The KITOZER shielded container is an industrial special protective equipment integrating electromagnetic shielding technology and modular container structures. Designed in compliance with standards including GB/T 12190-2021, EN 50147-1 and IEEE 299, it forms a highly airtight electromagnetic protection space via a hexahedral fully welded shielding structure, dedicated electromagnetic shielding components and filtering systems.
The product blocks external electromagnetic waves such as WiFi, Bluetooth, 5G and GPS from penetrating, while suppressing internal electromagnetic signal leakage. Its shielding effectiveness covers the frequency band of 30MHz–18GHz; standard models achieve ≥70dB, and military-grade variants reach over 90dB, meeting high-confidentiality requirements such as TEMPEST and SDIP.
As an integrated protection system deployable at high speed, the KITOZER shielded container adopts standard ISO 20ft/40ft dimensions, compatible with land and sea transportation. It supports long-term operation in harsh open-air environments, temporary camps, field base stations and other complex sites, featuring waterproof, dustproof, shockproof and corrosion-resistant properties with an operating ambient temperature range of -40℃ to +55℃.
The system integrates six subsystems: structural, shielding, ventilation & filtering, electrical control, security monitoring and auxiliary supporting systems. Prefabricated and commissioned in factory, it only requires foundation fixing and external power supply on-site, enabling deployment within 3 days and delivery within 20 days. Widely applied in national defense, electronic testing, data computer rooms, confidential offices, nuclear industry and other fields, it serves as core equipment for mobile and modular electromagnetic protection.
2. System Composition
The KITOZER shielded container consists of six core subsystems that work in coordination to guarantee shielding performance and operational stability: main structural system, electromagnetic shielding system, ventilation filtering system, electrical control system, security monitoring system and auxiliary supporting system.
2.1 Main Structural System
- Container Enclosure: Standard 20ft/40ft high cube / general cube with fully welded hexahedral structure. Base material: 5mm galvanized steel plate with external anti-corrosion coating and internal insulation treatment.
- Shielding Layer: 2.0mm cold-rolled steel shielding plate with seamless welding to form a continuous conductive shielding cavity. The interlayer is filled with 50mm flame-retardant rock wool thermal insulation (Class A fire resistance).
- Load-bearing Frame: High-strength channel steel uprights and cross beams with load capacity ≥2000kg/㎡, meeting equipment stacking and hoisting transportation requirements.
2.2 Electromagnetic Shielding System
- Electromagnetic Shielded Door: Manual sliding / hinged type, size 900×2000mm, sealed with three-layer bronze-plated spring reeds in knife-edge design, locking pressure ≥300kg, matching the cabinet’s shielding effectiveness.
- Shielded Waveguide Window: Honeycomb type, size 600×400mm, cutoff frequency ≤1GHz, ventilation capacity ≥0.25m²/s, light transmittance ≥80%, preventing electromagnetic wave leakage through ventilation openings.
- Shielded Joint Components: Special conductive sealing strips, shielding rivets and grounding connectors to eliminate gaps at cabinet joints and restrain electromagnetic leakage.
2.3 Ventilation & Filtering System
- Explosion-proof shielded ventilators: Matched with waveguide windows to realize air exchange while blocking electromagnetic signals.
- Power Filters: Dedicated three-phase / single-phase filters to suppress conducted interference on power lines, with insertion loss ≥100dB from 100kHz to 10GHz.
- Signal Filters: Special filters for network, fiber and video signals to ensure signal transmission while shielding electromagnetic interference.
2.4 Electrical Control System
- Intelligent Power Distribution Cabinet: 8-circuit design integrating leakage protection, overload protection and 20kA lightning surge protection, supporting remote monitoring.
- Lighting System: 40W anti-glare LED flat panels with illuminance ≥300lux and IP54 protection grade, suitable for harsh environments.
- Grounding System: Dedicated shielding grounding device with grounding resistance ≤4Ω to ensure personnel and equipment safety.
2.5 Security Monitoring System
- Environmental Monitoring: Temperature, humidity, smoke and water immersion sensors to monitor cabin conditions in real time and trigger alarms for abnormalities.
- Video Surveillance: High-definition infrared cameras with IP66 protection for remote viewing.
- Access Control: Three-in-one fingerprint / card swiping / password access controller that records entry-exit logs to prevent unauthorized access.
2.6 Auxiliary Supporting System
- Anti-static Flooring: 600×600×35mm PVC surface with resistance 1×10⁶–1×10¹⁰Ω and load capacity ≥1200kg/㎡.
- Thermal Insulation Layer: 50mm Class A flame-retardant rock wool to reduce heat transfer and energy consumption.
- Emergency System: Emergency lighting, escape indicators and dry powder fire extinguishers complying with safety specifications.
3. System Classification
KITOZER shielded containers are categorized by four dimensions: protection grade, application scenario, structural form and shielding effectiveness, covering full demand tiers from low to high with customizable adjustments.
3.1 Classification by Shielding Effectiveness
- Basic Type (Low Protection): Shielding effectiveness ≥60dB (30MHz–1GHz), suitable for general electronic computer rooms, confidential offices and small-scale testing scenarios.
- Standard Type (Medium Protection): Shielding effectiveness ≥70dB (30MHz–18GHz), applicable to military temporary command posts, medium-sized data disaster recovery and routine electromagnetic testing.
- Military Type (High Protection): Shielding effectiveness ≥90dB (10kHz–40GHz), meeting TEMPEST, nuclear industry, aerospace and other high-confidentiality, strong electromagnetic interference scenarios.
3.2 Classification by Size Specification
- 20ft Standard Model: External dimension 6058×2438×2591mm, internal dimension 5900×2345×2400mm, small footprint and flexible transportation.
- 40ft Standard Model: External dimension 12192×2438×2591mm, internal dimension 12032×2345×2400mm, spacious for integrated multi-equipment deployment.
- Custom Non-standard Model: Custom non-ISO sizes such as 10ft, 30ft or special-shaped structures for unique site and equipment requirements.
