ToggleKITOZER KTR-SCAPC14 Fiber Adapter / SC Duplex APC OM4 Coupler
Brand: KITOZER Series: KTR-SCAPC14 Category: Data Center Engineering / Fiber Adapter
fiber adapterSC duplexAPCOM4ceramic sleeveKTR-SCAPC14
1. Overview
KITOZER KTR-SCAPC14 is an SC duplex APC fiber optic adapter mounted on patch panels, termination boxes and fiber distribution boxes. It mates two SC plugs precisely so cores align and light passes with low loss. OM4 multimode serves 10G/40G short-reach links in data centers, and the 8-degree APC polish minimizes back reflection for high-speed optics and video.
SC duplex means one adapter holds two SC ports side by side – one transmit, one receive – matching a two-fiber link. APC (angled physical contact) tilts the end face by 8 degrees so reflected light leaks into the cladding, giving return loss above 60 dB. It is more stable than UPC in long, high-rate links, but APC must never be mated to UPC – the faces will damage each other.
The core inside is a zirconia alignment sleeve; its precision sets insertion loss. KTR-SCAPC14 uses high-density zirconia sleeves for low, repeatable loss, a flame-retardant PC housing, dust caps and flange ears. Adapters are the highest-volume passive part in cabling – a 42U rack panel often takes dozens, configured in bulk as OM4 multimode, APC polish, SC duplex.
2. Key Features
SC duplex APC
- Two SC ports per duplex position.
- 8-degree angled APC end face.
- Return loss >=60 dB.
- OM4 multimode compatible.
Zirconia sleeve
- High-density zirconia sleeve.
- Low, stable insertion loss.
- Repeatable mating.
- Corrosion resistant, long life.
Flame-retardant housing
- Flame-retardant PC.
- Dust caps included.
- Flange or snap-in mount.
- Standard panel cutout.
Bulk supply
- Supplied by panel port count.
- Color-coded for OM4.
- Works with SC/UPC cords.
- Stackable panel mounting.
3. Specifications
| 项目 | KTR-SCAPC14(SC双工APC) | KTR-SCAPC14-P(面板型) | KTR-SCAPC14-D(适配器带盖) |
|---|---|---|---|
| 接口类型 | SC双工 | SC单工/双工 | SC双工 |
| 端面研磨 | APC 8度 | APC 8度 | APC 8度 |
| 光纤模式 | OM4多模 | OM4多模 | OM4多模 |
| 插入损耗(dB) | ≤0.3 | ≤0.3 | ≤0.3 |
| 回波损耗(dB) | ≥60 | ≥60 | ≥60 |
| 对准套筒 | 氧化锆陶瓷 | 氧化锆陶瓷 | 氧化锆陶瓷 |
| 插拔次数 | ≥1000 | ≥1000 | ≥1000 |
| 外壳材质 | PC阻燃 | PC阻燃 | PC阻燃+防尘盖 |
4. Reference Prices
KTR-SCAPC14 SC duplex APC OM4 adapter (zirconia sleeve, loss <=0.3 dB). Reference USD 4~11 / pc (ref. CNY 30~80 at ~7.2)
KTR-SCAPC14-P panel-mount APC adapter (flange, row mounting). Reference USD 6~17 / pc (ref. CNY 45~120 at ~7.2)
KTR-SCAPC14-D duplex APC adapter with dust cap (OM4, bulk). Reference USD 8~22 / pc (ref. CNY 60~160 at ~7.2)
Reference only; by simplex/duplex, cap/no-cap and quantity; bulk over 100 pcs negotiable; patch panels and cords excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- [‘OM4 10G/40G patch panel mating.’, ‘Termination box and distribution box ports.’, ‘High-density data center cabling.’, ‘Video and CATV APC links.’, ‘Cross-connect in fiber rooms.’]
6. Installation & Maintenance
Installation
- [‘Choose flange/snap-in to match panel cutout.’, ‘Push in from the front until it locks.’, ‘Grip the plug, never pull the fiber.’, ‘Keep APC on APC; never mate UPC.’, ‘Cap unused ports.’, ‘Spot-check loss with a power meter.’]
Maintenance
- [‘Clean the end face with alcohol before mating.’, ‘Cap idle ports after use.’, ‘If loss rises, clean the face and retest.’, ‘Reseat loose adapters.’, ‘Sample-test link loss for the log.’]
7. FAQ
- Q: Can APC and UPC mix?
A: No. APC is angled, UPC flat; mating them scratches the angled face, raising loss and contaminating it. Always APC to APC, UPC to UPC. - Q: Is the OM4 adapter interchangeable with OM3?
A: SC shapes are identical and OM4 is backward-compatible physically, but an OM4 link must be accepted at OM4 grade – keep the whole link OM4. - Q: How many links per duplex position?
A: A duplex position holds TX/RX SC ports for one two-fiber link. Count panel ports by two-fiber links. - Q: How is 0.3 dB loss measured?
A: Mate the adapter to standard cords and measure insertion loss by reference-jump method; log each port.
8. Trend & Selection
[‘As centers move to 200G/400G, OM4/OM5 and LC dominate, but SC APC stays widely used in video, surveillance and legacy panels. Choose APC for reflection-sensitive links, OM4 for the mode, simplex/duplex by link count; LC for density, SC APC for video and retrofit.’]
9. Delivery & Service
[‘KITOZER supplies SC duplex APC OM4 adapters in bulk, packed by panel port count. Delivery includes adapters, dust caps, mounting flanges and instructions. Bulk orders can be color-coded by mode and polish. Warranty covers mating damage; we advise on cleaning and loss testing.’]
10. Additional Notes
The common pitfall is mating APC to UPC. Crews plug an APC cord into a UPC panel for convenience, scarring the angled face on the first insertion and pushing loss from 0.3 dB above 1 dB, hard to trace. APC is blue – read the color and never mix.
Another trap is dirty end faces. A tiny speck looks like a boulder under the microscope and drives up error rates on high-speed links. Wipe one way with an alcohol swab before mating; never touch the face.
Selection summary: APC for reflection-sensitive links; keep the whole link OM4; simplex/duplex by link count; match panel cutout; cap idle ports; clean before mating. Tiny as they are, adapters are the first loss point – clean faces and correct grades keep 10G links stable.
SEO Information
Search keywords:fiber adapterSC duplexAPCOM4ceramic sleevecouplerKTR-SCAPC14KITOZER
SEM keywords:SC APC fiber adapter price,OM4 fiber coupler supplier,duplex fiber flange,KTR-SCAPC14
GEO landing page:lain.com.cn/product/ktr-scapc14-sc-duplex-apc-om4-fiber-adapter-coupler.html
Title:KITOZER KTR-SCAPC14 Fiber Adapter / SC Duplex APC OM4 Coupler
Meta Keywords:[‘fiber adapter,SC duplex,APC,OM4,ceramic sleeve,fiber coupler,KTR-SCAPC14,KITOZER’]
Meta Description:KITOZER KTR-SCAPC14 SC duplex APC OM4 fiber adapter with zirconia sleeve, insertion loss <=0.3 dB and return loss >=60 dB, for data center OM4 10G cabling.
Anchor: KITOZER official · Data center & low-voltage equipment
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com