KITOZER
KITOZER

KITOZER SF6 Breaker: 35kV 1250A Circuit Breaker For Substation

KITOZER 35kV 1250A SF6 circuit breaker is a medium-voltage outdoor or indoor switching device used in 35kV substations, industrial incoming lines, and wind or solar collector substations. Sulfur hexafluoride gas provides excellent dielectric and arc-quenching properties, enabling high fault interruption capability within a compact tank. This model is rated 1250A continuous current and 25kA short-circuit breaking, suitable for 35kV cable and overhead line protection where compact footprint and low maintenance are priorities.

Product Overview

The breaker is a three-pole common-tank or pole-mounted design depending on the selected variant, with interrupters sealed inside stainless steel or aluminum enclosures pressurized with SF6 gas. A spring or magnetic actuator operates all three poles synchronously through an insulating drive shaft. Density monitors continuously track gas pressure and temperature, giving alarm and lockout signals before pressure drops below the safe operating threshold. The tank is fitted with a pressure relief diaphragm to vent internal faults safely. Bushings are available in porcelain or composite silicone rubber for pollution-prone coastal or industrial sites.

Technical Specifications

Rated voltage 40.5kV, rated frequency 50/60Hz, rated normal current 1250A, rated short-circuit breaking current 25kA, rated short-time withstand 25kA for 4s, rated peak withstand 63kA, rated operating sequence O-0.3s-CO-180s-CO, power frequency withstand 95kV for 1 minute, lightning impulse withstand 185kV peak. SF6 gas pressure at 20 degrees Celsius typically 0.45MPa absolute, gas leakage rate below 0.5 percent per year. Operating mechanism spring stored energy, motor supply DC 110V/220V or AC 220V, shunt trip coils, anti-pumping relay. Mechanical endurance 10,000 operations, IP67 for pole tank, ambient temperature minus 40 to plus 40 degrees Celsius. Compliant with IEC 62271-100 and GB 1984.

Applications

Typical uses include 35kV incoming and outgoing bays in industrial distribution substations, wind farm and solar PV collector substation breakers, industrial plant main 35kV switchgear, railway traction feeder breakers, and mining substation protection. The breaker is also deployed as the tie breaker between two 35kV bus sections in metropolitan and rural substations. Outdoor pole mount variants fit overhead line re-closer duties, while indoor withdrawable variants fit KYN61 switchgear rooms.

Advantages

SF6 dielectric strength allows compact pole dimensions and reduces substation land area compared with air breakers. Sealed tanks mean no external arc products and long maintenance intervals. Density monitoring prevents operation under low gas pressure, which is the main failure cause of gas breakers. Spring operation provides independent manual and electrical tripping. The breaker can be used in high pollution, high altitude, and coastal corrosive environments when composite bushings are selected. Low acoustic noise and no flame exhaust suit urban and residential substation locations.

Installation and Maintenance

After receiving the breaker, check gas pressure gauge and density relay readings before installation. Mount on the supporting structure with the specified torque, connect primary bushings without inducing mechanical stress, and route secondary cables through the gland plates. Commissioning includes gas leak check using an ultrasonic or sniffing detector, contact resistance measurement, insulation test, protection relay injection, and mechanical operation counts. Maintenance every four years includes gas moisture measurement, density relay calibration, mechanism lubrication, and visual inspection of bushings. SF6 gas must be recovered using approved handling equipment during servicing, and never vented to atmosphere. Keep gas refill kits and spare density relays on site for remote substations.

Price

From $4,980/pc. Contact +86 13922289957 for SF6 breaker quotation.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com