3.3 Classification by Application Scenario
- Electromagnetic Testing Type: For EMI/EMC testing of electronic devices, radio frequency testing and laboratory isolation, equipped with high-precision shielding and filtering components.
- Data Computer Room Type: For edge computing, mobile data centers and disaster recovery computer rooms, integrated with UPS, precision air conditioners and cabinet arrays.
- Military Confidential Type: For field command posts, communication hubs and confidential offices, with enhanced explosion-proof, shockproof and anti-interference performance.
- Special Protection Type: For nuclear industrial waste storage, medical radiation shielding and hazardous material isolation, with additional radiation shielding and anti-corrosion layers.
3.4 Classification by Structural Form
- Fixed Type: Fully welded sealed structure for long-term fixed-site use with stable shielding performance.
- Modular Spliced Type: Split design for on-site assembly, ideal for frequent relocation and temporary deployment.
- Expandable Type: Single-side / double-side expandable structure that expands usable space by 50%–100%, balancing transport portability and usable area.
4. System Schematic Diagram
The core working principle of the KITOZER shielded container system relies on a hexahedral fully enclosed shielding cavity, multi-node electromagnetic leakage blocking and multi-stage filtering protection. Three layers of protection (structural shielding, joint shielding and port filtering) achieve bidirectional isolation of electromagnetic signals.
4.1 Shielding Cavity Principle
Adopting Faraday electromagnetic shielding theory, the continuous conductive metal cavity (cold-rolled steel shielding layer) generates reflection and absorption loss for incident electromagnetic waves: low-frequency waves rely mainly on reflection loss, while high-frequency waves rely on absorption loss, ultimately fully isolating electromagnetic signals inside and outside the cabin. The seamless hexahedral welding eliminates splicing gaps of the cabinet, eradicating electromagnetic leakage paths at the source.
4.2 Joint & Port Shielding Principle
- Joint Shielding: Conductive elastic sealing components (bronze-plated spring reeds, conductive sealing strips) are used at cabinet joints and door seals to ensure continuous conductivity of mating surfaces, creating reflection and propagation loss for electromagnetic waves passing through gaps to suppress leakage.
- Ventilation Port Shielding: Honeycomb waveguide windows leverage waveguide cutoff characteristics to produce extreme attenuation for electromagnetic waves above the cutoff frequency, only allowing air circulation while blocking signal leakage through vents.
- Cable Port Shielding: Dedicated filters are installed at power and signal cable entry points. Power filters suppress conducted interference, and signal filters preserve signal transmission while blocking electromagnetic interference, preventing cables from becoming electromagnetic leakage channels.
4.3 System Operation Flow Schematic
- External electromagnetic signals (5G, WiFi, radar waves, etc.) → Cabinet metal shielding layer (reflection + absorption, loss ≥70dB) → Residual signals → Joint sealing components (secondary attenuation) → Ventilation waveguide windows / cable filters (tertiary attenuation) → No electromagnetic signals penetrate into the cabin.
- Internal electromagnetic signals (equipment radiation, confidential signals, etc.) → Pass reversely through shielding layers / sealing components / filters → External signal strength ≤-100dBm, undetectable by external devices.
- Electrical power → Power filter → Power distribution cabinet → Internal equipment; meanwhile, the grounding system diverts stray current to ground for safety.
- Environmental / security sensors → Monitoring host → Local display + remote transmission, real-time cabin status monitoring with linked alarms for abnormalities.
5. Full System Configuration List (3 Tiers: Basic / Standard / Military, KITOZER Brand)
5.1 Basic Low-Tier Model (20ft, Shielding ≥60dB)
表格
| No. | Product Name | Model & Spec | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Shielded Container Enclosure | KITOZER-SC20-L | 20ft standard size, 6058×2438×2591mm, 5mm galvanized steel + 2.0mm cold-rolled steel shielding layer, shielding ≥60dB (30MHz–1GHz), Class A fireproof rock wool insulation | 1 | Set | KITOZER | Basic anti-corrosion coating |
| 2 | Electromagnetic Shielded Door | KITOZER-SD9020-L | 900×2000mm hinged, single-layer reed seal, locking pressure ≥200kg, shielding ≥60dB | 1 | Leaf | KITOZER | Including lock and sealing strips |
| 3 | Shielded Waveguide Window | KITOZER-WG6040-L | 600×400mm honeycomb, cutoff frequency ≤1.5GHz, ventilation ≥0.2m²/s | 2 | Pcs | KITOZER | Matched with ventilators |
| 4 | Shielded Ventilator | KITOZER-FT300-L | Explosion-proof, air volume 300m³/h, IP54 protection, matched with waveguide window | 2 | Pcs | KITOZER | Manual control |
| 5 | Power Filter | KITOZER-PF380-10-L | 3-phase 380V/10A, insertion loss ≥60dB (100kHz–1GHz) | 1 | Set | KITOZER | Basic filtering |
| 6 | Intelligent Power Distribution Cabinet | KITOZER-EC8-L | 8 circuits, leakage / overload protection, 10kA surge protection, indicator display | 1 | Set | KITOZER | Wall-mounted |
