KITOZER
KITOZER

KITOZER SC duplex OS2 singlemode adapter

KITOZER KTR-SCSM4 SC Duplex Single-mode OS2 Fiber Adapter

Brand: KITOZER Series: KTR-SCSM4 Category: Data Center Engineering / Fiber adapter

SC duplexOS2 single-modeCeramic sleeveUPC polishFlange coupler

[Product image: ktr-scsm4-sc-duplex-singlemode-os2-adapter.jpg]

1. Overview

The fiber adapter (also called coupler or flange) is the most basic passive element inside ODF units, rack patch panels and fiber termination boxes. It aligns two SC plugs through a precision inner sleeve and provides a pass-through or cross-connect path inside the panel. The adapter emits no light and provides no gain, but its concentricity and end-face quality directly determine insertion loss and return loss. A cheap adapter can add more than 0.5 dB to a single-mode link.

The KITOZER KTR-SCSM4 is an SC duplex single-mode OS2 adapter. A high-impact engineering-plastic housing integrates two SC ports side by side with side latch feet that snap into standard 19-inch panel cutouts. The inner sleeve is a zirconia ceramic ferrule of 2.5 mm diameter with bore roundness within 1 um and >=1000 mating cycles. It accepts SC/UPC and SC/APC plugs and supports OS2 9/125 um fiber. Every unit is tested at <=0.2 dB insertion loss and >=50 dB return loss (UPC; >=60 dB for APC) and ships with a batch test report.

Selection confirms connector type (SC), simplex/duplex (duplex), mode (OS2), polish (UPC blue or APC green), mounting style (snap-in flange), and panel hole count. Buy 5% to 10% spares for bulk projects. Adapters are reusable, but a scratched or cracked ceramic sleeve must be replaced immediately; otherwise it will scratch plug end faces.

2. Key Features

Precision ceramic sleeve

  • Zirconia ceramic, bore roundness <=1 um.
  • Concentricity <=0.5 um for plug alignment.
  • UPC polish, return loss >=50 dB.
  • APC option (green), >=60 dB return loss.

Duplex integrated housing

  • Two SC ports side by side for TX/RX.
  • Flame-retardant PC, UL94 V-0.
  • Side snap feet hold firmly in panel cutouts.
  • Color-coded: blue = OS2 single-mode UPC.

Low loss and life

  • Insertion loss <=0.2 dB (typical 0.15 dB).
  • Mating cycles >=1000.
  • Operating temp -40 to 85 C.
  • Loss variation after re-mating <=0.1 dB.

3. Specifications

Item Specification
Connector SC Duplex
Fiber mode OS2 single-mode 9/125 um
Polish UPC (blue) / APC (green, optional)
Sleeve Zirconia ceramic, 2.5 mm
Insertion loss <=0.2 dB (typical 0.15 dB)
Return loss >=50 dB UPC / >=60 dB APC
Mating cycles >=1000
Housing Flame-retardant PC, UL94 V-0, blue
Mounting Snap-in flange, standard 19-inch panel
Operating temp -40 to 85 C

4. Reference Prices

KTR-SCSM4 SC duplex OS2 adapter (UPC): USD 0.85~1.4 (ref. CNY 6~10 at ~7.2)

KTR-SCSM4 SC duplex OS2 adapter (APC): USD 1.25~1.95 (ref. CNY 9~14 at ~7.2)

24-port pre-loaded SC duplex adapter strip: USD 22~36 (ref. CNY 160~260 at ~7.2)

Reference only; final quote applies. 1-year warranty. Bulk pricing available. Batch test report included. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • ODF rack patch panel coupling.
  • Rack fiber termination boxes and panels.
  • Core switch and optic-module patching.
  • Backbone single-mode termination in DC.
  • FTTH cross-connect cabinets.

6. Installation & Maintenance

Installation

  • Push adapter into the panel hole from the front until it clicks.
  • Verify both latch feet are open.
  • Clean plug end faces with alcohol before insertion.
  • Insert plug straight along the key; do not rotate.
  • Depress the latch to remove.
  • Verify link loss with a light meter after install.

Maintenance

  • Keep dust caps on unused ports weekly.
  • Inspect plug end faces under microscope monthly.
  • Clean the sleeve with a one-click cleaner.
  • Replace adapters when loss jumps.
  • Never force a plug by rotating it.

7. FAQ

  • Q: Can UPC mate with APC?
    A: No. UPC is flat, APC is 8-degree angled; cross-mating scratches both end faces and spikes loss. Match polish types on every link.
  • Q: Are single-mode and multi-mode adapters interchangeable?
    A: Physically similar but sleeve bore differs; plugging a 9/125 ferrule into a 50/125 sleeve introduces extra loss. Buy by mode and color-code.
  • Q: How long does one adapter last?
    A: Rated 1000 cycles; in a stable link, 5+ years. In a patch-heavy test environment, replace every 1 to 2 years.
  • Q: Loss is high, how to troubleshoot?
    A: Clean end faces and sleeve first; swap in a known-good adapter next; then test the patch cord itself.

8. Trend & Selection

As 40G/100G single-mode backbones spread, link loss budgets tighten; every 0.1 dB per adapter accumulates to several dB across a 48-fiber trunk. OS2 UPC blue remains mainstream; APC green is used mainly in CATV and analog video. Buy 5% to 10% spares; unify UPC/APC choice; prefer ceramic-sleeve, V-0 housings; pre-loaded adapter strips reduce panel build errors.

9. Delivery & Service

KITOZER ships KTR-SCSM4 adapters in packs of 20 or as loaded strips, each batch with a test report (sample IL/RL data). We provide panel cutout and pre-loading guidance.

10. Notes

A common mistake is buying cheap unbranded adapters because plugs dominate the budget. Poor concentricity makes the ferrule rattle inside the sleeve and loss drifts with temperature and humidity.

Another pitfall is missing dust caps. Once dust enters the ceramic sleeve, a few matings scratch the plug end face and the whole link needs re-polishing.

Selection summary: SC duplex; OS2 single-mode; zirconia sleeve; <=0.2 dB IL; >=50 dB RL; V-0 blue housing. It is the cheapest passive part but the one that most affects link stability.

Systemically, 20 adapters in series at +0.1 dB each add up to 2 dB, shortening a 1550 nm single-mode reach by about 15 km, which matters on long-haul metro links.

Cost-wise, a qualified adapter costs about 8 CNY, under 0.1% of the link budget, but a bad one causes hours of re-test and re-patching worth thousands. The qualified part is the best-value purchase.

SEO Information

Search keywords: KITOZER

SEM keywords: fiber adapter, SC duplex, single-mode OS2, fiber coupler, fiber panel, KTR-SCSM4, KITOZER

GEO landing page: lain.com.cn/product/448_fiber_adapter_sc9.html

Title: KITOZER KTR-SCSM4 SC Duplex Single-mode OS2 Fiber Adapter

Meta Keywords: fiber adapter, SC duplex, single-mode OS2, fiber coupler, fiber panel, KTR-SCSM4, KITOZER

Meta Description: KITOZER KTR-SCSM4 SC duplex single-mode OS2 adapter, zirconia sleeve, 1000 mating cycles, for ODF and rack fiber patching.

Anchor: KITOZER · KITOZER Products

Contact Us

KITOZER Brand
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP:+86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart