The KITOZER 35kV SF6 circuit breaker is a high-voltage switching device engineered for the protection and control of 35kV substation feeders, main transformers, and industrial incoming lines. Sulfur hexafluoride gas acts as an excellent arc-quenching and insulating medium, allowing the breaker to interrupt high short-circuit currents with low overvoltage and stable dielectric recovery. The breaker is built as a dead-tank or live-tank structure depending on configuration, with a spring or magnetic actuator operating mechanism and integrated gas density monitoring. It suits outdoor substations, industrial cogeneration plants, mining site distribution, and 35kV collection networks for large solar and wind farms where high fault levels and long service intervals are expected.
Table of Contents
ToggleTechnical Specifications
Rated voltage 40.5kV, rated frequency 50Hz, rated normal current 1250A, rated short-circuit breaking current 25kA, short-time withstand current 25kA for 4 seconds, peak withstand current 63kA, rated operating sequence O-0.3s-CO-180s-CO. SF6 gas at rated pressure 0.45MPa at 20 degrees Celsius, with density relay for low-pressure alarm and lockout. Operating mechanism: stored-energy spring, motor charge at DC 110V or 220V. Power frequency withstand voltage 95kV, lightning impulse withstand voltage 185kV. Outdoor installation, seismic resistance per IEC 62271-100, pollution level class suitable for industrial and coastal environments with optional silicone housings.
Applications
The KITOZER 35kV SF6 circuit breaker is typically installed in 35kV switchgear rooms, outdoor kiosk substations, and gas-insulated switchgear line-ups. It protects the incoming and outgoing feeders of main 35/10kV transformers in large industrial parks, petrochemical plants, and steel mills. In renewable energy projects it acts as the point-of-connection breaker between the 35kV collector bus and the step-up transformer bank feeding the transmission grid. It is also used in municipal 35kV distribution substations, traction power supply for railways, and large water pumping and irrigation districts.
Because SF6 breakers tolerate high fault levels and outdoor weather, they are favored for exposed locations where vacuum breakers would be impractical. The breaker can be fitted with current transformer bushings, surge arrester interfaces, and motor-operated disconnector interlocks to form a complete 35kV switching bay. Its compatibility with digital protection relays and bay controllers makes it suitable for unmanned or remotely operated substations.
Key Advantages
SF6 gas provides outstanding dielectric strength and arc extinction, so the breaker interrupts fault currents cleanly with low restrike risk and low switching overvoltages. The sealed tank design prevents internal pollution and reduces maintenance to periodic gas-level checks. The gas density relay alarms before pressure drops to unsafe levels and locks out operation if the leak continues, preventing attempts to switch with insufficient insulation. KITOZER units are factory-filled, factory-tested, and shipped ready for installation with calibrated density sensors.
The spring mechanism offers high mechanical reliability, typically rated for 10,000 or more mechanical operations. The breaker supports close and trip via protection relay, local pushbutton, and remote SCADA commands. Optional pole discrepancy monitoring, anti-pumping, and trip-circuit supervision enhance safety. Common bushing and accessory interfaces mean the breaker fits existing 35kV switchroom layouts without major civil modifications.
Installation and Maintenance
Position the breaker on a level concrete or steel foundation with adequate clearance for the lifting mechanism and live parts. Check that SF6 pressure reads in the green zone before closing any pole. Verify torque on primary busbar connections and confirm earthing of the tank and mechanism cabinet. Commission the protection relay to trip the breaker on overcurrent, earth fault, and gas low-pressure alarms, and verify all interlocks with associated disconnectors and earth switches.
Maintenance consists of routine gas density checks every six months, visual inspection of bushings for cracks or tracking, and cleaning of insulator surfaces. Every few years, measure contact resistance and operate the mechanism to confirm timing. If gas is below the alarm threshold, locate the leak with a suitable detector and recharge only by certified personnel using filtered, dried SF6. Follow environmental regulations for gas recovery, because SF6 is a greenhouse gas and must be recovered rather than vented. Lubricate the mechanism linkages and replace the desiccant cartridge at the recommended intervals.