| 7 | LED Flat Panel Light | KITOZER-LT40-L | 40W, 600×600mm, illuminance ≥250lux, IP54 | 4 | Pcs | KITOZER | With mounting accessories |
| 8 | Anti-static Flooring | KITOZER-ES6035-L | 600×600×35mm, PVC surface, resistance 1×10⁸–1×10¹⁰Ω, load ≥1000kg/㎡ | 12 | ㎡ | KITOZER | With supports and cross beams |
| 9 | Grounding Kit | KITOZER-GS-L | Ground copper bar + grounding wire, grounding resistance ≤4Ω | 1 | Set | KITOZER | Including ground electrodes |
| 10 | Environmental Sensor | KITOZER-TH-L | Integrated temperature & humidity, temp range -20℃~+60℃, humidity 0–100% RH | 2 | Pcs | KITOZER | Basic monitoring |
5.2 Standard Mid-Tier Model (20ft, Shielding ≥70dB)
表格
| No. | Product Name | Model & Spec | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Shielded Container Enclosure | KITOZER-SC20-M | 20ft standard size, 6058×2438×2591mm, 5mm galvanized steel + 2.0mm cold-rolled steel shielding layer, shielding ≥70dB (30MHz–18GHz), Class A fireproof rock wool, reinforced anti-corrosion coating | 1 | Set | KITOZER | Outdoor weather-resistant, anti-rust ≥5 years |
| 2 | Electromagnetic Shielded Door | KITOZER-SD9020-M | 900×2000mm sliding, three-layer bronze-plated reed seal, locking pressure ≥300kg, shielding ≥70dB | 1 | Leaf | KITOZER | With electric push rod and sealing strips |
| 3 | Shielded Waveguide Window | KITOZER-WG6040-M | 600×400mm honeycomb, cutoff frequency ≤1GHz, ventilation ≥0.25m²/s, light transmittance ≥80% | 2 | Pcs | KITOZER | High shielding efficiency |
| 4 | Shielded Ventilator | KITOZER-FT500-M | Explosion-proof, air volume 500m³/h, IP55 protection, temp-controlled auto start-stop | 2 | Pcs | KITOZER | Automatic control |
| 5 | Power Filter | KITOZER-PF380-20-M | 3-phase 380V/20A, insertion loss ≥80dB (100kHz–10GHz) | 1 | Set | KITOZER | High-efficiency filtering |
| 6 | Signal Filter | KITOZER-SF-RJ45-M | Dedicated for network signals, RJ45 interface, insertion loss ≥70dB (1MHz–1GHz) | 4 | Pcs | KITOZER | Matched with network equipment |
| 7 | Intelligent Power Distribution Cabinet | KITOZER-EC8-M | 8 circuits, leakage / overload / phase loss protection, 20kA surge protection, LCD display, remote communication | 1 | Set | KITOZER | Floor-standing |
| 8 | LED Flat Panel Light | KITOZER-LT40-M | 40W, 600×600mm, anti-glare, illuminance ≥300lux, IP54 | 4 | Pcs | KITOZER | Energy-saving high brightness |
| 9 | Anti-static Flooring | KITOZER-ES6035-M | 600×600×35mm, PVC surface, resistance 1×10⁶–1×10⁹Ω, load ≥1200kg/㎡ | 12 | ㎡ | KITOZER | Wear-resistant anti-static |
| 10 | Multi-function Environmental Sensor | KITOZER-THSW-M | Temp + humidity + smoke + water immersion, temp -40℃~+55℃, humidity 0–100% RH, linked smoke / water immersion alarm | 4 | Pcs | KITOZER | Full-dimensional monitoring |
| 11 | HD Infrared Camera | KITOZER-CAM-M | 2MP, infrared night vision, IP66 protection, remote viewing support | 2 | Pcs | KITOZER | Outdoor waterproof |
| 12 | Access Control Controller | KITOZER-AC-M | Fingerprint / card / password three-in-one, stores 1000 entry-exit logs | 1 | Set | KITOZER | Including card reader and lock |
| 13 | Grounding Kit | KITOZER-GS-M | Pure copper ground bar + multi-strand grounding wire, grounding resistance ≤4Ω, anti-corrosion treatment | 1 | Set | KITOZER | High-efficiency grounding |
5.3 Military High-Tier Model (40ft, Shielding ≥90dB)
表格
| No. | Product Name | Model & Spec | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Shielded Container Enclosure | KITOZER-SC40-H | 40ft high cube, 12192×2438×2896mm, 6mm galvanized steel + 2.5mm cold-rolled steel shielding layer, shielding ≥90dB (10kHz–40GHz), Class A fireproof rock wool, military anti-corrosion coating, explosion-proof reinforcement | 1 | Set | KITOZER | Military standard, shock & explosion resistant |
| 2 | Electromagnetic Shielded Door | KITOZER-SD1022-H | 1000×2200mm sliding, five-layer bronze-plated reed seal, locking pressure ≥500kg, shielding ≥90dB, explosion-proof lock | 1 | Leaf | KITOZER | Military-grade sealing |
| 3 | Shielded Waveguide Window | KITOZER-WG8050-H | 800×500mm honeycomb, cutoff frequency ≤500MHz, ventilation ≥0.3m²/s, light transmittance ≥85% | 3 | Pcs | KITOZER | Ultra-high shielding efficiency |
| 4 | Shielded Ventilator | KITOZER-FT1000-H | Explosion-proof anti-corrosion, air volume 1000m³/h, IP65 protection, temp + remote start-stop, redundant backup | 4 | Pcs | KITOZER | Dual-system backup |
| 5 | Power Filter | KITOZER-PF380-50-H | 3-phase 380V/50A, insertion loss ≥100dB (100kHz–10GHz), military grade | 1 | Set | KITOZER | Full-band filtering |
| 6 | Signal Filter | KITOZER-SF-RJ45-H+SF-FIBER-H | Dedicated for network + fiber signals, RJ45 / fiber interface, insertion loss ≥90dB (1MHz–40GHz) | 8/2 | Pcs | KITOZER | Full-type signal filtering |
| 7 | Intelligent Power Distribution Cabinet | KITOZER-EC12-H | 12 circuits, leakage / overload / phase loss / overvoltage protection, 40kA surge protection, touch screen display, remote monitoring + redundant power supply | 1 | Set | KITOZER | Military power distribution |
| 8 | LED Flat Panel Light | KITOZER-LT50-H | 50W, 600×600mm, anti-glare explosion-proof, illuminance ≥350lux, IP65 | 8 | Pcs | KITOZER | Explosion-proof high brightness |
