KITOZER
KITOZER

KITOZER SCB13 630kVA F Class Dry Type Transformer With IP20 Enclosure

Product Overview

The KITOZER SCB13-630/10 dry type transformer targets mid sized commercial and industrial distribution where efficiency, fire safety, and compact footprint matter. The 630 kVA unit converts 10 kV primary to 0.4 kV secondary and is the common rating for shopping mall main risers, hospital critical feeders, mid size data center upstream transformers, and plant substations. Vacuum cast epoxy insulation, Class F temperature class, and an IP20 sheet steel enclosure form the standard package. The SCB13 series improves no load loss by around 15 percent versus the SCB10 generation, cutting continuous standby energy cost in facilities that run at low average loading but never shut down.

The core uses stepped lap mitred silicon steel with a four to five step joint geometry, which reduces magnetostriction and no load loss simultaneously. The LV winding is foil wound for even current distribution and good short circuit strength, while the HV winding is multilayer round wire cast in epoxy. Thermal sensors are embedded in the hottest spot of each winding, not just on the surface, giving accurate overheat protection. The enclosure is fabricated from cold rolled steel with epoxy powder coating, RAL7035 as standard, and can be painted to match site aesthetics.

Technical Specifications

Rated capacity 630 kVA, HV 10 kV with plus or minus 2 times 2.5 percent no load tap, LV 0.4 kV, Dyn11, impedance 6.0 percent. No load loss 0.81 kW, load loss at 120 degrees 6.55 kW, no load current 0.9 percent. Winding insulation class F, temperature rise 100 K, max ambient 40 degrees C, altitude 1000 m. Cooling AN as standard, AF optional with ceiling mounted fans raising output to 1.2 times rated. Partial discharge below 10 pC. Enclosure IP20 as standard, IP23 optional. Temperature controller PT100 on HV and LV windings with LED display, alarm at 130 degrees, trip at 150 degrees, fan start at 110 degrees. Optional copper winding, aluminum winding, or copper clad aluminum. Terminal box with cable gland plates, earthing busbar, and lifting eyes. Complies with IEC 60076, GB/T 1094.11, CE.

The temperature controller provides Modbus RTU communication as an option, allowing the BMS or SCADA system to read winding temperatures, fan status, and alarm history. Two dry contact outputs are provided for remote alarm and trip. The enclosure has front door for LV busbar access, rear removable panels for core inspection, and a separate terminal box for HV cable entry. Anti vibration mounting pads are fitted under the feet to reduce structure borne noise. The unit weighs approximately 1900 kg, so the plinth must be structurally rated for dynamic load during short circuit.

Application Scenarios

A 630 kVA dry unit typically serves one entire shopping mall floor, a hospital wing including HVAC and IT load, a mid sized data center upstream transformer before UPS, a pharmaceutical clean room distribution room, or a commercial printing workshop. Because the unit is dry and Class E fire rated, it is placed in basement transformer rooms, indoor substations adjacent to load, and containerized power modules. The IP20 enclosure prevents accidental finger contact and falling objects, suitable for indoor clean rooms. For dusty factories, the IP23 variant with inlet louvers and filtered air is preferred. The Dyn11 connection and 6 percent impedance give good fault limiting and harmonic current suppression for VFD and LED lighting loads.

In shopping malls, the 630 kVA transformer powers escalators, lighting, air handling units, and retail tenant feeders on one floor. In hospitals, it may feed a critical care wing with life safety, lighting, and receptacle circuits, separate from the main incoming. In mid size data centers, it is the upstream transformer for a 300 kVA UPS system supporting several server racks. In pharmaceutical clean rooms, the dry design avoids oil contamination risk. The unit is also used in school campus distribution, hotel power, and supermarket back of house feeders.

Advantages

Low no load loss reduces idle energy waste in 24 hour facilities. The stepped lap core uses grain oriented silicon steel with mitred joints, cutting magnetostriction noise to below 60 dB. Epoxy resin winding is crack resistant under repeated thermal cycling and shows zero oil maintenance. Modular enclosure allows side cable entry or top busbar entry to match civil design. Temperature controller provides trending alarm and remote contacts for building management systems. Parallel operation with identical units is supported for redundancy and future expansion. The unit ships complete with tap changer accessible from front, earthing terminals, and factory routine test certificate.

Installation and Maintenance

Install on a level concrete plinth with vibration dampers, maintain 1.0 m front access and 0.8 m side clearance. Connect HV by shielded cable to front bushings and LV by busbar or cable lugs to the secondary terminals. Verify tap position: if site voltage is high, choose minus 2.5 percent; if low, choose plus 2.5 percent. After installation, perform a one hour no load energization observation, then apply load gradually. Preventive maintenance includes annual insulation resistance, dust removal with dry compressed air, busbar torque check, and thermal sensor calibration. Inspect enclosure gaskets every two years. If the temperature controller alarms, first check room ventilation, filter condition, and whether fans are running. Do not spray water or solvent on the winding surface.

Price

From $12,800 per piece with aluminum winding, IP20 enclosure, and standard temperature controller. Copper winding upgrade, IP23 enclosure, and AF fan kit available on request.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com