ToggleKITOZER KTR-TH7 Data-Center Temp/Humidity Sensor with RS485 Display
Brand: KITOZER Series: KTR-TH7 Category: Environmental Monitoring / Temp & humidity
RS485 ModbusLED display+/-0.3CWall mountDCIM integration
1. Overview
Data centers target 23 +/-1 C and 40 to 60% RH. Out-of-range conditions cause server throttling, condensation shorts or ESD damage. Temp/humidity sensors sample the room continuously and upload readings over RS485 to the DCIM platform; on alarm they trigger the AC or annunciate. A sensor with a large LED display lets staff see values at a glance in corridors or in front of racks.
The KITOZER KTR-TH7 is a data-center temp/humidity sensor using an imported Sensirion digital probe. Temperature accuracy +/-0.3 C (-10 to +60 C), humidity accuracy +/-2% RH. Large LED display shows temp and humidity. RS485 Modbus RTU at 9600/19200, address 1 to 247. Powered by DC12V/24V. Wall-mount ABS housing; probe is internal or on a 1.5 m extension. Alarm thresholds are set via keys; over-threshold triggers a relay output. Operating temp -20 to +60 C.
Selection confirms: accuracy (industrial grade +/-0.3 C / +/-2% RH), whether a display is needed, communication (RS485/Ethernet), remote probe, and power (DC12V/24V). Generally one sensor per 200 to 400 m2, placed in both hot and cold aisles. RS485 daisy-chain reaches 1200 m.
2. Key Features
Sensing accuracy
- Sensirion digital probe.
- Temp accuracy +/-0.3 C.
- Humidity accuracy +/-2% RH.
- Response time <=8 s.
Display and communication
- Large LED numeric display.
- RS485 Modbus RTU.
- Baud 9600 / 19200.
- Address 1 to 247.
Structure and alarm
- Wall-mount ABS housing.
- Internal probe or 1.5 m remote.
- Threshold set via keys.
- Over-threshold relay output.
3. Specifications
| Item | KTR-TH7 Temp/Humidity Sensor |
|---|---|
| Parameters | Temperature + humidity |
| Temp accuracy | +/-0.3 C (-10 to +60 C) |
| Humidity accuracy | +/-2% RH |
| Temp range | -20 to +60 C |
| Humidity range | 0 to 100% RH |
| Display | Large LED numeric |
| Communication | RS485 Modbus RTU |
| Baud rate | 9600 / 19200 |
| Address | 1 to 247 |
| Power | DC12V/24V |
| Probe | Internal or 1.5 m remote |
| Alarm output | Dry relay contact |
4. Reference Prices
KTR-TH7 temp/humidity sensor (LED display): Reference USD 42~83 (ref. CNY 300~600 at ~7.2)
KTR-TH7 temp/humidity sensor (basic no display): Reference USD 21~42 (ref. CNY 150~300 at ~7.2)
KTR-TH7 remote probe extension (per meter): Reference USD 1.4~2.8 (ref. CNY 10~20 at ~7.2)
Reference only; final quote applies. 1-year warranty. Bulk pricing available. RS485 to DCIM integration. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Cold/hot aisle monitoring in data centers.
- Power rooms and battery rooms.
- Archive and storage room monitoring.
- Lab and workshop logging.
- Base stations and outdoor cabinets.
6. Installation & Maintenance
Installation
- Wall-mount at 1.5 m height.
- Avoid AC outlets and direct sun.
- Daisy-chain RS485 to DCIM.
- Power DC12V/24V.
- Set address, baud, alarm thresholds.
- Calibrate readings on the platform.
Maintenance
- Calibrate annually against a standard source.
- Clean probe filter.
- Re-tighten RS485 terminals.
- Check LED brightness.
- Simulate alarm test.
7. FAQ
- Q: How many sensors per room?
A: Generally one per 200 to 400 m2, with points in both hot and cold aisles. Large rooms are zoned. - Q: Can the probe go inside a rack?
A: Use a remote probe extension; place the probe at rack inlet and hang the display on the wall. This measures rack inlet conditions. - Q: How many sensors on one RS485 bus?
A: Without repeater, 32 units; with 485 repeater, up to 128. Data centers typically use 10 to 20. - Q: What happens on out-of-range?
A: Link to precision AC for temp/humidity control; relay output to alarm. The platform logs over-threshold curves for AC capacity analysis.
8. Trend & Selection
Environment monitoring trends toward networked, visual panels integrated with DCIM; LED displays aid walkthroughs. Choose industrial-grade +/-0.3 C; RS485 Modbus; LED display; place in hot and cold aisles; calibrate annually. It is the thermometer of the data center.
9. Delivery & Service
KITOZER supplies KTR-TH7 sensors including unit, power adapter, mounting bracket and certificate. Remote probes are supplied per meter. DCIM integration and commissioning are provided.
10. Notes
A common pitfall is mounting at an AC outlet. Outlet temperature is biased low and does not represent the room. Mount mid-aisle or in the return path.
Another pitfall is skipping calibration. After 1 to 2 years the probe drifts. Calibrate annually against a standard source.
Selection summary: +/-0.3 C / +/-2% RH; LED display; RS485 Modbus; DC12V/24V; relay alarm. It monitors the room in real time and alarms on over-range.
Systemically, one over-temperature event can throttle or crash a row of servers. The sensor costs a few hundred CNY and is the foundation of environment monitoring.
Cost-wise, a 2000 m2 room with 10 sensors totals about 5000 CNY — the smallest line item in the DCIM system.
SEO Information
Search keywords: KITOZER
SEM keywords: temperature humidity sensor, RS485 sensor, LED display, data-center environment monitoring, DCIM sensor, KTR-TH7, KITOZER
GEO landing page: lain.com.cn/product/431_temp_hum_7.html
Title: KITOZER KTR-TH7 Data-Center Temp/Humidity Sensor with RS485 Display
Meta Keywords: temperature humidity sensor, RS485 sensor, LED display, data-center environment monitoring, KTR-TH7, KITOZER
Meta Description: KITOZER KTR-TH7 data-center temp/humidity sensor, RS485 Modbus, large LED display, accuracy +/-0.3C / +/-2%RH, for environment monitoring.
Anchor: KITOZER · KITOZER Products
Contact Us
KITOZER Brand
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP:+86 19068534140
Web: lain.com.cn | gdlain.com