| 9 | Anti-static Flooring | KITOZER-ES6040-H | 600×600×40mm, PVC surface, resistance 1×10⁶–1×10⁸Ω, load ≥1500kg/㎡, explosion-proof | 24 | ㎡ | KITOZER | Military anti-static |
| 10 | Full-dimensional Environmental Sensor | KITOZER-THSWP-H | Temp + humidity + smoke + water immersion + air pressure, temp -40℃~+55℃, humidity 0–100% RH, linked fire control / ventilation system | 8 | Pcs | KITOZER | All-parameter monitoring |
| 11 | HD Infrared Explosion-proof Camera | KITOZER-CAM-H | 4MP, infrared night vision, IP68 explosion-proof, 4K transmission, remote PTZ control | 4 | Pcs | KITOZER | Military explosion-proof |
| 12 | Military Access Control Controller | KITOZER-AC-H | Fingerprint / card / password / facial recognition four-in-one, encrypted storage, anti-pry alarm, remote authorization | 1 | Set | KITOZER | Including explosion-proof reader and lock |
| 13 | Grounding Kit | KITOZER-GS-H | Silver-plated pure copper ground bar + shielding grounding wire, grounding resistance ≤1Ω, anti-corrosion & anti-interference | 1 | Set | KITOZER | Military-grade grounding |
| 14 | Emergency System | KITOZER-ES-H | Emergency lighting, escape indicators, 2×4kg dry powder fire extinguishers, emergency power cut-off switch | 1 | Set | KITOZER | Military safety standard |
| 15 | Precision Air Conditioner | KITOZER-ACU-H | Cooling capacity 12kW, temp control range 18–28℃, accuracy ±0.5℃, IP54, redundant backup | 2 | Set | KITOZER | Constant temperature & humidity |
6. Full Product Technical Specifications
6.1 Shielded Container Enclosure (All Series)
- Brand: KITOZER
- Models: SC20-L/M, SC40-H
- Dimensions: 20ft (6058×2438×2591mm), 40ft (12192×2438×2896mm)
- Material: 5–6mm galvanized steel (outer layer) + 2.0–2.5mm cold-rolled steel (shielding layer)
- Shielding Effectiveness:
- Basic: ≥60dB (30MHz–1GHz)
- Standard: ≥70dB (30MHz–18GHz)
- Military: ≥90dB (10kHz–40GHz)
- Insulation Layer: 50mm flame-retardant rock wool, Class A fire resistance, thermal conductivity ≤0.04W/(m·K)
- Protection Grade: Basic ≥IP54, Standard ≥IP55, Military ≥IP65
- Ambient Temperature: -40℃ ~ +55℃
- Load Capacity: Basic ≥1000kg/㎡, Standard ≥1200kg/㎡, Military ≥1500kg/㎡
6.2 Electromagnetic Shielded Door (All Series)
- Brand: KITOZER
- Models: SD9020-L/M, SD1022-H
- Dimensions: 900×2000mm (Basic / Standard), 1000×2200mm (Military)
- Sealing Structure: Single-layer reed (Basic), three-layer bronze-plated reed (Standard), five-layer bronze-plated reed (Military)
- Locking Pressure: Basic ≥200kg, Standard ≥300kg, Military ≥500kg
- Shielding Effectiveness: Consistent with matching cabinet
- Opening Mode: Hinged (Basic), Sliding (Standard / Military)
- Protection Grade: Basic ≥IP54, Standard ≥IP55, Military ≥IP65
6.3 Shielded Waveguide Window (All Series)
- Brand: KITOZER
- Models: WG6040-L/M, WG8050-H
- Dimensions: 600×400mm (Basic / Standard), 800×500mm (Military)
- Structure: Honeycomb metal waveguide core, aluminum alloy frame
- Cutoff Frequency: Basic ≤1.5GHz, Standard ≤1GHz, Military ≤500MHz
- Ventilation Capacity: Basic ≥0.2m²/s, Standard ≥0.25m²/s, Military ≥0.3m²/s
- Light Transmittance: Basic ≥70%, Standard ≥80%, Military ≥85%
- Shielding Effectiveness: Basic ≥60dB, Standard ≥70dB, Military ≥90dB
6.4 Power Filter (All Series)
- Brand: KITOZER
- Models: PF380-10-L, PF380-20-M, PF380-50-H
- Input Voltage: 3-phase 380V/50Hz
- Rated Current: 10A (Basic), 20A (Standard), 50A (Military)
- Insertion Loss:
- Basic: ≥60dB (100kHz–1GHz)
- Standard: ≥80dB (100kHz–10GHz)
- Military: ≥100dB (100kHz–10GHz)
- Operating Temperature: -25℃ ~ +85℃
- Protection Grade: IP54
6.5 Anti-static Flooring (All Series)
- Brand: KITOZER
- Models: ES6035-L/M, ES6040-H
- Size: 600×600mm
- Thickness: 35mm (Basic / Standard), 40mm (Military)
- Surface Material: Wear-resistant PVC surface
- Surface Resistance:
- Basic: 1×10⁸–1×10¹⁰Ω
- Standard: 1×10⁶–1×10⁹Ω
- Military: 1×10⁶–1×10⁸Ω
- Load Capacity: Basic ≥1000kg/㎡, Standard ≥1200kg/㎡, Military ≥1500kg/㎡
- Fire Rating: Class B1
6.6 Intelligent Power Distribution Cabinet (All Series)
- Brand: KITOZER
- Models: EC8-L/M, EC12-H
- Circuit Count: 8 circuits (Basic / Standard), 12 circuits (Military)
- Protection Functions: Leakage / overload protection (Basic); add phase loss protection (Standard); add overvoltage protection (Military)
- Surge Protection: Basic ≥10kA, Standard ≥20kA, Military ≥40kA
- Display Mode: Indicator lights (Basic), LCD screen (Standard), touch screen (Military)
- Communication Function: None (Basic), remote communication (Standard), remote monitoring + redundant power supply (Military)
- Protection Grade: IP54
6.7 Environmental Monitoring Sensor (All Series)
- Brand: KITOZER
- Models: TH-L, THSW-M, THSWP-H
- Monitored Parameters:
- Basic: Temperature & humidity
- Standard: Temperature & humidity + smoke + water immersion
- Military: Temperature & humidity + smoke + water immersion + air pressure
- Temperature Range: -20℃~+60℃ (Basic), -40℃~+55℃ (Standard / Military)
- Humidity Range: 0–100% RH
- Output Signal: RS485 (Basic / Standard), RS485 + Ethernet (Military)
- Protection Grade: IP54 (Basic / Standard), IP65 (Military)
7. Full Product Application Scope
7.1 Shielded Container Enclosure
- National Defense: Field command posts, communication hubs, confidential offices, weapon storage.
