, away from supply vents and heat sources, representing average ambient. Not against a wall or in a corner, which misrepresents server inlet. High-density rows also measure cold-aisle inlet. - Q: How many sensors per DCIM?
A: One RS485 bus supports 32 devices (128 with repeaters). Unique addresses, daisy-chained. A 100sqm room needs 4 to 8 points.
8. Trend & Selection
Sensors are moving from single measurement to multi-parameter integration: combined leak, smoke, access and current probes; wireless LoRa to cut wiring; and AI prediction of A/C load. RS485 remains the room-DCIM mainstream. Choose accuracy no worse than ±0.3C; LCD local display; RS485 Modbus; daisy-chain; 120-ohm end resistor; quarterly calibration; prioritize battery-room temperature.
9. Delivery & Service
KITOZER supplies environmental-monitoring packages: based on room area and point count, we recommend sensor models and acquisition modules. Bundled with DCIM host, A/C, leak and smoke. Delivery includes sensor, probe and manual; bulk orders include on-site commissioning. Warranty covers replacement.
10. Additional Notes
The most common error is aiming the sensor at a supply vent. Vent temperature is the A/C outlet, not the room. Place it between hot and cold aisles at server-inlet height to measure what the gear actually feels.
Another pitfall: using network cable in a star for RS485. RS485 needs shielded twisted pair daisy-chained, not star. Use at least 0.75mm², under 1200m, with a 120-ohm end resistor.
Selection summary: temp accuracy ±0.3C; RS485 Modbus; LCD; DC 12 to 24V; daisy-chain; 120-ohm end resistor; quarterly calibration. The sensor is the room’s thermometer; accurate measurement lets A/C and DCIM hold the comfort zone.
SEO Information
Search keywords:temp humidity sensorRS485 humiditydatacenter monitoringModbus sensordisplay humidity sensorDCIM sensorKTR-TH14KITOZER
SEM keywords:[‘temp humidity sensor price,RS485 humidity supplier,datacenter monitoring,Modbus temp humidity,display humidity sensor,KTR-TH14,KITOZER’]
GEO landing page:lain.com.cn/product/ktr-th14-rs485-temp-humidity-sensor-display.html
Title:KITOZER KTR-TH14 RS485 Temperature Humidity Sensor with Display
Meta Keywords:temp humidity sensor,RS485 humidity,datacenter monitoring,Modbus sensor,display humidity sensor,DCIM sensor,KTR-TH14,KITOZER
Meta Description:KITOZER KTR-TH14 datacenter temp/humidity sensor, RS485 Modbus, LCD display, temp accuracy ±0.3C, humidity ±3%RH, for DCIM environmental monitoring.
Anchor: KITOZER · Environmental monitoring
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com