KITOZER RS485 Temperature Humidity Sensor Modbus For Server Room

Product Overview

The KITOZER RS485 temperature and humidity sensor is a wall-mounted environmental probe designed for server rooms, electrical cabinets, warehouses, clean rooms, museum galleries, and cold storage areas. The probe combines a high-precision digital sensing element with an RS485 Modbus RTU output, allowing up to 32 units to be daisy-chained on a single twisted pair back to a KITOZER environment monitoring host or BMS. The white ABS enclosure with a ventilation grille protects the sensing element from direct dust exposure while allowing air to circulate freely around the sensor chip, ensuring fast response to temperature and humidity changes.

A built-in 0.96 inch OLED display on selected variants shows the current temperature and humidity readings locally, so maintenance staff can verify readings without a laptop. The sensor is powered from a 9 to 24 V DC supply, and a lightning protection circuit on the RS485 terminals protects the host from surge damage caused by long cable runs between buildings. The Modbus register map is openly documented, allowing integration into third-party PLC, SCADA, and building management systems without a proprietary driver.

Technical Specifications

Temperature range minus 40 degrees Celsius to 80 degrees Celsius, accuracy plus or minus 0.3 degrees Celsius at 25 degrees Celsius, resolution 0.01 degrees Celsius. Humidity range 0 to 100 percent relative humidity, accuracy plus or minus 2 percent RH at 25 degrees Celsius, resolution 0.01 percent RH. Sensor element calibrated digital chip with 16 bit ADC. Interface RS485, Modbus RTU protocol, baud rate 9600 to 115200 bps selectable, default 9600 8N1. Address 1 to 247 configurable via DIP switch or software. Supply voltage 9 to 24 V DC, typical current 30 mA. Operating temperature minus 40 degrees Celsius to 80 degrees Celsius. Enclosure ABS white, dimensions 86 by 86 by 28 millimeters, wall mount. Cable lead 1 meter standard, extension up to 1200 meters on RS485 bus. CE and RoHS certified, two year warranty.

Application Scenarios

This sensor is installed on server room walls at the cold aisle return air path, on top of electrical switchgear cabinets, inside telecom equipment shelters, along warehouse storage aisles, inside pharmaceutical cold rooms, in museum climate-controlled display galleries, and on library basement walls to detect rising humidity. In a typical data center deployment, three to six sensors are placed at different heights and positions to map the temperature gradient, and the monitoring host raises an alarm when any sensor reads above 27 degrees Celsius or below 18 degrees Celsius, or when relative humidity exceeds 60 percent or drops below 40 percent. In cold storage applications, the sensor is installed at the warmest point inside the room to confirm that the refrigeration setpoint is maintained throughout the storage volume.

Key Advantages

The first advantage is measurement accuracy. The plus or minus 0.3 degrees Celsius temperature accuracy and plus or minus 2 percent RH accuracy meet the requirements of ASHRAE TC 9.9 for data center monitoring, allowing the sensor to be used as evidence in compliance audits. The second advantage is long cable distance. RS485 differential signaling supports up to 1200 meters of cable, so sensors spread across a large factory floor or multi-building campus can be collected on one bus without repeaters. The third advantage is open protocol. Modbus RTU on documented registers means the sensor can be read by any PLC or SCADA package, and customers are never locked into a single monitoring vendor. The fourth advantage is surge protection. The on-board TVS diode and gas discharge tube on the RS485 terminals clamp transients caused by nearby lightning strikes, reducing sensor and host failure rates on exposed outdoor runs.

Installation and Maintenance Recommendations

Mount the sensor at a height of 1.5 meters above the floor, away from direct sunlight, away from air conditioning outlets, and away from door openings that cause transient drafts. Use shielded twisted pair cable for the RS485 bus, daisy-chain sensors rather than star wiring, and install a 120 ohm termination resistor at the last sensor on the bus. Set each sensor to a unique Modbus address using the DIP switch and record the address map in the project documentation. During commissioning, compare the sensor reading against a calibrated reference thermometer and adjust the offset register if the deviation exceeds 0.5 degrees Celsius. Schedule annual calibration checks using a reference humidity chamber, and clean the ventilation grille with a soft brush if dust accumulates. Avoid installing the sensor near devices that radiate heat, such as power supplies, UPS units, or laser printers, because the local temperature will not represent room average conditions. When multiple sensors are installed on the same RS485 bus, use a common ground wire between the host and all sensors to eliminate ground loop noise that can corrupt Modbus frames. The sensor also supports a software calibration command, so the offset can be adjusted remotely from the monitoring host without climbing a ladder to press physical buttons.

Price

From $45 per unit, including 1 meter cable. OLED display variant from $65. Contact +86 13922289957 for bulk pricing and calibration certificate options.