- Electronic Testing: EMI/EMC testing labs, radio frequency testing, antenna testing, chip isolation chambers.
- Data Computer Rooms: Edge computing nodes, mobile data centers, disaster recovery rooms, small cabinet clusters.
- Confidential Offices: Government confidential departments, enterprise R&D centers, financial data processing centers, confidential meeting rooms.
- Special Protection: Nuclear waste storage, medical radiation shielding, hazardous material isolation, electromagnetic sensitive areas.
- Emergency Scenarios: Disaster emergency command, temporary field offices, cabin hospitals, mobile base stations.
7.2 Electromagnetic Shielded Door
- Matches entrances of shielded containers, shielded machine rooms and shielded labs to block electromagnetic leakage at doorways.
- Dedicated shielded doors for military confidential sites, electronic testing labs and confidential meeting rooms to guarantee space shielding effectiveness.
7.3 Shielded Waveguide Window
- Vent port shielding for shielded containers and shielded machine rooms, balancing heat dissipation and electromagnetic shielding.
- Observation / ventilation windows for electronic & RF labs to block wave leakage through windows.
7.4 Power / Signal Filters
- Power Filters: Line filtering for shielding systems, precision electronic and military equipment to suppress conducted interference.
- Signal Filters: Filter network, fiber and video lines to preserve signal transmission while shielding electromagnetic interference.
7.5 Anti-static Flooring
- Ground anti-static treatment for shielded container machine rooms, electronic testing labs, precision instrument workshops and data centers.
- Military electronic workshops, chip production workshops and communication equipment rooms to prevent electrostatic discharge damage to equipment.
7.6 Intelligent Power Distribution Cabinet / Monitoring Sensors
- Power Distribution Cabinet: Power control for shielded containers, industrial shelters and mobile machine rooms to ensure stable electrical safety.
- Sensors: Environmental monitoring for shielded containers, machine rooms and labs, real-time tracking of temperature, humidity, smoke and water immersion to secure equipment operation.
8. Full Product Advantages
8.1 Core Functional Advantages
- High Shielding Effectiveness: Full series ≥60dB shielding efficiency, military models exceed 90dB, blocking all electromagnetic waves and complying with TEMPEST, SDIP and other high-confidentiality standards.
- Full-scenario Adaptability: Standard 20ft/40ft sizes compatible with land & sea transport, long-term outdoor operation at -40℃~+55℃, waterproof, dustproof, shockproof and corrosion-resistant.
- Rapid Deployment: Factory prefabricated and commissioned, only foundation fixing and external power supply required on-site; deployable within 3 days, delivered within 20 days for fast emergency response.
- Integrated All-in-one Design: Integrated structural, shielding, ventilation, electrical and security subsystems, plug-and-play without complex extra construction.
8.2 Customization & OEM Advantages
- Deep Customization: Support non-standard sizes, special-shaped structures, customized shielding effectiveness and dedicated interfaces for unique site & equipment needs.
- Functional Customization: Add explosion-proof, radiation shielding, constant temperature & humidity, remote control, AI intelligent monitoring and other functions for military, nuclear and medical special scenarios.
- OEM/ODM Service: Provide OEM & ODM processing, customer brand labeling, exclusive parameter customization and mass production to guarantee consistent product quality and delivery efficiency.
8.3 Quality & Supply Advantages
- Military-Grade Quality: Manufactured per GB/T 12190-2021, EN 50147-1, IEEE 299 and other standards; core components adopt military-grade materials with service life ≥15 years.
- Confidentiality Guarantee: Strict confidentiality during production; independently developed core technology to prevent technical leakage, suitable for confidential projects.
- In-stock Supply: Standard basic & mid-tier 20ft/40ft models held in inventory, shippable within 7 days for urgent projects.
- Full-series Coverage: Complete product lineup from basic 60dB to military 90dB, 20ft to 40ft, providing one-stop electromagnetic shielding solutions.
8.4 Technical Parameter Advantages
- Wide-band Shielding: Covers 10kHz–40GHz full frequency band, compatible with all mainstream electromagnetic waves including 5G, WiFi, Bluetooth and radar signals.
- Low-leakage Design: Seamless hexahedral welding, three/five-layer reed sealing and multi-stage filtering limit electromagnetic leakage ≤-100dBm, undetectable externally.
- Stable Operation: Shielding effectiveness remains undegraded at -40℃~+55℃, electrical systems run stably with failure rate ≤0.1%.
- High Load Capacity: Cabinet load ≥1000kg/㎡ to support stacked equipment for machine room and testing scenarios.
9. Bid-winning Tender Parameters (Marked with ★)
9.1 Shielded Container Enclosure
★1. Shielding Effectiveness: Basic ≥60dB (30MHz–1GHz), Standard ≥70dB (30MHz–18GHz), Military ≥90dB (10kHz–40GHz). ★2. Cabinet Material: Outer layer 5–6mm galvanized steel, inner shielding layer 2.0–2.5mm cold-rolled steel, fully welded hexahedral structure. ★3. Insulation Layer: 50mm flame-retardant rock wool, Class A fire resistance, thermal conductivity ≤0.04W/(m·K). ★4. Protection Grade: Basic ≥IP54, Standard ≥IP55, Military ≥IP65. ★5. Ambient Temperature: -40℃~+55℃, shielding effectiveness remains undegraded under extreme temperatures.
9.2 Electromagnetic Shielded Door
★1. Sealing Structure: Single-layer reed (Basic), three-layer bronze-plated reed (Standard), five-layer bronze-plated reed (Military). ★2. Locking Pressure: Basic ≥200kg, Standard ≥300kg, Military ≥500kg. ★3. Shielding Effectiveness: Matches corresponding cabinet without leakage.
9.3 Shielded Waveguide Window
★1. Cutoff Frequency: Basic ≤1.5GHz, Standard ≤1GHz, Military ≤500MHz. ★2. Ventilation Capacity: Basic ≥0.2m²/s, Standard ≥0.25m²/s, Military ≥0.3m²/s. ★3. Shielding Effectiveness: Basic ≥60dB, Standard ≥70dB, Military ≥90dB.
9.4 Power Filter
★1. Insertion Loss: Basic ≥60dB (100kHz–1GHz), Standard ≥80dB (100kHz–10GHz), Military ≥100dB (100kHz–10GHz). ★2. Rated Current: Basic 10A, Standard 20A, Military 50A, matching equipment of different power ratings.
9.5 Anti-static Flooring
★1. Surface Resistance: Basic 1×10⁸–1×10¹⁰Ω, Standard 1×10⁶–1×10⁹Ω, Military 1×10⁶–1×10⁸Ω. ★2. Load Capacity: Basic ≥1000kg/㎡, Standard ≥1200kg/㎡, Military ≥1500kg/㎡.
9.6 Intelligent Power Distribution Cabinet
★1. Surge Protection: Basic ≥10kA, Standard ≥20kA, Military ≥40kA. ★2. Protection Functions: Basic includes leakage / overload protection; Standard adds phase loss protection; Military adds overvoltage protection.
10. Full Product Solution Packages
10.1 Military Confidential Scenario Solution
- Pain Points: Complex field environments, strong electromagnetic interference, high information confidentiality requirements, rapid deployment demand, extreme environment resistance.
- Recommended Configuration: 40ft Military High-tier shielded container (KITOZER-SC40-H) + military-grade shielded door + full-band filters + explosion-proof cameras + facial recognition access control + precision air conditioners.
- Solution Advantages: ≥90dB shielding blocks full-band electromagnetic signals; military explosion-proof, shockproof and anti-corrosion design adapts to -40℃~+55℃ extreme field environments; facial recognition access control with encrypted storage ensures confidential information safety; precision air conditioners maintain constant temperature & humidity for precision equipment; deployable within 3 days on-site for emergency command needs.
- Application Scenarios: Field command posts, communication hubs, confidential offices, weapon storage, field confidential meeting rooms.
10.2 Electronic Testing Laboratory Solution
- Pain Points: Need to isolate external electromagnetic interference, prevent internal test signal leakage, guarantee test accuracy, balance ventilation heat dissipation and shielding.
- Recommended Configuration: 20ft Standard Mid-tier shielded container (KITOZER-SC20-M) + high-performance shielding waveguide windows + signal filters + anti-static flooring + temperature & humidity sensors.
- Solution Advantages: ≥70dB shielding meets EMI/EMC and RF testing accuracy requirements; honeycomb waveguide windows balance ventilation and shielding; signal filters eliminate interference for test signal transmission; anti-static flooring prevents electrostatic damage to precision testing instruments; real-time temperature & humidity monitoring stabilizes test environments.
- Application Scenarios: EMI/EMC testing labs, RF testing, antenna testing, chip isolation chambers, precision instrument testing rooms.
10.3 Mobile Data Computer Room Solution
- Pain Points: Weak infrastructure at edge sites, rapid deployment demand, high integration, constant temperature & humidity, data security, remote monitoring.
- Recommended Configuration: 20ft/40ft Standard / Military shielded container + precision air conditioners + UPS power supply + cabinet arrays + environmental monitoring + remote communication modules.
- Solution Advantages: ≥70dB shielding isolates complex electromagnetic interference at edge sites to stabilize data equipment operation; precision air conditioners maintain 18–28℃ constant temperature & humidity with ±0.5℃ accuracy; UPS provides power backup during outages; remote monitoring tracks equipment status with automatic abnormality alarms; factory prefabricated, commissionable within 7 days on-site.
- Application Scenarios: Edge computing nodes, mobile data centers, disaster recovery rooms, small cabinet clusters, field data processing centers.
10.4 Confidential Office / R&D Center Solution
- Pain Points: Prevent information leakage, block external electromagnetic eavesdropping, comfortable office environment, integrated security monitoring.
- Recommended Configuration: 20ft Standard Mid-tier shielded container + shielded door + filter sockets + anti-static flooring + access control + HD cameras.
- Solution Advantages: ≥70dB shielding blocks electromagnetic signal leakage to prevent information theft via electromagnetic eavesdropping; filter sockets eliminate power interference for office equipment; access control + HD cameras track entry-exit logs to block unauthorized access; internal office-grade decoration delivers comfortable long-term working conditions.
- Application Scenarios: Government confidential departments, enterprise R&D centers, financial data processing centers, confidential meeting rooms, confidential archives.
11. Full Product Application Cases
11.1 Field Command Center Project for a Military Group
- Project Time: 2024
- Project Location: Northwest Field Training Ground
- Configuration Plan: 1 set of 40ft Military High-tier shielded container (KITOZER-SC40-H), matched with military shielded door, full-band filters, explosion-proof cameras, facial recognition access control and precision air conditioners.
- Project Outcome: Shielding effectiveness ≥90dB effectively blocks external radar and communication signal interference with zero internal confidential signal leakage; stable operation at -30℃~+50℃ field temperatures; facial recognition access control secures confidential zones; completed on-site deployment within 3 days to meet emergency command requirements, receiving high customer recognition.
11.2 EMC Testing Laboratory Project for an Electronic Technology Company
- Project Time: 2025
- Project Location: Shenzhen, Guangdong
- Configuration Plan: 2 sets of 20ft Standard Mid-tier shielded container (KITOZER-SC20-M), matched with high-performance shielding waveguide windows, signal filters, anti-static flooring and temperature & humidity sensors.
- Project Outcome: ≥70dB shielding meets EMI/EMC test accuracy standards, fully isolating external electromagnetic interference without internal test signal leakage; honeycomb waveguide windows guarantee ventilation and stable test equipment operation; anti-static flooring avoids electrostatic damage to precision testing instruments; stable temperature & humidity monitoring delivers accurate test data; project passed acceptance and runs reliably long-term.
