KITOZER
KITOZER

KITOZER Shielded Anechoic Chamber Solution

Table of Contents

1. System Overview

KITOZER shielded anechoic chamber (also known as electromagnetic shielding anechoic chamber, microwave anechoic chamber) is a special electromagnetic protection and testing facility built based on the Faraday cage principle and electromagnetic wave absorbing technology. Its core functions are to block the interaction of internal and external electromagnetic waves and suppress internal electromagnetic wave reflection, so as to create a pure electromagnetic space featuring “zero intrusion of external interference, zero leakage of internal signals and zero superposition of spatial reflection”.

The system integrates precision shielding structures, full-frequency absorbing materials, electromagnetic filter components and intelligent supporting systems, complying with domestic and international standards including GB/T 12190, EN50147-1 and GJB5792. Its shielding effectiveness covers the full frequency band from 10kHz to 18GHz, and the quiet zone performance meets the requirements of precision testing. Widely applied in military aerospace, electronic communication, medical equipment, automotive industry and classified information protection, it serves as core infrastructure for EMC (Electromagnetic Compatibility) testing, antenna R&D, classified information confidentiality and precision electronic inspection.

Internal view of shielded anechoic chamber

2. System Composition

KITOZER shielded anechoic chamber adopts a four-core-module structure: shielding main body, wave absorbing system, filter components and intelligent supporting facilities. All modules coordinate to realize electromagnetic shielding and anechoic performance, with detailed components as follows:

2.1 Shielding Enclosure

  • Material: High-quality cold-rolled steel plate (SPCC) with thickness of 1.5mm–3mm, hot-dip galvanized for anti-corrosion, galvanized layer thickness ≥20μm.
  • Structure: Welded type (high shielding effectiveness) and assembled type (detachable and relocatable). Standard module size: 3m×1m. Modules are connected via conductive shielding gaskets and high-strength bolts to guarantee electrical continuity.
  • Function: Form a fully enclosed Faraday cage to isolate electromagnetic signals, acting as the core carrier of shielding effectiveness.

3D model of shielding anechoic chamber

2.2 Wave Absorbing Material System

  • Ferrite absorbing tiles: Laid on the bottom layer of walls and ceilings to absorb low-frequency electromagnetic waves from 30MHz to 1GHz. Adopting magnetic loss design, flame retardant, moisture-proof and high temperature resistant.
  • Conical/wedge wave absorbers: Mounted above ferrite tiles, made of polyurethane foam impregnated with carbon glue to absorb medium and high-frequency electromagnetic waves from 1GHz to 18GHz. Featuring gradual wave impedance structure with reflection loss ≥25dB.
  • Floor wave absorbing materials: Movable absorbing wedges are laid on the floor of fully anechoic chambers; semi-anechoic chambers adopt highly conductive grounding flat plates without wave absorbing materials.

2.3 Shielded Door System

  • Types: Single-knife / double-knife / triple-knife shielded doors (performance improves sequentially). Opening modes: manual (small anechoic chambers), electric (high-frequency use) and pneumatic (heavy-duty doors).
  • Structure: Copper-plated finger spring strips on door frame + plug-in locking of door leaf, triple dynamic sealing. Door thickness ≥80mm, shell made of 1mm galvanized plate and door frame of 3mm cold-rolled steel, coated with military-grade paint.
  • Function: Maintain the integrity of the shielding body while allowing personnel and equipment access to prevent electromagnetic leakage.

2.4 Electromagnetic Filter Components

  • Power filters: Special for EUT (Equipment Under Test), lighting and system. Covering 10kHz–10GHz, insertion loss ≥100dB, leakage current <1A, line-to-ground withstand voltage 1500VDC.
  • Ventilation waveguide windows: Honeycomb / cut-off waveguide type installed at air vents, enabling air circulation while blocking electromagnetic waves. Shielding effectiveness ≥80dB, flame retardant, dust-proof and moisture-proof.
  • Signal filters / feed-through panels: N-type, BNC, SMA connectors, standard 300mm×300mm panels for penetration of RF signals, optical fibers and control lines to maintain shielding continuity.

2.5 Intelligent Supporting System

Factory production workshop

  • Electrical lighting: 300W explosion-proof halogen lamps, 220V/380V shielded sockets, emergency lighting (battery life ≥180 minutes).
  • Environmental monitoring: Temperature & humidity sensors, smoke detectors, video surveillance, voice intercom and access control system.
  • Testing aids: Antenna towers, electric turntables (load capacity 500kg–5t), quiet zone positioning system and RF cable assemblies.
  • Grounding system: Independent grounding electrodes with grounding resistance ≤1Ω and equipotential bonding to avoid interference from ground potential difference.

3. System Classification

KITOZER shielded anechoic chambers are classified by four dimensions: testing function, shielding grade, size specification and structural form, matching diverse scenario demands.

3.1 Classification by Testing Function

  • Fully Anechoic Chamber (FAR): Wave absorbing materials laid on six surfaces to simulate free space with minimal reflection. Applicable to antenna testing, radiated emission/immunity testing and sensitivity experiments. Shielding effectiveness: 80dB–140dB.
  • Semi-Anechoic Chamber (SAR): Conductive grounding flat plate on floor without wave absorbers, wave absorbers laid on the other five surfaces to simulate open test sites. Mainstream commercial type for EMC certification and automotive electronic testing.
  • Simple Shielded Chamber: Only shielding enclosure and basic filters without internal wave absorbers, for conduction testing, electrostatic testing and classified information protection. Low cost and fast construction.

3.2 Classification by Shielding Grade

  • Basic Grade (Class C): Shielding effectiveness ≥60dB @10kHz–1GHz, ≥80dB @1GHz–10GHz. Meet demands of civil EMC testing and general laboratories.
  • Military Grade (Class B): Shielding effectiveness ≥80dB @10kHz–1GHz, ≥100dB @1GHz–18GHz, complying with GJB5792-2006 Grade D standard. For military, aerospace and classified sites.
  • Ultra-High Shielding Grade (Class A): Full-band shielding effectiveness ≥120dB @10kHz–18GHz with double-layer shielding structure. For high-precision metrology, satellite R&D, quantum communication and cutting-edge fields.

On-site installation construction

3.3 Classification by Size Specification

  • 3m Chamber: Internal dimension 9m×6m×6m, quiet zone diameter 2m, for small equipment ≤2m (mobile phones, routers).
  • 5m Chamber: Internal dimension 11m×7m×9m, quiet zone diameter 3m, for medium-sized equipment (laptops, medical devices).
  • 10m Chamber: Internal dimension 21m×12m×9m, quiet zone diameter 5m–8m, for large equipment (automobiles, server clusters).
  • Custom Mini Chamber: Internal dimension ≤6m×5m×4m, for field probe calibration, component testing and small classified computer rooms.

3.4 Classification by Structural Form

  • Welded Chamber: Integrally welded steel plates with zero gaps, highest shielding effectiveness, suitable for fixed venues and long-term use.
  • Assembled Chamber: Standard modules bolted together, detachable, relocatable and expandable, for rented venues, temporary projects and multi-site reuse.
  • Embedded Chamber: Integrated with building structures, shielding enclosure embedded in walls/floors, space-saving and high stability, for new laboratories and military buildings.

