ToggleKITOZER KTR-SC48 48-Port SC Fully-Loaded Fiber Patch Panel
Brand: KITOZER Series: KTR-SC48 Category: Data Center Engineering / Fiber Cabling
48-port SCFully loaded1U rackSplice trayKTR-SC48

1. Overview
A fiber patch panel (ODF) is where outside-campus fiber cables converge and terminate in the room telecom closet. The carrier cable enters the building and lands on the ODF; its 24 or 48 fibers are each fusion-spliced to pigtails that plug into adapters, and patch cords on the front jump from adapters to switch optic ports. Panels come in 12, 24, 48, 72, 96-port counts; SC, LC, FC, ST interface types; and rack, wall-mount or drawer form factors. A 48-port SC is the most common: square SC snap-in connectors, ideal for aggregation-layer access. Fully loaded means adapters installed, splice trays included, pigtails included, ready to splice out of the box.
KITOZER KTR-SC48 is a 1U rack-mount 48-port SC fully-loaded panel. Standard 19-inch 1U, cold-rolled steel, black powder coat, front and rear doors; the front panel holds 48 SC simplex adapters; the rear carries two splice trays (24 fibers each). Each tray includes fusion-splice holders, fiber clamps, 304 stainless ties and 48 SC/UPC single-mode pigtails. Adapters use ceramic ferrules with insertion loss under 0.3 dB and return loss over 50 dB (UPC). A flip-down cable ring maintains a 40 mm minimum bend radius. KTR-SC48-SM: single-mode 9/125 um, blue adapters. KTR-SC48-MM: OM3 50/125 um, aqua. KTR-SC48-OM4: OM4, aqua.
Selection: confirm single-mode vs multi-mode (OM3/OM4 for in-building gigabit-to-desk; single-mode for long-haul backbones); confirm SC vs LC (SC is larger and cheaper, LC is denser); confirm fully-loaded vs empty shell; confirm 1U vs 2U. Do not mount the ODF directly above power trays, since a leaking power tray drips onto the ODF.
2. Key Features
Build
- 1U 19-inch rack
- Front/rear doors
- CRS steel powder coat
- Flip cable ring
Optics
- Ceramic ferrule
- Insertion loss <0.3 dB
- Return loss >50 dB
- SM/MM options
Contents
- 48 SC adapters
- 2 x 24-fiber splice trays
- 48 SC pigtails
- Ties and clamps
3. Specifications
| Item | KTR-SC48-SM | KTR-SC48-MM | KTR-SC48-OM4 |
|---|---|---|---|
| Ports | 48 | 48 | 48 |
| Fiber | 9/125 SM | 50/125 OM3 | 50/125 OM4 |
| Adapter color | Blue | Aqua | Aqua |
| Insertion loss | <0.3 dB | <0.3 dB | <0.3 dB |
| Return loss | >50 dB UPC | >50 dB UPC | >50 dB UPC |
| U-height | 1U | 1U | 1U |
| Reach | 10 km+ | 300 m 10G | 550 m 10G |
4. Reference Prices
KTR-SC48-SM single-mode loaded: Reference USD 62 to 90 / unit (ref. CNY 450-650 at ~7.2)
KTR-SC48-MM OM3 loaded: Reference USD 69 to 100 / unit (ref. CNY 500-720 at ~7.2)
KTR-SC48-OM4 loaded: Reference USD 83 to 118 / unit (ref. CNY 600-850 at ~7.2)
Empty shell: Reference USD 25 to 39 / unit (ref. CNY 180-280 at ~7.2)
Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Building telecom closet fiber aggregation
- Datacenter row-head ODF
- Carrier cross-connect termination
- Enterprise core room backbone
- Video/access-control fiber backhaul
6. Deployment & Installation
Mount
- M6 cage nuts in 19-inch rack
- Leave 1U for cable management
- Cable enters rear-bottom
- Ground strength member
Splice
- Fusion loss <0.05 dB/core
- Coil fibers clockwise in tray
- Bend radius >=40 mm
- Cleave sleeves in tray slots
Label
- Label every front port
- Both ends of each cord match
- Color-code backbone vs riser
- Use thermal label printer
7. FAQ
- Q: Which is denser, 48 SC or 48 LC?
