ToggleKITOZER KTR-SCAPC3 Fiber Adapter / SC Duplex APC Singlemode
Brand: KITOZER Series: KTR-SCAPC3 Category: Data Center Engineering / Fiber adapter
SC duplex APCCeramic sleeveIL <0.2dBRL >60dBSM 9/125
1. Overview
In a fiber distribution frame, the adapter is the interface between pigtails and patch cords. APC end faces use an 8-degree angle polish to direct reflected light into the cladding for absorption rather than back along the source path, achieving return loss above 60 dB. This materially reduces reflection noise in PON, CATV and high-speed optical modules. The green housing is the international APC color code, distinct from blue UPC, preventing mis-mating.
The KITOZER KTR-SCAPC3 is an SC duplex APC singmode adapter with a zirconia ceramic sleeve. The smooth, precision-bored sleeve minimizes eccentricity when mated to SC/APC cords. Insertion loss <=0.2 dB, return loss >=60 dB, interchangeability <=0.2 dB, and >=1000 mating cycles. The duplex one-piece design fixes two SC ports in one panel cutout, doubling density versus simplex.
Selection confirms: end type (APC angle vs UPC sphere), mode (SM 9/125 vs MM 50/125), connector (SC/LC/FC/ST), sleeve material (ceramic preferred), and mounting (flange/panel). PON and 10G/25G+ links should standardize on APC to avoid eye-pattern degradation from reflection.
2. Key Features
End face and optics
- 8-degree APC angle polish.
- Return loss >=60 dB.
- Insertion loss <=0.2 dB.
- Zirconia ceramic sleeve.
Structure and ID
- SC duplex one-piece flange.
- Green housing identifies APC.
- Metal clip for firm retention.
- Standard panel cutout.
Reliability
- >=1000 mating cycles.
- Interchangeability <=0.2 dB.
- Operating temp -40 to +75 C.
- UL94-V0 flame-retardant housing.
3. Specifications
| Item | KTR-SCAPC3 SC Duplex APC Adapter |
|---|---|
| 适配器类型 | SC 双工 APC |
| 光纤模式 | 单模 9/125 μm |
| 端面 | APC 8°斜角 |
| 套管材质 | 陶瓷氧化锆 |
| 插入损耗 | ≤0.2 dB |
| 回波损耗 | ≥60 dB |
| 互换性 | ≤0.2 dB |
| 重复插拔 | ≥1000次 |
| 工作温度 | -40~+75℃ |
| 壳体颜色 | 绿色 (APC标识) |
4. Reference Prices
KTR-SCAPC3 SC duplex APC adapter (ceramic): USD 1.1~2.1 (ref. CNY 8~15 at ~7.2)
KTR-SCAPC3 SC duplex APC adapter (100 pcs): USD 97~167 (ref. CNY 700~1200 at ~7.2)
24-port adapter panel: USD 8~17 (ref. CNY 60~120 at ~7.2)
Reference only; final quote applies. Factory test report per batch. Bulk pricing available. Ceramic sleeve standard. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Adapter panels inside ODF frames.
- PON/FTTH optical distribution.
- Data center SAN fiber links.
- CATV transmitter/receiver ports.
- Broadcast and education private networks.
6. Installation & Maintenance
Installation
- Push adapter from the front until it clicks.
- Confirm clip engagement.
- Insert cord until the latch springs back.
- Label A/B direction.
- Verify with VFL and power meter.
- Never mate APC cords to UPC flanges.
Maintenance
- Clean end faces with lint-free swab and alcohol before mating.
- Keep dust caps on when unused.
- Re-test link loss quarterly.
- Replace a loose ceramic sleeve.
- Separate green APC from blue UPC stock.
7. FAQ
- Q: Can APC and UPC be mixed?
A: Not recommended. Mating an angle APC to a spherical UPC polishes damages the end face and raises loss. End types must be uniform in a link. - Q: Why green?
A: International convention uses green for APC (8-degree angle) and blue for UPC (sphere), so installers recognize and avoid mis-mating. - Q: Ceramic vs plastic sleeve?
A: Plastic has higher loss and wears quickly; loss rises after six months. Ceramic is precise and durable, and is mandatory in data centers. - Q: How many per panel?
A: A standard 1U 19-inch panel holds 24 SC duplex (48 fibers); high-density panels hold 48 duplex.
8. Trend & Selection
Fiber moves toward higher speed and density; APC end faces become mainstream in 10G/25G/100G links, and adapter volume grows with ODF density. Choose APC; ceramic sleeve; SM 9/125; green housing; panel mount. It is the “socket” of the optical link, and its small loss directly sets link margin.
9. Delivery & Service
KITOZER supplies KTR-SCAPC3 adapters with a factory test report (IL/RL sampled per batch), packed 100 per bag. Panels and cords are offered as matched kits.
10. Notes
A common pitfall is plugging an APC cord into a UPC adapter. The angled face scuffs the spherical flange and ruins the end face after a few insertions. Check panel color before work.
Another pitfall is mating unclean end faces. Dust creates scratches and creeping loss. Cleaning before every insertion is a habit.
Selection summary: SC duplex APC; ceramic sleeve; IL <=0.2 dB; RL >=60 dB; green housing; SM 9/125. It is the most basic yet critical passive part inside the ODF.
Systemically, one adapter costs 0.2 dB; two mated joints in a 48-fiber link eat 0.4 dB margin, which on long-haul 100G can decide between errors and clean operation.
Cost-wise, a single adapter costs about 10 CNY, but rework from a dirty end face can run to thousands in labor. Process discipline saves far more than part cost.
SEO Information
Search keywords: KITOZER
SEM keywords: fiber adapter, SC duplex APC, singmode coupler, green APC flange, KTR-SCAPC3, KITOZER
GEO landing page: lain.com.cn/product/432_fiber_adapter_sc8.html
Title: KITOZER KTR-SCAPC3 Fiber Adapter / SC Duplex APC Singlemode
Meta Keywords: fiber adapter, SC duplex APC, singmode coupler, green APC flange, KTR-SCAPC3, KITOZER
Meta Description: KITOZER KTR-SCAPC3 SC duplex APC singmode fiber adapter, ceramic sleeve, insertion loss <0.2dB, return loss >60dB, green housing.
Anchor: KITOZER · KITOZER Products
Contact Us
KITOZER Brand
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP:+86 19068534140
Web: lain.com.cn | gdlain.com