4. System Schematic Diagram

Configuration diagram of shielded anechoic chamber

5. Full System Configuration List (3 Tiers: Basic / Medium / Premium, Brand: KITOZER)

5.1 Basic Configuration List (Class C Basic Grade, 3m Simple Fully Anechoic Chamber)

表格

No.Product NameModel & SpecTechnical ParametersQtyUnitBrandRemarks
1Shielding EnclosureKITOZER-SH-3M-CInternal size 9m×6m×6m; 1.5mm cold-rolled steel plate; assembled type; hot-dip galvanized anti-corrosion; shielding effectiveness ≥60dB@10kHz–1GHz, ≥80dB@1GHz–10GHz; grounding resistance ≤1Ω1SetKITOZERIncluding standard modules, connecting bolts and conductive gaskets
2Ferrite Absorbing TileKITOZER-FE-3010Size 100mm×100mm×20mm; frequency 30MHz–1GHz; reflection loss ≥15dB; flame retardant UL94-V0; moisture-proof, temperature resistance -20℃~+80℃1200PieceKITOZERLaid on walls and ceiling bottom layer
3Conical Wave AbsorberKITOZER-CON-118Height 300mm; frequency 1GHz–18GHz; reflection loss ≥20dB; polyurethane carbon-impregnated foam; UL94-V0 flame retardant; moisture-proof, density 30kg/m³850PieceKITOZERLaid above ferrite tiles
4Manual Single-Knife Shielded DoorKITOZER-SD-M11Door opening 2000mm×1150mm; manual operation; single copper-plated finger spring strip; door thickness 80mm; 1mm galvanized plate + 3mm cold-rolled steel frame; shielding effectiveness ≥60dB1UnitKITOZERPersonnel access
5EUT Power FilterKITOZER-PF-16A-C16A/220V; 10kHz–10GHz; insertion loss ≥60dB; leakage current <3mA; line-ground withstand voltage 1500VDC, two-wire1UnitKITOZERPower supply for tested equipment
6Lighting Power FilterKITOZER-PF-10A-C10A/220V; 10kHz–10GHz; insertion loss ≥60dB; leakage current <3mA, two-wire1UnitKITOZERPower supply for lighting system
7Ventilation Waveguide WindowKITOZER-WG-600CSize 600mm×600mm; honeycomb structure; shielding effectiveness ≥60dB; air volume ≥500m³/h; flame retardant & dust-proof2PieceKITOZERVentilation and heat dissipation
8Signal Feed-Through PanelKITOZER-FB-3030C300mm×300mm; 2×N, 4×BNC connectors; DC–10GHz; insertion loss ≥60dB, 50Ω impedance1PieceKITOZERRF signal penetration
9Electrical Lighting SystemKITOZER-EL-C6×300W explosion-proof halogen lamps; 8×220V shielded sockets; emergency lighting (180min backup); shielded cables1SetKITOZERLighting and auxiliary power supply
10Grounding SystemKITOZER-GD-CIndependent grounding electrodes; 50mm² copper cables; equipotential busbar; grounding resistance ≤1Ω1SetKITOZERSafety grounding & anti-interference

5.2 Medium Configuration List (Class B Military Grade, 5m Standard Semi-Anechoic Chamber)

表格

No.Product NameModel & SpecTechnical ParametersQtyUnitBrandRemarks
1Shielding EnclosureKITOZER-SH-5M-BInternal size 11m×7m×9m; 2mm cold-rolled steel plate; composite welded & assembled; hot-dip galvanized + anti-rust paint; shielding effectiveness ≥80dB@10kHz–1GHz, ≥100dB@1GHz–18GHz; grounding resistance ≤0.5Ω1SetKITOZERIncluding main frame, sealed welding and anti-corrosion treatment
2Ferrite Absorbing TileKITOZER-FE-2010100mm×100mm×25mm; 20MHz–1.5GHz; reflection loss ≥20dB; UL94-V0 flame retardant; moisture-proof, -30℃~+100℃ high permeability1800PieceKITOZERWall & ceiling bottom laying
3Wedge Wave AbsorberKITOZER-WED-418Height 400mm; 800MHz–18GHz; reflection loss ≥25dB; carbon-impregnated polyurethane; UL94-V0; density 35kg/m³, 30° wedge angle1200PieceKITOZERAbove ferrite tiles
4Electric Double-Knife Shielded DoorKITOZER-SD-E12Door opening 2100mm×1200mm; electric remote + manual dual mode; double copper finger strips; door thickness 100mm; 1.5mm galvanized plate + 5mm steel frame; shielding effectiveness ≥80dB, anti-collision seal1UnitKITOZERPersonnel & small equipment access
5EUT High-Current Power FilterKITOZER-PF-32A-B32A/380V; 10kHz–18GHz; insertion loss ≥80dB; leakage current <1A; 2000VDC withstand voltage, three-wire redundant design2UnitKITOZERPower supply for high-power tested equipment
6System Power FilterKITOZER-PF-20A-B20A/220V; 10kHz–18GHz; insertion loss ≥80dB; leakage current <0.5A, two-wire, -25℃~+85℃ wide temperature2UnitKITOZERLighting, monitoring and turntable power supply
7Ventilation Waveguide WindowKITOZER-WG-800B800mm×800mm thickened honeycomb; shielding effectiveness ≥80dB; air volume ≥800m³/h; flame retardant, dust/moisture/corrosion resistant3PieceKITOZERForced ventilation cooling
8Signal Feed-Through PanelKITOZER-FB-3030B300mm×300mm; 4×N,6×BNC,2×SMA; DC–18GHz; insertion loss ≥80dB, compatible with 50Ω/75Ω, waterproof connectors2PieceKITOZERRF & control line penetration
9Electric TurntableKITOZER-TR-500BLoad capacity 500kg; diameter 2m; adjustable speed 0–10rpm; positioning accuracy ±0.1°; shielded motor, conductive slip ring, matched for semi-anechoic chamber1UnitKITOZER360° rotation of DUT (Device Under Test)
10Antenna TowerKITOZER-AT-5BHeight 5m, electric lifting (0.5–5m adjustable); load 50kg; positioning accuracy ±1mm; shielded structure for test antennas1SetKITOZERHeight adjustment for test antenna installation
11Environmental Monitoring SystemKITOZER-MON-BTemp & humidity sensor (-20℃~+60℃, 0–100%RH); smoke detector; 2 HD cameras; voice intercom; card access control, remote data transmission1SetKITOZEREnvironmental monitoring & safety protection
12Electrical Lighting SystemKITOZER-EL-B8×300W explosion-proof halogen lamps; 12×220V/380V shielded sockets; 240min emergency backup; shielded flame-retardant cables, leakage protection1SetKITOZERLighting & high-power power supply
13Grounding SystemKITOZER-GD-BCopper grounding electrodes; 70mm² copper cables; equipotential copper busbar; grounding resistance ≤0.5Ω, anti-corrosion treatment1SetKITOZERGrounding, anti-interference & lightning protection

