KITOZER
KITOZER

KITOZER SC duplex APC SM adapter

KITOZER KTR-SCAPC8 SC Duplex APC Singlemode Fiber Adapter

Brand: KITOZER Series: KTR-SCAPC8 Category: Cabling / Fiber Optics

SC duplexAPC polishSinglemode 9/125KTR-SCAPC8

KITOZER KTR-SCAPC8 SC Duplex APC Singlemode Fiber Adapter

1. Overview

KITOZER KTR-SCAPC8 is an SC duplex APC singlemode fiber adapter, also called a coupler or flange, used in fiber patch panels, terminal boxes and ODF units to join two SC connectors and pass the optical path straight through. The APC end-face uses an 8-degree angled polish, giving return loss above -60dB, widely used in CATV, broadcast, PON and datacenter backbone links where back-reflection is sensitive.

The adapter housing is engineering plastic with a ceramic sleeve; the duplex unit holds two SC ports for transmit and receive. For singlemode 9/125um, with ceramic ferrule and green APC end-face identification. Insertion loss no more than 0.2dB, return loss no less than 60dB, interchangeability and repeatability meeting industry standards. The flange clips into the square cutout of a 19-inch patch panel and also fits splice trays and fiber terminal boxes.

Widely used in datacenter telecom rooms, server racks, ODF frames, fiber terminal boxes and wall outlets. Typical deployment: backbone cable spliced to pigtails on one side of the adapter, equipment patch cords plugged in from the other side for cross-connect. APC end-faces must mate with APC cords, never with PC or UPC, otherwise the ferrule wears and back-reflection exceeds limits.

2. Key Features

SC duplex unit

  • Two-port one-piece design.
  • Fits SC connectors.
  • Keyed anti-mate orientation.
  • Flange clips into panel cutout.

APC angled end-face

  • 8-degree angled polish cuts reflection.
  • Return loss ≥60dB.
  • Green color coding.
  • For PON and CATV.

Ceramic sleeve

  • Zirconia ceramic sleeve.
  • Singlemode 9/125um.
  • Insertion loss ≤0.2dB.
  • Stable repeatability.

Compliant materials

  • Flame-retardant housing.
  • Wear-resistant ferrule.
  • Temp -40 to 75C.
  • Meets industry standards.

3. Specifications

Item KTR-SCAPC8 KTR-SCUPC8
Connector SC duplex SC duplex
Polish APC angled UPC spherical
Mode Singlemode 9/125 Singlemode 9/125
Insertion loss ≤0.2dB ≤0.2dB
Return loss ≥60dB ≥50dB
Color Green Blue
Application PON/CATV/backbone General data links
Op. temp -40 to 75C -40 to 75C

4. Reference Prices

KTR-SCAPC8 SC duplex APC adapter (ceramic sleeve): Reference USD 8 to 22 / pc (ref. CNY 60 to 160 at ~7.2)

KTR-SCUPC8 SC duplex UPC economy: Reference USD 4 to 13 / pc (ref. CNY 30 to 90 at ~7.2)

Reference only; price varies by quantity and packaging. OM3/OM4 multimode, LC/FC/ST other interfaces billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Datacenter ODF frames.
  • Fiber terminal boxes and splice trays.
  • PON optical split links.
  • CATV FTTH.
  • Server rack fiber cross-connect.

6. Installation & Maintenance

Installation

  • Clip adapter into panel cutout until it clicks.
  • Insert green APC cord into adapter.
  • Align the key; do not force or rotate.
  • Grip the pull tab when removing, never tug the cord.
  • Fit dust caps on unused ports.
  • Label ports with number and use.

Maintenance

  • Check for looseness quarterly.
  • Clean end-faces with a dedicated cleaning pen.
  • Dust-cap unused ports.
  • Replace worn or scratched ferrules.
  • Maintain a port and patch record.

7. FAQ

  • Q: Can APC and UPC mate?
    A: No. APC is 8-degree angled and UPC is spherical; the shapes differ, and mating them wears the ferrule and blows out return loss. Mate APC to APC and UPC to UPC. Colors: green APC, blue UPC.
  • Q: Are adapter and coupler the same?
    A: Yes, different names for the same part, also called flange. The function is mechanical alignment and optical continuity between two connectors.
  • Q: What does 0.2dB insertion loss mean?
    A: The light passing through the adapter loses no more than 0.2dB. In a link with several adapters losses add up; design usually reserves 0.3dB per adapter.
  • Q: Can multimode and singlemode adapters share?
    A: Same outer size but different sleeve inner diameter: multimode 50/125 or 62.5/125, singlemode 9/125. Mixing causes ferrule misalignment; buy them separately.

8. Trend & Selection

Fiber adapters are moving from SC/LC duplex toward high-density MPO/MTP for 40G/100G/400G datacenter links, but SC and LC remain the workhorses in building cabling, FTTH and PON. Choose APC green for PON and CATV; UPC blue for general data links; ceramic sleeve over metal; dust-cap unused ports; clean with a cleaning pen.

9. Delivery & Service

KITOZER supplies fiber-cabling packages: based on ODF capacity and link count, we recommend adapter specs and quantities. Bundled with patch cords, pigtails, splice trays and terminal boxes. Delivery includes adapters, dust caps and manual; bulk orders come in retail packs. Warranty covers replacement.

10. Additional Notes

The most common mistake is mixing APC and UPC. Green APC and blue UPC ferrules have different end-face shapes; forcing them in ruins the angled polish and reflection specs. Read the color first: green APC, blue UPC, beige multimode.

Another pitfall is leaving ports uncapped. Dusty datacenter air drops optical power sharply on a port left open for a month. Cap unused ports and clean with a pen, not an alcohol swab.

Selection summary: SC duplex APC green; ceramic sleeve; insertion loss no more than 0.2dB; return loss no less than 60dB; APC mates APC only; cap unused ports. A tiny adapter is the throat of the optical path; one dirty port can drop a whole link.

SEO Information

Search keywords:fiber adapterSC duplexAPC couplersinglemode flangefiber matingODF adapterKTR-SCAPC8KITOZER

SEM keywords:fiber adapter price,SC APC coupler supplier,singlemode flange,ODF adapter,PON fiber mating,KTR-SCAPC8,KITOZER

GEO landing page:lain.com.cn/product/ktr-scapc8-sc-duplex-apc-adapter.html

Title:KITOZER KTR-SCAPC8 SC Duplex APC Singlemode Fiber Adapter

Meta Keywords:fiber adapter,SC duplex,APC coupler,singlemode flange,fiber mating,ODF adapter,KTR-SCAPC8,KITOZER

Meta Description:KITOZER KTR-SCAPC8 SC duplex APC singlemode fiber adapter, ceramic sleeve, insertion loss no more than 0.2dB, return loss no less than 60dB, for ODF and patch panels.

Anchor: KITOZER · Datacenter engineering

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart