ToggleKITOZER KTR-TH23 RS485 Temperature Humidity Transmitter (Wall-mount)
Brand: KITOZER Series: KTR-TH23 Category: Environmental Monitoring / Temp Humidity Transmitter
RS485temp & humidityModbuswall-mountKTR-TH23

1. Overview
The KITOZER KTR-TH23 is a wall-mount temperature and humidity transmitter measuring ambient temperature and relative humidity, outputting data over an RS485 bus using Modbus-RTU. Multiple units can be paralleled on one 485 bus and read by an environmental monitoring host or acquisition module for multi-point monitoring.
It uses a digital temp/humidity sensor with about ±0.3℃ temperature accuracy and ±2%RH humidity accuracy, with stable response. The wall-mount ABS enclosure mounts on a wall or cabinet inner panel, away from AC outlets and heat sources so it reads the true ambient climate.
In data center and power room monitoring, temperature and humidity are mandatory: excessive heat affects cooling, low humidity raises static risk, and high humidity risks condensation. The KTR-TH23 works with the monitoring platform for real-time curves, out-of-range alarms and AC interlock, serving as a basic acquisition node.
Place representative points by the room thermal pattern: rack intake, between cold and hot aisles, and separate points in the power room and battery room, not clustered in one corner. Daisy-chain the 485 bus, add terminators at both ends, and ground the shield at one end to suppress mains interference for stable long-distance multi-point readings.
2. Key Features
RS485 Modbus
- Parallel multi-point on 485.
- Modbus-RTU protocol.
- Connects to monitoring host/module.
- Hand-in-hand 485 wiring.
Temp & humidity
- Temperature ±0.3℃.
- Humidity ±2%RH.
- Stable digital sensor.
- Real-time curves.
Wall-mount
- ABS wall enclosure.
- Mount on wall/cabinet panel.
- Avoid outlets and heat.
- Flexible placement.
Threshold alarms
- Set temp/humidity limits.
- Upload out-of-range alarms.
- AC interlock.
- Long-term acquisition.
3. Specifications
| Item | Parameter |
|---|---|
| Parameters | temperature + relative humidity |
| Temp accuracy | ±0.3℃ |
| Humidity accuracy | ±2%RH |
| Interface | RS485 (Modbus-RTU) |
| Power supply | 12~24V DC |
| Current | ≤30mA |
| Temp range | -20~60℃ |
| Humidity range | 0~100%RH |
| Mounting | wall-mount |
| Baud rate | 9600~115200 bps |
4. Reference Prices
KTR-TH23 RS485壁挂温湿度变送器(单只): Reference USD 12~22 / pc (ref. CNY 85~160 at ~7.2)
KTR-TH23 采集套装(变送器+485采集模块+电源): Reference USD 36~67 / kit (ref. CNY 260~480 at ~7.2)
Reference only; priced per pc. Monitoring platform and software excluded.. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Data center temp/humidity monitoring.
- Power room environmental monitoring.
- In-rack temp/humidity acquisition.
- Warehouse/archive monitoring.
- Multi-node 485 networking.
6. Installation & Maintenance
Installation
- Mount on wall or cabinet panel.
- Avoid AC outlets and heat.
- Daisy-chain the 485 bus.
- Set a distinct device address.
- Unify baud rate and protocol.
- Set temp/humidity alarm limits.
Maintenance
- Calibrate the probe periodically.
- Clean the sensor dust cover.
- Check 485 wiring and terminator.
- Verify no address conflicts.
- Spot-check platform readings.
- Replace contaminated probes.
7. FAQ
- Q: How many units on one 485 bus?
A: Standard 485 supports up to 32; practically use 16~32 with a terminator and keep the run under 1200 m. - Q: vs analog transmitter?
A: RS485 digital is noise-immune and networkable for multi-node; analog (4-20mA) needs a separate run per unit to an acquisition card, costing more. - Q: Large reading deviation?
A: First check whether it sits near an outlet or heat source, then calibrate against a reference source and replace a contaminated probe. - Q: 5V or 24V supply?
A: The KTR-TH23 runs 12~24V DC; choose by the acquisition module supply and watch polarity and common ground.
8. Trend & Selection
Environmental monitoring moves toward multi-point networking and smart interlock; low-cost, easy-to-network RS485 Modbus transmitters remain the mainstay for data center temp/humidity acquisition. Size points by monitoring nodes, unify addresses and baud rate, mount away from direct airflow and heat, and calibrate regularly for trustworthy data.
9. Delivery & Service
KITOZER selects the KTR-TH23 per the room and power-room layout, supplying transmitters, a 485 acquisition module and power with wiring notes. Delivery includes the transmitter, mounting backplate and terminals. Warranty covers address assignment and alarm interlock commissioning.
10. Additional Notes
A common pitfall is mounting directly under an AC outlet. The sensor reads cold, distorted air, so the AC wrongly thinks it is not hot and stops cooling while racks run hot. Mount at a representative return-air or mid-rack position.
Another pitfall is 485 address conflicts. Identical addresses scramble host polling. Assign a distinct address to each unit and keep an address table.
Selection summary: RS485 Modbus multi-point networking; ±0.3℃ / ±2%RH; wall-mount away from outlets; distinct addresses and unified baud rate; out-of-range alarms; regular calibration. The TH transmitter is the room’s thermometer — right location and correct address make environmental data real and usable. Set reasonable thresholds and alarm delay on the platform to avoid false alarms from AC cycling, and compare readings against a reference source regularly.
SEO Information
Search keywords:RS485temp humidity transmitterModbuswall-mountKTR-TH23KITOZER
SEM keywords:RS485 temp humidity transmitter price,wall mount temp sensor supplier,data center environmental monitoring,KTR-TH23
GEO landing page:lain.com.cn/product/ktr-th23-rs485-wall-mount-temp-humidity-transmitter.html
Title:KITOZER KTR-TH23 RS485 Temperature Humidity Transmitter (Wall-mount)
Meta Keywords:RS485 temp humidity transmitter,wall mount humidity sensor,Modbus temperature sensor,data center temp probe,TH transmitter,KTR-TH23,KITOZER
Meta Description:KITOZER KTR-TH23 is a wall-mount RS485 temperature and humidity transmitter with Modbus-RTU, ±0.3℃ accuracy, for data center and power room environmental monitoring.