5.3 Premium Configuration List (Class A Ultra-High Shielding Grade, 10m Fully Anechoic Chamber)

表格

No.Product NameModel & SpecTechnical ParametersQtyUnitBrandRemarks
1Double-Layer Shielding EnclosureKITOZER-SH-10M-AInternal size 21m×12m×9m; inner 2mm + outer 3mm cold-rolled steel, full welding; hot-dip galvanized + military anti-corrosion; full-band shielding ≥120dB@10kHz–18GHz; grounding resistance ≤0.1Ω, double-layer insulation isolation1SetKITOZERDouble-layer frame, sealed welding, insulation & anti-corrosion
2High-Performance Ferrite TileKITOZER-FE-1515150mm×150mm×30mm; 15MHz–2GHz; reflection loss ≥25dB; UL94-V0; moisture-proof, -40℃~+120℃ ultra-high permeability, low loss3500PieceKITOZERBottom laying for walls, ceiling and floor
3Composite Conical Wave AbsorberKITOZER-CON-618Height 600mm; 500MHz–18GHz; reflection loss ≥30dB; carbon-impregnated polyurethane composite layer; UL94-V0; density 40kg/m³ gradual taper2800PieceKITOZERFull six-surface laying above ferrite
4Pneumatic Triple-Knife Shielded DoorKITOZER-SD-P15Door opening 2400mm×1500mm; pneumatic auto-sensing + manual backup; triple copper finger strips; door thickness 120mm; 2mm galvanized plate + 8mm steel frame; shielding effectiveness ≥100dB, explosion-proof seal & auto locking1UnitKITOZERLarge equipment access, military-grade sealing
5High-Current Power FilterKITOZER-PF-63A-A63A/380V; 10kHz–18GHz; insertion loss ≥100dB; leakage current <0.5A; 3000VDC withstand voltage, three-phase four-wire redundant dual circuit, -40℃~+100℃ wide temp3UnitKITOZERPower supply for ultra-high-power DUT
6Precision Power FilterKITOZER-PF-30A-A30A/220V; 10kHz–18GHz; insertion loss ≥100dB; leakage current <0.1A, two-wire, low noise, military-grade precision3UnitKITOZERPower supply for monitoring, antenna tower and precision instruments
7High-Density Ventilation Waveguide WindowKITOZER-WG-1000A1000mm×1000mm double honeycomb; shielding effectiveness ≥100dB; air volume ≥1200m³/h; flame retardant, dust/moisture/corrosion resistant, military standard4PieceKITOZERForced cooling with high-frequency shielding
8Multi-Channel Signal Feed-Through PanelKITOZER-FB-4040A400mm×400mm; 6×N,8×BNC,4×SMA,2×fiber optic; DC–18GHz; insertion loss ≥100dB, compatible with 50Ω/75Ω/single-mode fiber, vacuum seal3PieceKITOZERRF, fiber and control line penetration
9Heavy-Duty Electric TurntableKITOZER-TR-5T-ALoad capacity 5t; diameter 3m; adjustable speed 0–5rpm; positioning accuracy ±0.05°; shielded motor, high-precision slip ring, anti-slip load surface for fully anechoic chambers1UnitKITOZERPlace large DUT such as vehicles
10High-Precision Antenna TowerKITOZER-AT-10AHeight 10m, electric lifting (1–10m adjustable); load 100kg; positioning accuracy ±0.5mm; shielded structure, auto calibration for high-precision test antennas1SetKITOZERPrecise positioning of high-end test antennas
11Quiet Zone Positioning SystemKITOZER-QZ-AQuiet zone diameter 5m; positioning accuracy ±1mm; 3D coordinate calibration, auto quiet zone search, real-time data display matched for 10m fully anechoic chamber1SetKITOZERPrecise positioning of test quiet zone to guarantee accuracy
12Intelligent Environmental Monitoring SystemKITOZER-MON-ATemp & humidity (-40℃~+80℃,0–100%RH); smoke/gas alarm; 4 HD IR cameras; two-way voice intercom; fingerprint + card access control, remote control & data storage, abnormal alarm1SetKITOZERFull-range monitoring, safety protection & remote management
13Electrical Lighting SystemKITOZER-EL-A12×500W explosion-proof halogen lamps; 20×220V/380V/660V shielded sockets; 360min emergency backup; shielded flame-retardant fire-resistant cables, intelligent power distribution, leakage/overvoltage/overcurrent protection1SetKITOZERLighting & ultra-high-power intelligent power supply
14Lightning & Anti-Static Grounding SystemKITOZER-GD-ACopper-clad steel grounding electrodes; 95mm² copper cables; pure copper equipotential busbar; grounding resistance ≤0.1Ω, lightning arrester, anti-corrosion & anti-static, military standard1SetKITOZERGrounding, anti-interference, lightning & static protection
15RF Cable AssemblyKITOZER-RF-A50m low-loss RF cable (DC–18GHz); N/BNC connectors, shielded & waterproof joints, high temperature resistance, low signal loss1SetKITOZERSignal transmission between antennas and test equipment

6. Full Product Technical Specifications

6.1 Shielding Enclosure Technical Parameters

On-site shielding chamber installation

  • Material: SPCC cold-rolled steel plate, thickness 1.5mm (Basic) / 2mm (Medium) / 2mm inner + 3mm outer double-layer (Premium).
  • Anti-corrosion: Hot-dip galvanized (Basic) / galvanized + anti-rust paint (Medium) / galvanized + military anti-corrosion coating (Premium), galvanized layer ≥20μm.
  • Shielding Effectiveness:
    • Class C Basic: ≥60dB @10kHz–1MHz, ≥70dB @1MHz–1GHz, ≥80dB @1GHz–10GHz
    • Class B Medium: ≥80dB @10kHz–1MHz, ≥90dB @1MHz–1GHz, ≥100dB @1GHz–18GHz
    • Class A Premium: ≥120dB full band 10kHz–18GHz
  • Grounding Resistance: ≤1Ω (Basic) / ≤0.5Ω (Medium) / ≤0.1Ω (Premium)
  • Structure: Assembled (Basic) / composite welded & assembled (Medium) / full welded double-layer (Premium)

6.2 Wave Absorbing Material Technical Parameters

6.2.1 Ferrite Absorbing Tile

  • Size: 100mm×100mm×20mm (Basic) / 100mm×100mm×25mm (Medium) / 150mm×150mm×30mm (Premium)
  • Operating Frequency: 30MHz–1GHz (Basic) / 20MHz–1.5GHz (Medium) / 15MHz–2GHz (Premium)
  • Reflection Loss: ≥15dB (Basic) / ≥20dB (Medium) / ≥25dB (Premium)
  • Flame Retardancy: UL94-V0 for all series
  • Temperature Resistance: -20℃~+80℃ (Basic) / -30℃~+100℃ (Medium) / -40℃~+120℃ (Premium)
  • Density: 4.5g/cm³ all series

6.2.2 Conical/Wedge Wave Absorber

  • Height: 300mm (Basic) / 400mm (Medium) / 600mm (Premium)
  • Operating Frequency: 1GHz–18GHz (Basic) / 800MHz–18GHz (Medium) / 500MHz–18GHz (Premium)
  • Reflection Loss: ≥20dB (Basic) / ≥25dB (Medium) / ≥30dB (Premium)
  • Material: Carbon-impregnated polyurethane foam all series
  • Flame Retardancy: UL94-V0 all series
  • Density: 30kg/m³ (Basic) / 35kg/m³ (Medium) / 40kg/m³ (Premium)
  • Temperature Resistance: same as ferrite tiles

6.3 Shielded Door Technical Parameters

Interior of finished shielding chamber

  • Door Opening Size: 2000mm×1150mm (Basic) / 2100mm×1200mm (Medium) / 2400mm×1500mm (Premium)
  • Opening Mode: Manual (Basic) / Electric (Medium) / Pneumatic (Premium)
  • Finger Strip Type: Single-knife (Basic) / Double-knife (Medium) / Triple-knife (Premium), copper-plated material
  • Door Thickness: 80mm (Basic) / 100mm (Medium) / 120mm (Premium)
  • Shielding Effectiveness: ≥60dB (Basic) / ≥80dB (Medium) / ≥100dB (Premium)
  • Sealing: Single ring (Basic) / Double ring (Medium) / triple dynamic seal (Premium)

6.4 Power Filter Technical Parameters

  • Rated Current: 10A/16A (Basic) / 20A/32A (Medium) / 30A/63A (Premium)
  • Rated Voltage: 220V (Basic) / 220V/380V (Medium) / 220V/380V/660V (Premium)
  • Operating Frequency: 10kHz–10GHz (Basic) / 10kHz–18GHz (Medium & Premium)
  • Insertion Loss: ≥60dB (Basic) / ≥80dB (Medium) / ≥100dB (Premium)
  • Leakage Current: <3mA (Basic) / <1A (Medium) / <0.5A (Premium)
  • Line-Ground Withstand Voltage: 1500VDC (Basic) / 2000VDC (Medium) / 3000VDC (Premium)
  • Temperature Resistance: -20℃~+85℃ (Basic) / -25℃~+85℃ (Medium) / -40℃~+100℃ (Premium)