A: LC is denser. An SC simplex connector takes one adapter position; 48 SC adapters carry 48 fibers. An LC duplex adapter holds two fibers in the same width, so LC panels carry double the fibers. KTR-SC48 targets the SC building market where the larger connector is forgiving and hard to mis-seat; for density choose LC. - Q: What does fully loaded include?
A: 48 SC adapters, two 24-fiber splice trays, 48 SC/UPC pigtails (single-mode), ties, clamps and manual. It does NOT include the incoming cable, patch cords or the rack. On site: dress the cable in, fusion-splice each fiber to a pigtail, plug pigtails into adapters, and patch from the front to switches. - Q: Can I mix single-mode and multi-mode adapters?
A: Mechanically yes, they share the same panel, but never patch an SM port to an MM port with one cord. Core sizes differ (9 um vs 50 um) and insertion loss jumps massively. In practice, backbone rows use blue SM adapters, access rows use aqua MM adapters, on separate rows. - Q: ODF vs OTB terminal box?
A: The ODF mounts in a 19-inch rack at 24-96 ports and handles splicing, patching and management for main distribution. The OTB is a small wall- or rack-mount box at 12-24 ports for termination only, in work areas or small rooms. 48-port SC belongs to the ODF family.
8. Trend & Selection
As 40G and 100G access spreads, the smaller LC connector is replacing SC in new datacenters, where 1U panels now carry 96 or 144 fibers. But SC remains dominant in building telecom closets and retrofits because the larger connector is forgiving and hard to mis-seat. KTR-SC48 targets retrofit and building closets where a 48-port 1U panel is cost-effective. The future is pre-terminated MPO trunks with fan-out modules to cut on-site splicing, plus smart ODFs with electronic labels and port-sense sensors visible to the NMS. Select by: fiber type, port count, fully-loaded pigtails, splice-tray count, bend-radius protection.
9. Delivery & Service
KITOZER supplies KTR-SC48 by model. Each ships with unit, mounting accessories and manual. 1-year warranty; batch projects can bundle peripheral gear and on-site commissioning.
10. Additional Notes
Confirm port specs, power rating and communication protocol against field equipment before ordering; keep clear of strong EMI and heat sources; verify wiring and labels before energizing. For batch orders, request samples first to confirm compatibility with existing systems.
Common mistake: comparing price but ignoring parameters. Models in the same series look similar, but ports, load and accuracy differ — wrong models cause on-site rework. Send the full part number (including suffix such as -SM/-MM/-S) to sales to confirm.
Second pitfall: not planning service space. Leave at least 600 mm rear cable/service space and 800 mm front operating space, or future swaps and cable work become painful.
Third blunder: shipping factory alarm thresholds. Default thresholds rarely match site conditions — tune them after commissioning based on real readings to avoid both false and missed alarms.
Selection summary: match site conditions first, pick model, reserve service space, calibrate thresholds on-site, and pilot one unit before bulk.
SEO Information
Search keywords:KTR-SC48KITOZER
SEM keywords:fiber patch panel,48 port fiber patch panel,SC patch panel,ODF unit,KTR-SC48,KITOZER
GEO landing page:lain.com.cn/product/ktr-sc48-fiber-patch-panel.html
Title:KITOZER KTR-SC48 48-Port SC Fully-Loaded Fiber Patch Panel
Meta Keywords:fiber patch panel,48 port fiber patch panel,SC patch panel,ODF unit,KTR-SC48,KITOZER
Meta Description:KITOZER KTR-SC48 1U 48-port SC fully-loaded fiber patch panel with adapters, splice trays and pigtails, single/multi-mode, rack-mount.