The KITOZER hinged RF shielded door is a complete steel door assembly engineered for shielded rooms and Faraday enclosures. The door leaf and frame are continuously welded steel shells, and the mating perimeter uses beryllium copper fingerstock gaskets compressed by multiple cam-action hinges or magnetic seals. A gasket monitoring contact alerts the control system if the door is not fully closed, preserving the integrity of the shielded environment during sensitive tests.

The door is the most stressed seam in any shielded room because it opens and closes every day. A weak door gasket slowly degrades the room shielding as fingers wear, and a door left slightly open invalidates the entire test. The KITOZER door addresses both: fingerstock rated for hundreds of thousands of cycles keeps the seal for years, and the monitoring switch prevents a forgotten open door from ruining a measurement.

Technical Specifications

Shielding effectiveness greater than 100 dB from 10 MHz to 1 GHz and greater than 80 dB to 10 GHz. Door leaf 2 mm steel, frame 3 mm steel. Fingerstock gasket rated beyond 500,000 cycles. Cam latch with adjustable compression. Optional gasket continuity monitoring switch. Standard opening 900 mm by 2100 mm, custom sizes available. Surface painted or galvanized.

The cam latch pulls the door evenly against the fingerstock, ensuring uniform compression around the full perimeter rather than just at the latch point. The hinges carry the door weight without sagging, and the adjustable latch lets installers compensate for frame settlement. The monitoring switch closes an alarm circuit that the room controller reads, so a door ajar event is logged and annunciated.

Applications

Used as personnel access to EMC test chambers, shielded server rooms, TEMPEST secure rooms, MRI suites, and RF research labs. The door must be the highest-performance seam in the enclosure because it is opened and closed repeatedly, and the fingerstock design is built for that duty.

A test chamber needs a door that holds its shielding after thousands of openings. A TEMPEST room needs the door as part of a certified secure envelope. An MRI suite needs a door that patients can pass through safely. In each, the door is specified as a complete assembly rather than built on site, which guarantees the gasket and latch work together. For multi-door rooms, each door is wired to the same monitoring loop so the room controller sees every entrance. Heavy duty hinges are available for high traffic doors that open dozens of times a day. For laboratories that run tests around the clock, the door monitoring can be tied to the acquisition system so a door opening pauses the run and logs the event, which prevents invalid measurements from slipping through into a report.

Advantages and Features

The cam latch ensures uniform gasket compression around the full perimeter, avoiding the weak corners of simple swing doors. The fingerstock survives hundreds of thousands of cycles without replacement. The optional monitoring switch integrates with the room alarm system, and the welded construction eliminates leakage through the door shell itself.

Because the door ships as a preassembled unit, on-site welding and gasket fitting are eliminated, which shortens installation and removes the variables that cause field shielding defects. The leaf can be insulated for climate control, and the handle set can be matched to the building hardware specification. For cleanroom installations, the door face is flush and smooth so it wipes down without crevices that collect dust. The threshold can be specified with a ramp for wheelchair or equipment access without breaking the shield continuity.

Installation and Maintenance

Set the door frame plumb and weld or bolt it to the room shield with a continuous bond. Adjust the cam latch so the gasket compresses 20 percent to 30 percent. Inspect fingerstock quarterly for bent fingers and clean with contact cleaner. Lubricate hinges per schedule and verify the monitoring switch closes the alarm circuit.

After install, run a shielding verification measurement around the door perimeter and record it as the baseline. Re-measure annually or after any door adjustment. Replace fingerstock sections where fingers are bent or missing, and keep a spare strip on site. The cam latch is adjustable for life, so settling can be compensated without replacing hardware. For high-security rooms, the door can be fitted with an electronic interlock that locks the room alarm when the door opens, preventing unauthorized access during a secure test.

Price

From $1,280 per door. Contact plus 86 13922289957 for room door package. Monitoring switch and interlock options available.