6.5 Ventilation Waveguide Window Technical Parameters

EMC test layout inside chamber

  • Size: 600mm×600mm (Basic) / 800mm×800mm (Medium) / 1000mm×1000mm (Premium)
  • Shielding Effectiveness: ≥60dB (Basic) / ≥80dB (Medium) / ≥100dB (Premium)
  • Air Volume: ≥500m³/h (Basic) / ≥800m³/h (Medium) / ≥1200m³/h (Premium)
  • Structure: Standard honeycomb (Basic) / thickened honeycomb (Medium) / double honeycomb (Premium)
  • Flame Retardancy: UL94-V0 all series
  • Temperature Resistance: -20℃~+80℃ (Basic) / -30℃~+100℃ (Medium & Premium)

6.6 Electric Turntable Technical Parameters

  • Load Capacity: 500kg (Medium) / 5t (Premium)
  • Diameter: 2m (Medium) / 3m (Premium)
  • Rotation Speed: adjustable 0–10rpm (Medium) / 0–5rpm (Premium)
  • Positioning Accuracy: ±0.1° (Medium) / ±0.05° (Premium)
  • Drive: Shielded motor for both grades
  • Slip Ring: Standard (Medium) / high-precision (Premium)

6.7 Antenna Tower Technical Parameters

  • Height: 5m (Medium) / 10m (Premium), electrically adjustable lifting
  • Load Capacity: 50kg (Medium) / 100kg (Premium)
  • Positioning Accuracy: ±1mm (Medium) / ±0.5mm (Premium)
  • Material: Aluminum alloy (Medium) / high-strength aluminum alloy with shielded structure (Premium)

Full anechoic chamber interior with absorbers

6.8 Quiet Zone Core Performance Parameters

  • Quiet Zone Diameter: 2m (3m chamber) / 3m (5m chamber) / 5m (10m chamber)
  • Normalized Site Attenuation (NSA): 30MHz–1GHz, deviation ≤±3.5dB (standard limit ±4.0dB)
  • Field Uniformity (FU): 26MHz–18GHz, 0dB~+6dB, compliant with IEC61000-4-3
  • Transmission Loss (TL): 1GHz–18GHz, deviation ≤±3.5dB
  • Cross Polarization: ±25dB
  • Multipath Loss: ±0.25dB

7. Full Product Application Scope

7.1 Military & Aerospace Industry

  • EMC testing of military electronic equipment, radar R&D, satellite component testing, missile control system inspection
  • Classified computer rooms, command centers and intelligence processing hubs to prevent electromagnetic signal leakage and external interference
  • Antenna testing for aviation & aerospace equipment, precision inspection of spacecraft parts, anti-interference testing of avionics

7.2 Electronic Communication Industry

Test bench inside shielding chamber

  • R&D and testing of 5G/6G base station antennas, EMC certification testing for consumer electronics such as mobile phones and routers
  • Radiated emission/immunity testing and sensitivity calibration of RF modules, microwave devices and communication equipment
  • Chip-level EMC testing, precision inspection of semiconductor components, R&D testing of high-frequency circuits

7.3 Medical Device Industry

  • Electromagnetic shielding for MRI equipment, anti-interference testing of medical imaging devices, precision inspection of medical instruments
  • EMC testing and calibration of cardiac pacemakers, medical sensors, high-frequency electrosurgical units
  • Classified IT systems and data centers in hospitals to avoid electromagnetic interference and information leakage

7.4 Automotive Industry

  • Full-vehicle EMC testing, radiation testing of vehicle electronics (navigation, radar, autonomous driving systems)
  • EMC testing of new energy vehicle BMS and motor controllers
  • Anti-interference and radiated emission testing of auto parts (wiring harnesses, sensors, ECUs)

7.5 Classified Information & Security Industry

  • Classified computer rooms, confidential meeting rooms and data centers of government agencies, military institutions and financial institutions
  • Prevent electromagnetic wiretapping and information leakage to guarantee secure storage & transmission of classified data
  • Electromagnetic shielding and anti-interference testing of security monitoring and classified communication equipment

7.6 Scientific Research, Education & Metrology Industry

  • EMC laboratories, RF laboratories and antenna R&D labs in universities and research institutes
  • Calibration labs for metrology institutes, field probe calibration, microwave component metrology, precision instrument calibration
  • Teaching experimental platforms for electronic information, communication engineering and EMC majors

7.7 Other Industrial Fields

  • EMC testing of industrial automation equipment, PLC control systems and inverters
  • Radiation & anti-interference testing of photovoltaic inverters and energy storage equipment
  • EMC certification testing and anti-interference inspection of smart home and IoT devices

8. Full Product Advantages

Test equipment layout inside chamber

8.1 Core Functional Advantages

  • Ultra-High Shielding Effectiveness: Full series covers 10kHz–18GHz, ≥60dB (Basic), ≥80dB (Medium), ≥120dB (Premium) complying with military standards, fully blocking internal & external electromagnetic wave exchange
  • Excellent Anechoic Performance: Wave absorbers adopt gradual impedance design with reflection loss from ≥20dB to ≥30dB, NSA/FU/TL quiet zone performance meets international standards to simulate pure free space
  • Full-Band Coverage: Shielding and absorbing components cover low-frequency magnetic field, medium-frequency electric field and high-frequency microwave, compatible with all electromagnetic testing scenarios
  • High Stability: Premium steel, military anti-corrosion, precision welding/assembly, stable shielding performance with service life ≥20 years

8.2 Customization Advantages

  • Size Customization: Custom 3m/5m/10m chambers and non-standard dimensions up to over 20m per customer site and testing requirements
  • Performance Customization: Custom shielding grades (C/B/A), quiet zone sizes and absorber configurations for civil, industrial, military and classified scenarios
  • Structural Customization: Welded, assembled and embedded structures for fixed venues, rented sites and new buildings respectively
  • Function Customization: Integrated intelligent monitoring, remote control, auto-test, anti-static and lightning protection to build all-in-one solutions

8.3 Production & Processing Advantages

Full absorber lining inside chamber

  • In-House Factory Manufacturing: KITOZER owns a 10,000㎡ modern production workshop equipped with German laser cutters, CNC benders and auto welding robots, full self-production for controllable quality with no intermediate dealers
  • OEM/ODM Service: Custom brand logo, appearance and packaging, mass production support with short delivery cycles
  • Precision Machining: Laser cutting + CNC bending with tolerance ±0.5mm; argon arc seamless welding eliminates missing/cold welds to ensure shielding electrical continuity
  • Strict Quality Inspection: Every unit undergoes shielding effectiveness, quiet zone performance and electrical safety testing before delivery with third-party certification reports

8.4 Confidentiality & Safety Advantages

3D structural drawing of shielding chamber

  • Military-Grade Confidential Design: Fully sealed shielding enclosure, triple-seal shielded doors and full-band filter components to prevent electromagnetic leakage for classified protection
  • Anti-Eavesdropping: Blocks electromagnetic radiation signals to avoid interception of internal confidential information by external wiretapping devices
  • Safety Configuration: Explosion-proof, flame-retardant and leakage protection electrical systems; lightning & anti-static grounding; smoke/temp-humidity alarm environmental monitoring to protect personnel and equipment