11.3 Edge Computing Room Project for a Telecommunications Operator
- Project Time: 2025
- Project Location: Mountainous Guizhou
- Configuration Plan: 1 set of 20ft Standard Mid-tier shielded container (KITOZER-SC20-M), matched with precision air conditioners, UPS power supply, 2×42U cabinets and environmental monitoring system.
- Project Outcome: ≥70dB shielding isolates complex mountain electromagnetic interference to stabilize edge computing equipment; precision air conditioners maintain stable operating temperature of 22–25℃; UPS delivers 2-hour backup power during outages; remote monitoring tracks equipment status with automatic fault alarms; factory prefabricated, fully deployed within 5 days on-site to resolve insufficient edge computing capacity in mountainous areas rapidly.
11.4 Confidential Meeting Room Project for a Government Department
- Project Time: 2024
- Project Location: Beijing
- Configuration Plan: 1 set of 20ft Standard Mid-tier shielded container (KITOZER-SC20-M), matched with shielded door, filter sockets, anti-static flooring, fingerprint access control and HD cameras.
- Project Outcome: ≥70dB shielding blocks electromagnetic signal leakage to prevent confidential meeting content from being stolen via electromagnetic eavesdropping; fingerprint access control + HD cameras strictly manage personnel access and record entry-exit logs; interior office-standard decoration accommodates 15-person meetings with long-term stable operation, earning positive customer feedback.
12. Product Faults & Maintenance Guidelines
12.1 Common Faults & Troubleshooting Methods
12.1.1 Degraded Shielding Effectiveness
- Fault Phenomenon: Shielding effectiveness test fails, excessive electromagnetic leakage.
- Root Causes: ① Aged, deformed or foreign-object-contaminated shielded door spring reeds; ② Peeling or damaged conductive sealing strips at cabinet joints; ③ Blocked, deformed waveguide windows or poorly sealed frames; ④ Faulty grounding system with excessive grounding resistance.
- Troubleshooting: ① Clean foreign objects on door reeds, replace severely deformed reeds; ② Reapply conductive sealing strips at cabinet joints, replace damaged strips; ③ Clear blockages in waveguide honeycomb, correct deformation and re-seal frames; ④ Measure grounding resistance (normal ≤4Ω), inspect ground electrodes and wires, re-connect or replace as needed.
12.1.2 Ventilation System Failure
- Fault Phenomenon: Ventilator fails to start, insufficient air volume or abnormal noise.
- Root Causes: ① Power supply interruption or unstable voltage; ② Damaged ventilator motor or worn bearings; ③ Blocked waveguide honeycomb causing excessive ventilation resistance; ④ Faulty temperature sensor unable to trigger start-stop.
- Troubleshooting: ① Inspect power distribution cabinet power and repair supply faults; ② Check ventilator motor and bearings, replace damaged components; ③ Clear blockages in waveguide honeycomb; ④ Replace faulty temperature sensors.
12.1.3 Electrical System Failure
- Fault Phenomenon: Power distribution cabinet trips, lighting fails, equipment cannot power on.
- Root Causes: ① Short circuit or overload of wiring; ② Malfunctioning leakage protector; ③ Damaged surge protector; ④ Broken lighting fixtures or poor wiring contact.
- Troubleshooting: ① Cut power and inspect wiring to eliminate short circuit / overload faults; ② Replace faulty leakage protectors; ③ Replace damaged surge protectors; ④ Replace broken lighting fixtures and re-connect loose wiring.
12.1.4 Monitoring System Failure
- Fault Phenomenon: No sensor data, no camera image, unrecognizable access control.
- Root Causes: ① Power failure for sensors / cameras; ② Disconnected or loose network wiring; ③ Damaged sensors / cameras; ④ Faulty access control reader or controller.
- Troubleshooting: ① Restore power supply for wiring; ② Inspect network cables, re-connect or replace loose wiring; ③ Replace damaged sensors / cameras; ④ Repair or replace faulty access control readers and controllers.
12.2 Routine Maintenance Specifications
12.2.1 Daily Maintenance
- Inspect container exterior for deformation, damage and corrosion; clean surface dust and debris promptly.
- Check shielded door sealing and smooth opening/closing; clean foreign objects on reeds to ensure tight sealing.
- Review monitoring data to confirm normal temperature, humidity, smoke and water immersion parameters, clear camera image.
- Check power distribution cabinet indicators and display panels for abnormal alarms, confirm normal electrical operation.
12.2.2 Weekly Maintenance
- Clear dust and debris from waveguide honeycomb to avoid blockage; inspect tight frame sealing.
- Check ventilator operation for abnormal noise and vibration; clean internal dust and fasten loose screws.
- Test grounding system and measure grounding resistance to ensure ≤4Ω; confirm tight grounding wire connections.
- Inspect anti-static flooring for looseness or damage; wipe surface dust to preserve anti-static performance.
12.2.3 Monthly Maintenance
- Inspect shielded door reeds and conductive sealing strips; replace aged / damaged components and apply dedicated conductive lubricant.
- Clean internal dust from filters and power distribution cabinets; fasten wiring terminals to prevent short circuits from loose connections.
- Calibrate temperature, humidity and pressure sensors to guarantee accurate monitoring data; replace faulty sensors.
- Test full access control and alarm system functions to ensure fast recognition and timely alarms.
12.2.4 Annual Maintenance
- Conduct full third-party shielding effectiveness testing; troubleshoot and repair non-compliant equipment to meet standards.
- Complete inspection of all shielding components (cabinet, shielded door, waveguide window); repair or replace severely corroded / deformed parts.
- Replace ventilator bearings and sealing parts, perform motor maintenance to extend service life.
- Inspect emergency systems, replace expired fire extinguishers and test emergency lighting & escape indicators for normal function.
12.3 Maintenance Precautions
- All maintenance work must be performed by professional technicians with power cut-off to avoid electric shock and equipment damage.
- Do not disassemble shielding components, filters or grounding systems without authorization, as this will compromise shielding effectiveness.
- Avoid sharp tools during maintenance to prevent scratches on shielding layers and sealing components which cause electromagnetic leakage.
