KITOZER Rubber Insulating Mat 20kV 5mm Thick Switchroom Floor

Product Overview

KITOZER rubber insulating mat 20kV 5mm thick is laid on the floor in front of high-voltage switchgear, transformer chambers, and electrical control panels to provide auxiliary electrical protection against step and touch voltage. Manufactured from high-grade dielectric rubber compound with no fabric insert for the 20kV class, the mat maintains stable insulation from minus 10C to plus 55C and passes AC withstand test per IEC 61111. The smooth or corrugated surface prevents operator slipping, while the matte finish resists oil, grease, and UV. KITOZER supplies mats in standard rolls 1m wide by 10m long, cut to size with beveled edges to avoid trip hazards. The mat is an essential layer of personal protective equipment for any live switching operation.

Technical Specifications

Material: elastomer rubber, no conductive fillers. Thickness: 5mm for 20kV class. Width: 1m standard, 1.2m optional. Length: 10m roll. Color: red or black. AC withstand test: 20kV for 1 minute per IEC 61111. Dielectric breakdown: not less than 30kV. Volume resistivity: not less than 10^12 ohm.cm. Tensile strength: not less than 8 MPa. Elongation: not less than 300%. Operating temperature: minus 10C to plus 55C. Flame retardant: self-extinguishing. Surface: smooth or diamond corrugated. Certifications: IEC 61111, IS 15652, CE. Brand: KITOZER. Warranty: 3 years. Each roll carries a batch test certificate.

Application Scenarios

This mat is required by electrical safety codes in front of 10kV to 35kV switchgear panels, transformer low-voltage side, capacitor banks, motor control centers, and high-voltage test labs. It is laid along the operating aisle in substation control rooms, on the floor of generator sets, and around UPS battery racks. It also serves as the standing surface for linemen during live switching operations. In industrial plants, it protects operators at MCC buckets, VFD panels, and welding stations. In data centers, it provides insulation in front of PDUs and battery cabinets. The mat is cut to fit around floor anchors and cable openings. It is also used in electrical training labs and high-voltage test areas.

Advantages and Features

The 5mm thickness balances flexibility with dielectric strength; thinner mats can be damaged by dropped tools and sharps. The rubber compound is ozone-resistant, so it does not crack after years of indoor UV exposure. KITOZER mats are supplied with a test certificate per batch, listing AC withstand voltage and leakage current. The corrugated option provides slip resistance in oily environments. The matte surface does not glare under fluorescent lighting. Compared with PVC mats, this rubber compound maintains insulation at elevated temperatures and does not become brittle. The rolls are easy to transport and install, with seams taped using conductive-free jointing tape. The mat can be cleaned with mild detergent; no solvent.

Installation and Maintenance Recommendations

Lay the mat on a clean, dry, level concrete floor. Trim to size with a knife and bevel edges at 45 degrees to prevent tripping. Use non-conductive double-sided tape at corners to hold the mat flat. Ensure the mat extends at least 1m in front of the panel and 0.5m on each side. Inspect the mat visually every six months for cuts, punctures, or oily degradation. Perform a dielectric withstand test annually with a portable hipot tester, applying 1.5 times rated voltage for 1 minute. Replace the mat if any pinhole or crack appears, or if leakage current exceeds 10mA. Clean the surface with neutral detergent and water; never use gasoline or solvent. Store unused rolls flat in a cool, dark room away from ozone sources. KITOZER supplies test electrodes and annual test service.

Quality Assurance and Ordering Information

Every KITOZER mat roll is labeled with batch number, thickness, rated voltage, and test certificate covering AC withstand and leakage current. Rolls are packed in waterproof plastic and wooden crates. Standard lead time is 7 days. KITOZER also supplies 5kV, 10kV, 35kV, and 40kV insulating mats in 2mm, 3mm, and 6mm thicknesses. Custom sizes and colors are available. For export, KITOZER provides CE declaration and packing list. Samples can be shipped within 48 hours for engineering evaluation. KITOZER also supplies insulating gloves, boots, and hot sticks as a complete PPE package.

Technical Tips and Field Experience

From field experience, insulating mats degrade fastest at panel access points where operators stand repeatedly and where tools are dropped. KITOZER recommends rotating the mat every two years to spread wear, and keeping a spare mat on site for immediate replacement. In oily environments, the corrugated surface is preferred because smooth surfaces become slippery. Never use the mat as a work surface for drilling or hammering, as punctures void the dielectric rating. Record the annual hipot test results and compare leakage current; a rise above 10mA indicates hidden moisture penetration. KITOZER field engineers can provide on-site dielectric testing and mat replacement service.

Price

From $28 per square meter. Contact +86 13922289957 for roll pricing and cut-to-size service.