8.5 Stock & Delivery Advantages

  • Standard Stock Availability: Stocked 3m Basic, 5m Medium chambers and common spare parts (shielded doors, filters, absorbers) with 7–15 day fast shipment
  • Fast Custom Delivery: 3–5 day design cycle, 15–30 day production cycle, 7–15 day installation & commissioning, shorter overall lead time than industry average
  • Nationwide On-Site Installation: Professional installation teams covering all provinces in China, providing one-stop survey, design, installation, commissioning and training

8.6 Technical Parameter Advantages Over Peers

  • Shielding Enclosure: Thicker standard steel, superior anti-corrosion, shielding effectiveness 5–10dB higher than competitors, lower grounding resistance and stronger long-term stability
  • Wave Absorbers: High-permeability ferrite + composite carbon wedges deliver 30% improved low-frequency absorption, higher high-frequency reflection loss, wider temperature range and superior flame/moisture resistance
  • Shielded Doors: Triple copper finger strips + triple sealing offer 20dB higher shielding than ordinary doors, auto lock, anti-collision seal and low maintenance
  • Power Filters: Military filter chips with high insertion loss, minimal leakage current and stable performance under wide temperature and harsh working conditions
  • Test Auxiliary Equipment: Turntable positioning ±0.05°, antenna tower ±0.5mm, quiet zone positioning ±1mm, exceeding industry standards to guarantee accurate test data

Exterior view of triple-knife shielded door

9. Tender Control Parameters for All Products (* Core Control Items)

9.1 Shielding Enclosure Control Parameters

    • Shield Material: SPCC cold-rolled steel plate ≥1.5mm (Basic) / ≥2mm (Medium) / inner ≥2mm + outer ≥3mm double-layer (Premium)
    • Shielding Effectiveness: ≥60dB@10kHz–1MHz (Basic) / ≥80dB (Medium) / ≥120dB (Premium); ≥70dB@1MHz–1GHz (Basic) / ≥90dB (Medium) / ≥120dB (Premium); ≥80dB@1GHz–18GHz (Basic) / ≥100dB (Medium) / ≥120dB (Premium)
    • Anti-Corrosion Treatment: Hot-dip galvanized (Basic) / galvanized + anti-rust paint (Medium) / galvanized + military anti-corrosion coating (Premium), galvanized layer ≥20μm
    • Grounding Resistance: ≤1Ω (Basic) / ≤0.5Ω (Medium) / ≤0.1Ω (Premium)
  1. Structure Type: Assembled (Basic) / composite welded & assembled (Medium) / full welded double-layer (Premium)

9.2 Wave Absorber Control Parameters

9.2.1 Ferrite Tile

    • Operating Frequency: 30MHz–1GHz (Basic) / 20MHz–1.5GHz (Medium) / 15MHz–2GHz (Premium)
    • Reflection Loss: ≥15dB (Basic) / ≥20dB (Medium) / ≥25dB (Premium)
    • Flame Retardancy: UL94-V0
  1. Size: 100mm×100mm×20mm (Basic) / 100mm×100mm×25mm (Medium) / 150mm×150mm×30mm (Premium)
  2. Temperature Resistance: -20℃~+80℃ (Basic) / -30℃~+100℃ (Medium) / -40℃~+120℃ (Premium)

9.2.2 Conical/Wedge Absorber

Whole chamber rendering with blue absorbers

    • Operating Frequency: 1GHz–18GHz (Basic) / 800MHz–18GHz (Medium) / 500MHz–18GHz (Premium)
    • Reflection Loss: ≥20dB (Basic) / ≥25dB (Medium) / ≥30dB (Premium)
    • Flame Retardancy: UL94-V0
  1. Height: 300mm (Basic) / 400mm (Medium) / 600mm (Premium)
  2. Material: Carbon-impregnated polyurethane foam

9.3 Shielded Door Control Parameters

    • Door Opening Size: ≥2000mm×1150mm (Basic) / ≥2100mm×1200mm (Medium) / ≥2400mm×1500mm (Premium)
    • Shielding Effectiveness: ≥60dB (Basic) / ≥80dB (Medium) / ≥100dB (Premium)
    • Finger Strip Type: Single-knife (Basic) / Double-knife (Medium) / Triple-knife (Premium), copper-plated
  1. Opening Mode: Manual (Basic) / Electric (Medium) / Pneumatic (Premium)
  2. Door Thickness: ≥80mm (Basic) / ≥100mm (Medium) / ≥120mm (Premium)

9.4 Power Filter Control Parameters

    • Operating Frequency: 10kHz–10GHz (Basic) / 10kHz–18GHz (Medium & Premium)
    • Insertion Loss: ≥60dB (Basic) / ≥80dB (Medium) / ≥100dB (Premium)
    • Rated Current: ≥16A (Basic) / ≥32A (Medium) / ≥63A (Premium)
    • Line-Ground Withstand Voltage: ≥1500VDC (Basic) / ≥2000VDC (Medium) / ≥3000VDC (Premium)
  1. Leakage Current: <3mA (Basic) / <1A (Medium) / <0.5A (Premium)

9.5 Ventilation Waveguide Window Control Parameters

    • Shielding Effectiveness: ≥60dB (Basic) / ≥80dB (Medium) / ≥100dB (Premium)
    • Air Volume: ≥500m³/h (Basic) / ≥800m³/h (Medium) / ≥1200m³/h (Premium)
    • Flame Retardancy: UL94-V0
  1. Size: ≥600mm×600mm (Basic) / ≥800mm×800mm (Medium) / ≥1000mm×1000mm (Premium)

9.6 Anechoic Chamber Quiet Zone Control Parameters

    • Quiet Zone Diameter: ≥2m (3m chamber) / ≥3m (5m chamber) / ≥5m (10m chamber)
    • Normalized Site Attenuation (NSA): 30MHz–1GHz, deviation ≤±3.5dB
    • Field Uniformity (FU): 26MHz–18GHz, 0dB~+6dB
    • Transmission Loss (TL): 1GHz–18GHz, deviation ≤±3.5dB

9.7 Electric Turntable Control Parameters

    • Load Capacity: ≥500kg (Medium) / ≥5t (Premium)
    • Positioning Accuracy: ±0.1° (Medium) / ±0.05° (Premium)
  1. Diameter: ≥2m (Medium) / ≥3m (Premium)

9.8 Antenna Tower Control Parameters

    • Height: ≥5m (Medium) / ≥10m (Premium), electrically adjustable lifting
    • Positioning Accuracy: ±1mm (Medium) / ±0.5mm (Premium)

10. Complete Product Solution Packages

10.1 Military, Aerospace & Classified Shielded Anechoic Chamber Solution

  • Pain Points Demanded: Ultra-high shielding ≥100dB, anti-electromagnetic leakage, military confidentiality, full-band coverage, wide environmental adaptability
  • Configuration: Class A premium double-layer shielding enclosure (≥120dB@10kHz–18GHz) + composite wave absorbers (reflection loss ≥30dB) + pneumatic triple-knife shielded door (≥100dB) + military power filters (insertion loss ≥100dB) + lightning & anti-static grounding (ground resistance ≤0.1Ω) + military intelligent environmental monitoring system
  • Core Advantages: Full-band ultra-high shielding, military confidentiality design, anti-wiretapping, wide temperature & humidity resistance, long-term stable performance for classified protection and precision testing
  • Applicable Scenarios: Military command centers, classified computer rooms, radar R&D labs, satellite component testing hubs

10.2 EMC Testing Anechoic Chamber Solution for Electronic Communication

  • Pain Points Demanded: Standard quiet zone performance, full-band wave absorption, accurate test data, compatibility with various communication equipment, fast delivery
  • Tiered Configurations:
    • Small devices (mobile phones, routers): Class C Basic 3m fully anechoic chamber (2m quiet zone, NSA deviation ≤±3.5dB) + standard absorbers + manual single-knife door + basic filters
    • Medium devices (base stations, RF modules): Class B Medium 5m semi-anechoic chamber (3m quiet zone, field uniformity 0~+6dB) + wedge absorbers + electric double-knife door + precision filters + electric turntable & antenna tower
    • Large devices (communication cabinets, base station arrays): Class A Premium 10m fully anechoic chamber (5m quiet zone, TL deviation ≤±3.5dB) + composite absorbers + pneumatic triple-knife door + high-current filters + 5t heavy turntable, 10m high-precision antenna tower & quiet zone positioning system
  • Core Advantages: Compliant quiet zone indicators, precise test data, full-frequency coverage, fully customizable, fast delivery
  • Applicable Scenarios: 5G/6G antenna testing, consumer electronics EMC certification, RF component R&D, chip-level EMC testing

10.3 Electromagnetic Shielding Solution for Medical Equipment

  • Pain Points Demanded: Shielding ≥80dB, anti-electromagnetic interference, zero radiation leakage, eco-friendly and medical-safe materials
  • Configuration: Class B Medium shielding enclosure (≥100dB@10kHz–18GHz) + ferrite & wedge absorbers + electric double-knife door + medical low-leakage power filters + anti-static grounding + sterile eco coating
  • Core Advantages: High shielding efficiency, anti-interference, non-toxic odorless sterile surface, anti-static design for medical testing and shielding projects
  • Applicable Scenarios: MRI shielding, medical imaging labs, precision medical instrument testing, hospital classified data centers

10.4 Automotive Industry EMC Testing Anechoic Chamber Solution

  • Pain Points Demanded: Oversized quiet zone, high-load turntable, full-band shielding, compatible with full vehicle & component testing, anti-vibration stability
  • Configuration: Class A Premium 10m semi-anechoic chamber (21m×12m×9m internal, 5m quiet zone) + five-surface composite absorbers (conductive floor plate) + 2400×1500mm pneumatic triple-knife door + high-current power filters + 5t heavy turntable, 10m high-precision antenna tower & vehicle access ramp
  • Core Advantages: Oversized quiet zone, heavy load capacity, full-band shielding, vibration-resistant stable structure, accurate full vehicle/component test results
  • Applicable Scenarios: Full vehicle EMC testing, vehicle radar/autonomous driving system testing, new energy vehicle BMS & motor controller testing

10.5 Classified Computer Room Shielding Solution for Government & Finance

  • Pain Points Demanded: Shielding ≥80dB, anti-electromagnetic wiretapping, compact layout, easy installation & low maintenance
  • Configuration: Class B Medium assembled shielding enclosure (≥100dB@10kHz–18GHz) + manual/electric double-knife door + power/signal filters + equipotential grounding + anti-static flooring + basic lighting & monitoring
  • Core Advantages: High shielding efficiency, anti-leakage wiretapping, detachable relocatable assembly, compact footprint, simple maintenance, cost-effective
  • Applicable Scenarios: Government classified computer rooms, financial institution data center confidential zones, confidential meeting rooms, anti-wiretapping offices

10.6 Laboratory Solution for Universities & Research Institutes

  • Pain Points Demanded: Standard performance, budget-friendly, dual-purpose for teaching & research, easy operation & expandable layout
  • Configuration: Class C Basic 3m fully anechoic chamber (teaching experiments) / Class B Medium 5m semi-anechoic chamber (research testing) + standard absorbers + electric double-knife door + precision filters + electric turntable & antenna tower + teaching demonstration system
  • Core Advantages: Standard compliance, cost control, dual teaching/research function, simple operation, expandable upgrade matching university lab demands
  • Applicable Scenarios: University EMC labs, RF labs, antenna R&D labs, precision testing labs for research institutions

11. Full Product Application Cases

11.1 Military & Aerospace Cases

  1. Radar R&D Lab of a Military Research Institute: Adopted KITOZER Class A Premium 10m fully anechoic chamber with double-layer shielding, full-band shielding ≥120dB@10kHz–18GHz and composite absorbers, 5m quiet zone. Used for military radar antenna R&D, radiated emission/immunity testing and sensitivity calibration, delivering accurate test data complying with military standards.
  2. Satellite Component Testing Center of an Aerospace Technology Group: Deployed KITOZER Class B Medium 5m fully anechoic chamber with welded shielding enclosure, shielding effectiveness ≥100dB@10kHz–18GHz and wedge absorbers, 3m quiet zone. Applied to precision testing & calibration of satellite communication components and microwave devices, isolating external electromagnetic interference to guarantee test precision.

11.2 Electronic Communication Cases

  1. EMC Laboratory of a 5G Communication Equipment Manufacturer: KITOZER Class B Medium 5m semi-anechoic chamber (11m×7m×9m internal, 3m quiet zone, field uniformity 0~+6dB) for EMC certification testing of 5G base stations, RF modules and communication cabinets, compliant with CISPR16 and EN50147 with internationally recognized test data.
  2. R&D Center of a Smartphone Brand: KITOZER Class C Basic 3m fully anechoic chamber (9m×6m×6m internal, 2m quiet zone) for radiated emission/immunity testing and antenna calibration of mobile phones, routers and Bluetooth earphones, cost-efficient to satisfy R&D testing demands.

11.3 Medical Device Cases

  1. MRI Center of a Grade-A Tertiary Hospital: KITOZER Class B Medium shielding enclosure with ≥100dB shielding effectiveness to block external electromagnetic interference on MRI equipment and prevent internal radiation leakage, ensuring imaging quality and patient & staff safety.
  2. Precision Instrument Lab of a Medical Equipment Manufacturer: KITOZER Class B Medium 5m fully anechoic chamber with ferrite + wedge absorbers and ≥100dB shielding for EMC testing and calibration of cardiac pacemakers, medical sensors and high-frequency electrosurgical units, compliant with medical EMC standards.

11.4 Automotive Industry Cases

  1. Full-Vehicle EMC Test Center of a New Energy Automaker: KITOZER Class A Premium 10m semi-anechoic chamber (21m×12m×9m internal) equipped with 5t heavy turntable and 10m high-precision antenna tower for full new energy vehicle, BMS and motor controller EMC testing, compliant with GB/T 18387 and ISO 11452 with reliable accurate data.
  2. Component Lab of an Auto Parts Manufacturer: KITOZER Class B Medium 5m semi-anechoic chamber with 3m quiet zone and 500kg turntable for radiation testing of vehicle navigation, radar and ECUs, meeting automotive EMC certification requirements.

11.5 Government & Financial Classified Cases

  1. Classified Computer Room of a Provincial Government: KITOZER Class B Medium assembled shielding enclosure with ≥100dB shielding effectiveness, electric double-knife door and full power/signal filters, anti-wiretapping design eliminating classified electromagnetic leakage to secure government confidential data.
  2. Confidential Zone of a Large Bank Data Center: KITOZER Class B Medium shielding chamber with anti-static grounding and ≥100dB shielding for storage & processing of financial classified data, isolating electromagnetic interference and information leakage risks.

11.6 University & Research Institute Cases

  1. EMC Laboratory of a Double First-Class University Electronic Information School: KITOZER Class B Medium 5m semi-anechoic chamber for both teaching and research, equipped with turntable, antenna tower and demo system for undergraduate experiments, postgraduate research and faculty project development, stable performance and easy operation well-received by faculty and students.
  2. RF R&D Lab of a Research Institute: KITOZER Class C Basic 3m fully anechoic chamber with controlled cost for R&D testing and calibration of RF components & high-frequency circuits, isolating external electromagnetic interference to ensure smooth R&D work.