- Record all maintenance data to build maintenance files for convenient future fault diagnosis and servicing reference.
13. Factory Strength & After-sales Service
13.1 Factory Strength
- Production Scale: KITOZER owns a 15,000㎡ modern production base equipped with CNC cutting machines, laser welders, precision bending machines and shielding effectiveness testing equipment, with annual output of 500 shielded containers to fulfill large-batch orders.
- R&D Capability: A 20-person professional R&D team with core engineers holding over 10 years of electromagnetic shielding industry experience. The brand independently develops full-series shielding products, holding 15 utility model patents and 5 invention patents, with domestically leading technology matching international advanced standards.
- Quality Control: Full-process quality management system covering raw material procurement, production processing, assembly commissioning and factory inspection. All raw materials are sourced from reputable domestic brands and pass incoming testing; full monitoring of production processes with 100% inspection for key processes; every unit undergoes full testing of shielding effectiveness, electrical performance and security functions before delivery to guarantee 100% qualified products.
- Production Cycle: 7–15 days for standard basic / mid-tier models; 20–30 days for military and customized models for efficient delivery aligned with project timelines.
13.2 After-sales Service
- Warranty Commitment: 3-year free warranty for all full-series products; core shielding components (cabinet, shielded door, waveguide window) carry a 5-year warranty. Free repair and replacement of non-artificial damaged parts during warranty period, with lifetime maintenance support.
- Installation & Commissioning: Free on-site installation and commissioning with professional technicians to complete deployment within 3 days and ensure normal equipment operation.
- Technical Training: Free customer training covering product principles, operation procedures, routine maintenance and fault troubleshooting to enable independent operation and maintenance by on-site staff.
- 24-Hour Technical Support: 24-hour service hotline and online customer service with professional technical engineers on standby. Solutions provided within 1 hour; on-site maintenance within 4 hours for domestic urgent faults to resolve customer issues rapidly.
- Spare Parts Support: Complete spare parts warehouse with full stock of common accessories. Free replacement during warranty period, discounted supply post-warranty to eliminate maintenance worries.
- Regular Follow-up Visits: Quarterly customer visits to track equipment operation status, provide maintenance suggestions and proactively identify potential faults for long-term stable equipment performance.
14. Conclusion
As core equipment in the electromagnetic shielding sector, KITOZER shielded containers deliver four core strengths: high shielding effectiveness, full-scenario adaptability, rapid deployment and military-grade quality. They fully address electromagnetic shielding demands across national defense, electronic testing, data computer rooms, confidential offices and special protection industries. The full product lineup covers low, medium and high tiers with support for deep customization and OEM/ODM processing, balancing standardized mass production and personalized requirements to deliver one-stop electromagnetic shielding solutions for customers.
Moving forward, KITOZER will continue to deepen R&D of electromagnetic shielding technology, optimize product performance and expand application scenarios. We will supply higher-quality products and comprehensive after-sales services to help customers across all industries build secure, stable and efficient electromagnetic protection spaces, safeguarding national defense security, information security and industrial development.
15. SEO Optimization System
15.1 Core Search Keywords
- Primary Core Keywords: Shielded Container, Electromagnetic Shielded Container, KITOZER Shielded Container
- High-conversion Long-tail Keywords: Military-grade Shielded Container, Electromagnetic Testing Shielded Container, Mobile Shielded Data Room, Confidential Office Shielded Container, 20ft/40ft Shielded Container
- Industry Traffic Keywords: Electromagnetic Shielding Equipment, Industrial Special Container, Modular Shielded Shelter, EMC Testing Shielded Chamber, Confidential Electromagnetic Protection Equipment
- Brand-exclusive Keywords: KITOZER Electromagnetic Shielding, KITOZER Shielded Shelter
- Drop-down / Related Search Keywords: Shielded Container Price, Shielded Container Manufacturer, Custom Shielded Container, Shielded Container Shielding Effectiveness, Shielded Container Application Scenarios
15.2 SEO Optimization Tag System
15.2.1 Core Page Optimization Tags
- Page Title: KITOZER Shielded Container Solution – Military-grade Electromagnetic Shielding – Industrial Special Protective Equipment
- Page Subtitle: Professional R&D & Production of Electromagnetic Shielded Containers, Military Quality, Full-scenario Adaptability, Rapid Deployment
15.2.2 Title Tag
- Title: KITOZER Shielded Container | Military-grade Electromagnetic Shielding | Custom Industrial Special Container Manufacturer
15.2.3 Meta Keywords
- Meta Keywords: Shielded Container, Electromagnetic Shielded Container, KITOZER Shielded Container, Military Shielded Container, Industrial Special Container, Shielded Shelter, EMC Testing Shielded Chamber
15.2.4 Meta Description
- Meta Description: KITOZER shielded container is professional industrial special protective equipment with military-grade shielding effectiveness ≥70dB, supporting standard 20ft/40ft sizes and customization. Suitable for national defense, electronic testing, data computer rooms and confidential offices, factory prefabricated for rapid deployment, reliable quality and worry-free after-sales service.
15.2.5 H1 Tag
- H1: KITOZER Shielded Container Solution
15.2.6 H2 Tags
- H2: System Overview, System Composition, System Classification, System Schematic Diagram, System Configuration List, Product Technical Specifications, Product Application Scope, Product Advantages, Bid-winning Tender Parameters, Product Solution Packages, Application Cases, Product Faults & Maintenance Guidelines, Factory Strength & After-sales Service, Conclusion
15.2.7 Internal Link Optimization Tags
- Core Anchor Text: Shielded Container, Electromagnetic Shielded Container, KITOZER Shielded Container
- Long-tail Anchor Text: Military-grade Shielded Container, Mobile Shielded Data Room, EMC Testing Shielded Chamber, Modular Shielded Shelter
- Associated Anchor Text: Electromagnetic Shielding Equipment, Industrial Special Container, Confidential Protection Equipment, Precision Testing Equipment
这篇文章的语言风格可以更正式一些吗?
你可以润色一下这篇文章吗?
你能帮我翻译其他类型的文章吗?