Table of Contents
ToggleProduct Overview
The KITOZER SF6 inflatable ring main unit (RMU) is a compact gas insulated switchgear for 12 kV secondary distribution networks in residential areas, commercial centers, box substations, and industrial plants. All live parts are sealed in a stainless steel gas tank filled with SF6, giving full environmental protection and zero outdoor bushing maintenance. The RMU combines load break switch, fuse switch combination, and vacuum circuit breaker in a compact footprint. It is the standard choice for ring network supply and transformer protection.
The gas tank is laser welded stainless steel, sealed for life, and filled with SF6 at low pressure. Switch contacts are sealed inside the tank and operated by external shafts with rotary seals. The outer cabinet is sheet steel with epoxy powder coating, IP3X protection. Cable connections use inner cone plugs, fully insulated and touch proof. The RMU can be configured with several functional units: load break switches for loop feed, fuse switch combination for transformer protection, and vacuum circuit breaker for cable network protection. This modularity allows each RMU to match the site topology.
Technical Specifications
Rated voltage 12 kV, rated current 630 A, frequency 50 Hz. Short time withstand 20 kA for 1 second, peak 50 kA. Load break switch 630 A, breaking capacity 20 kA with fuses. SF6 gas sealed tank, gas density monitor. Mechanical life 10000 operations. Enclosure IP67 gas tank, IP3X outer cabinet. Cable type inner cone. Complies with IEC 62271-200, GB/T 3906.
The load break switch uses SF6 as both dielectric and arc quenching medium, with a rotary contact mechanism. The fuse switch combination uses current limiting fuses that clear primary faults in less than 1 cycle, and a mechanical striker that trips the load break switch on fuse operation. The vacuum circuit breaker option uses a sealed vacuum interrupter for cable network protection, with spring mechanism. A gas density monitor provides alarm if pressure drops. Earthing switch is fitted on cable side. The RMU is supplied with operating handle, cable connectors, and mounting brackets.
Application Scenarios
Inflatable RMUs are used in ring network supply for residential communities, commercial plazas, box substations, and industrial plant secondary distribution. Sealed gas tank suits outdoor and polluted environments. The compact size fits in limited space. Fuse switch combination protects distribution transformers up to 1250 kVA. Vacuum circuit breaker feeders serve cable networks requiring protection.
In residential communities, RMUs form a ring network feeding several box substations. In commercial plazas, they are the incoming switchgear for pad mounted transformers. In box substations, they are the HV compartment. In industrial plants, they form the secondary distribution ring. For underground cable networks, the fully insulated inner cone connectors eliminate bushing flashover risk. The sealed tank is suitable for coastal, industrial, and polluted atmospheres where open air switchgear would require frequent cleaning.
Advantages
Sealed SF6 tank eliminates insulator cleaning. Compact footprint. IP67 protection. Long mechanical life. Safe operation with interlocks. Low maintenance. Suitable for outdoor and indoor installation. Five year warranty.
Installation and Maintenance
Install on a plinth or in a box substation. Connect inner cone cables. Check gas density before energizing. Commissioning includes switch operation, fuse fit, and interlock check. Maintenance every five years: gas density check, mechanism lubrication. No routine insulator cleaning. Keep cabinet ventilation.
Price
From $7,200 per unit including 2 load break switches and 1 fuse switch combination. Vacuum breaker feeder and extension modules are optional.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com