12. Product Troubleshooting & Maintenance Guide

12.1 Common Faults & Troubleshooting

12.1.1 Degraded Shielding Effectiveness

  • Symptom: Shielding effectiveness test value below standard, excessive electromagnetic leakage
  • Root Causes:
    1. Deformed/oxidized shield door finger strips with poor contact
    2. Cracked shielding enclosure welds, loose module bolts, aged conductive gaskets
    3. Dust accumulation, deformation or loose sealing of ventilation waveguide windows
    4. Loose feed-through panel connectors, failed sealing
    5. Poor grounding connection, excessive grounding resistance
  • Solutions:
    1. Replace deformed/oxidized strips, clean contact surfaces for tight fit
    2. Reweld cracks, fasten bolts, replace aged conductive gaskets
    3. Clean dust, correct deformation and re-seal waveguide windows
    4. Tighten feed-through connectors and replace sealing parts
    5. Clean grounding electrode contact surfaces, fasten connections and adjust grounding resistance to standard range

12.1.2 Loose/Damaged Wave Absorbers

  • Symptom: Loose/falling ferrite tiles, cracked/deformed/fallen wedge absorbers
  • Root Causes:
    1. Weak installation adhesion, aged glue
    2. Excessively high/low ambient temperature & humidity accelerating material aging
    3. Physical collision or equipment transport damage
    4. Improper cleaning or corrosive substance erosion
  • Solutions:
    1. Re-glue and fix, replace aged adhesive
    2. Control ambient temp & humidity within -20℃~+80℃, RH 40%–60%
    3. Avoid physical collision, add protective covers during equipment transport
    4. Clean with neutral detergent only, avoid corrosive chemicals

12.1.3 Shielded Door Operation Failure

  • Symptom: Stiff/jammed manual door; unopenable/unclosable electric/pneumatic door, abnormal noise, remote control failure
  • Root Causes:
    1. Deformed hinges, insufficient lubrication
    2. Foreign matter jamming finger strips
    3. Faulty motor, short circuit or dead remote battery for electric doors
    4. Insufficient air pressure, faulty cylinder or air pipe leakage for pneumatic doors
    5. Deformed door leaf or misaligned door frame
  • Solutions:
    1. Correct hinges and apply lubricant
    2. Clean foreign matter and straighten finger strips
    3. Repair motor & wiring, replace remote batteries
    4. Supplement air pressure, repair cylinders and air pipelines
    5. Straighten door leaf & frame and adjust gaps

12.1.4 Power Filter Malfunction

  • Symptom: No output, abnormal voltage, severe overheating, electric leakage, reduced insertion loss
  • Root Causes:
    1. Damaged internal components (capacitors, inductors, resistors)
    2. Short-circuited or loose input/output wiring
    3. Overload exceeding rated current
    4. Poor ventilation & excessive ambient temperature
    5. Long-term aging and degraded insulation performance
  • Solutions:
    1. Replace damaged components or full filter unit
    2. Repair wiring, fasten connections and eliminate short circuits
    3. Reduce load within rated current range
    4. Improve ventilation and lower ambient temperature
    5. Test insulation periodically, replace heavily aged filters

12.1.5 Turntable/Antenna Tower Malfunction

  • Symptom: Turntable unable to rotate, abnormal speed, positioning error, abnormal noise; antenna tower stuck during lifting, positioning inaccuracy
  • Root Causes:
    1. Faulty drive motor, short-circuited wiring
    2. Worn transmission gears/chains, insufficient lubrication, foreign blockage
    3. Overload beyond rated load capacity
    4. Faulty or misaligned limit switches
    5. Long-term wear and component aging
  • Solutions:
    1. Repair motor & wiring, fasten all connections
    2. Replace worn gears/chains, add lubricant and clear foreign debris
    3. Reduce load to within rated capacity
    4. Repair limit switches and calibrate positions
    5. Periodic overhaul and replacement of aging components

12.2 Routine Maintenance Schedule

12.2.1 Daily Maintenance

  1. Inspect smooth door operation, check finger strips for deformation/oxidation/foreign matter and clean contact surfaces
  2. Check wave absorbers for looseness, detachment and damage, wipe surface dust
  3. Check electrical system for abnormal overheating, noise and indicator light status
  4. Verify ambient temperature & humidity stay within normal range (-20℃~+80℃, RH 40%–60%)
  5. Inspect grounding connections for tightness and rust

12.2.2 Weekly Maintenance

  1. Tighten shielding enclosure module bolts, inspect conductive gaskets for aging
  2. Clean ventilation waveguide window dust and check sealing integrity
  3. Inspect feed-through panel connectors for looseness and sealing performance
  4. Lubricate door hinges, turntable transmission parts and antenna tower lifting rails
  5. Test filter input/output voltage and check for abnormal overheating

12.2.3 Monthly Maintenance

  1. Full shielding effectiveness testing, record data and compare against standards for anomaly troubleshooting
  2. Check adhesion strength of wave absorbers, re-glue loose/fallen units
  3. Inspect electric/pneumatic door motors, cylinders and wiring, clean internal dust
  4. Calibrate turntable rotation positioning and antenna tower lifting accuracy
  5. Clean environmental monitoring sensors and cameras, verify normal operation

12.2.4 Annual Maintenance

  1. Full disassembly inspection of shielded doors, replace aged finger strips and sealing parts, straighten door leaf & frame
  2. Full inspection of shielding enclosure welds and module connections, rework cracked welds and replace aged gaskets
  3. Full performance testing of wave absorbers, replace units with degraded reflection loss
  4. Complete overhaul of power & signal filters, replace aged components and test insertion loss
  5. Full maintenance of turntables and antenna towers, replace worn aging parts and calibrate precision
  6. Comprehensive grounding resistance test, clean grounding electrodes and re-fasten connections to meet resistance limits (≤0.1Ω Premium / ≤0.5Ω Medium / ≤1Ω Basic)

12.2.5 Long-Term Shutdown Maintenance

  1. Cut all power supplies, close shielded doors fully, clean internal dust and debris
  2. Apply anti-rust oil to door finger strips and all metal components to prevent oxidation
  3. Cover wave absorbers with dust cloth to avoid dust accumulation and moisture damage
  4. Monthly ventilation to keep interior dry and prevent mold growth
  5. Monthly inspection of shielded doors, absorbers and electrical systems for timely fault handling

12.3 Maintenance Precautions

  1. Maintenance personnel must receive professional training and hold operation authorization; untrained staff are prohibited from maintenance work
  2. Cut all power before maintenance, hang “No Switch-On” warning signs to prevent electric shock hazards
  3. Corrosive or flammable materials are strictly forbidden inside the chamber to avoid equipment damage or fire risks
  4. Only neutral detergent is allowed for cleaning; strong acid/alkaline cleaners are prohibited to prevent surface corrosion
  5. Avoid striking or colliding shielding enclosures, shielded doors and wave absorbers during maintenance to prevent deformation & breakage
  6. Record all maintenance and test data to build complete equipment maintenance archives for traceability and analysis

13. Factory Strength & After-Sales Service

13.1 Factory Strength

13.1.1 Production Scale & Capacity

KITOZER operates a 10,000㎡ modern manufacturing base located in Guangdong, China, specialized in R&D, production and sales of electromagnetic shielding equipment, wave absorbing materials and testing auxiliary devices as a leading domestic supplier of integrated shielding anechoic chamber solutions.

The factory is equipped with German laser cutters, CNC benders, automatic welding robots, precision grinding equipment and dedicated absorber forming production lines with full automated manufacturing. Annual production capacity reaches 300 sets of shielding chambers, 100,000 pieces of wave absorbers and 5,000 sets of shielded doors & filters to fulfill bulk domestic and international orders.

13.1.2 R&D & Technical Strength

The company employs a 50-person professional R&D team including 10 senior engineers and 20 engineers dedicated to electromagnetic shielding, wave absorbing material and anechoic chamber testing technology research, holding over 20 national patents (5 invention patents, 15 utility model patents) with domestic leading and international advanced technical standards.

Long-term industry-university-research cooperation is established with top domestic universities and research institutes to jointly develop new shielding materials, high-performance absorbers and intelligent testing systems for continuous technical iteration and product optimization.

13.1.3 Quality Control System

The company strictly implements ISO9001 Quality Management System, ISO14001 Environmental Management System and ISO45001 Occupational Health & Safety Management System, building full-process quality control covering raw material procurement, manufacturing, finished product inspection and delivery.

All raw materials pass incoming inspection before warehousing; production adopts first-piece inspection, in-process patrol inspection and 100% finished product inspection with dedicated quality responsibility for each process. Every finished chamber undergoes shielding effectiveness, quiet zone performance and electrical safety testing with third-party authoritative certification reports prior to shipment to guarantee full compliance with quality standards.

13.1.4 Qualifications & Honors

Possess electromagnetic shielding equipment production license, military product quality system certification, High-Tech Enterprise Certificate and full ISO triple-system certification; products comply with GB/T 12190, EN50147-1, GJB5792 and other domestic & international standards.

Awarded titles including China Top 10 Electromagnetic Shielding Brands, Guangdong High-Tech Enterprise, Contract-Abiding & Creditworthy Enterprise and Excellent Military Supplier. Products are sold nationwide and exported to over 50 countries across Southeast Asia, Middle East, Europe and Americas with wide customer recognition.

13.2 After-Sales Service

13.2.1 Service Philosophy

KITOZER adheres to the service tenet of “Customer First, Quality Supreme, Service-Oriented, Continuous Innovation” to deliver one-stop, all-round and round-the-clock after-sales support ensuring stable equipment operation and eliminating customer worries.

13.2.2 Service Network

A nationwide after-sales network covers North, East, South, Southwest and Northwest China with 10 regional service centers and 30 local service outlets staffed by 50 professional service engineers, delivering 24-hour customer response and on-site support. An international service team provides overseas installation, commissioning, training and maintenance for global clients.

13.2.3 Service Scope

  1. Free Design Consultation: Free site survey, customized solution design and technical consulting tailored to customer testing demands
  2. Free Installation & Commissioning: Professional teams conduct full on-site assembly, debugging and performance tuning to reach all designed technical indicators
  3. Free Technical Training: Hands-on training for customer operators covering equipment operation, daily maintenance and basic fault troubleshooting
  4. Warranty Policy: 2-year free full product warranty counting from acceptance date. Non-artificial faults during warranty period enjoy free repair, component replacement and on-site service at no charge
  5. Lifelong Maintenance: Paid maintenance support post-warranty with discounted spare parts supply; 24-hour fault response and rapid on-site repair to extend equipment service life
  6. Regular Follow-Up: Monthly/quarterly telephone and on-site visits to inspect equipment operation, deliver maintenance recommendations and resolve hidden issues timely
  7. Equipment Upgrade Service: Modification & performance upgrade to match evolving customer testing demands and expand functional capacity

13.2.4 Service Commitment

  1. 24-Hour Response Guarantee: 1-hour initial reply upon fault report, solution proposal within 4 hours, on-site service within 24 hours (urban areas) / 48 hours (suburban & remote regions)
  2. Quality Commitment: All products fully comply with national, industrial and contractual specifications. Full return/exchange and loss compensation for confirmed factory quality defects
  3. Confidentiality Commitment: Strict non-disclosure of customer technical data, project information and commercial details with no unauthorized disclosure to third parties
  4. Transparent Pricing Commitment: Open and reasonable product pricing with no hidden fees; discounted spare parts and maintenance fees post-warranty without arbitrary price hikes

14. Conclusion

KITOZER shielded anechoic chamber represents a flagship integrated solution provider in electromagnetic shielding and anechoic testing industries…

15. Search Keywords & SEO Tag System

15.1 Core Primary Keywords

Shielded Anechoic Chamber, Electromagnetic Shielded Chamber, Microwave Anechoic Chamber, Shielded Computer Room, EMC Shielded Chamber, Fully Anechoic Chamber, Semi-Anechoic Chamber, Classified Shielded Room, KITOZER Shielded Anechoic Chamber

15.2 High-Converting Long-Tail Keywords

Shielded Anechoic Chamber Solution, Custom Electromagnetic Shielded Chamber, Microwave Anechoic Chamber Manufacturer, Shielded Computer Room Design & Construction, EMC Test Shielded Chamber, Fully Anechoic Chamber Quiet Zone Index, Military-Grade Shielded Chamber, Classified Information Shielded Room, Factory Direct Shielded Anechoic Chamber, Shielded Chamber Price, Shielded Chamber Technical Parameters, Shielded Chamber Tender Control Parameters, Shielded Chamber Maintenance Guide, Shielded Chamber Engineering Cases, Automotive Electronic Shielded Chamber, 5G Communication Shielded Chamber, Assembled Shielded Chamber

15.3 Industry Traffic Keywords

Electromagnetic Shielding Technology, EMC Testing, Microwave Wave Absorbing Material, Shielding Effectiveness Test, Faraday Cage Shielded Room, EMC Laboratory Construction, Antenna Test Chamber, RF Shielding Engineering, Industrial Electromagnetic Shielding, Computer Room Shielding Renovation, Classified Computer Room Construction, Electromagnetic Leakage Protection, Anti-Electromagnetic Interference, Shielded Room Standards, Anechoic Chamber Quiet Zone Testing

15.4 Brand Exclusive Keywords

KITOZER Shielded Anechoic Chamber, Lai’an Intelligent Shielded Computer Room, Guangzhou Lai’an Shielded Chamber, KITOZER Pioneer Shielded Room, Lai’an Intelligent Electromagnetic Shielding, KITOZER Microwave Anechoic Chamber, Lai’an Classified Shielded Room, KITOZER Shielded Chamber Manufacturer, Lai’an Intelligent EMC Chamber, KITOZER Shielding Solution

15.5 Drop-Down & Related Search Keywords

What is a shielded anechoic chamber, function of shielded anechoic chamber, composition of shielded anechoic chamber, classification of shielded anechoic chamber, reliable shielded chamber supplier, shielded chamber national standards, shielded chamber installation guide, standard sizes of shielded anechoic chamber, shielding effectiveness standard, wave absorbing material for shielding chamber, grounding requirements for shielding room, filter configuration for shielded chamber, shielding chamber construction specification, shielding chamber acceptance criteria, shielded chamber after-sales service

15.6 SEO Optimization Tag System

(1) Core Page Optimization Tags

  • Page Title: Shielded Anechoic Chamber | Electromagnetic Shielded Chamber | Microwave Anechoic Chamber | Integrated Solution – Guangzhou Lai’an Intelligent KITOZER
  • Page Keywords: Shielded Anechoic Chamber, Electromagnetic Shielded Chamber, Microwave Anechoic Chamber, Shielded Computer Room, Classified Shielded Room, EMC Test Chamber, Lai’an Intelligent, KITOZER
  • Page Meta Description: Guangzhou Lai’an Intelligent delivers full integrated solutions for KITOZER shielded anechoic chambers, electromagnetic shielding chambers and microwave anechoic chambers covering design, manufacturing, installation and after-sales service. Full shielding effectiveness coverage from 10kHz to 18GHz with fully customizable military-grade products and nationwide on-site service.

(2) Internal Link Anchor Text Tags

Core Anchor Texts: Shielded Anechoic Chamber Solution, Shielded Chamber Manufacturer, Shielded Computer Room Design, Custom Electromagnetic Shielded Chamber, KITOZER Shielded Anechoic Chamber

Shopping Cart