Table of Contents
Toggle1. System Overview
The KITOZER shielded glass system is a dedicated transparent shielding solution for protection against Electromagnetic Interference (EMI) and Radio Frequency Interference (RFI). By embedding highly conductive metal wire mesh in glass interlayers or coating nano conductive films, it achieves efficient attenuation of electromagnetic signals while balancing visible light transmittance. Its core application scenarios include preventing information leakage, resisting electromagnetic interference, and blocking infrared peeping.
Compliant with the military standard GJB2713-96 and the electromagnetic compatibility standard GB/T17626.3, the system is applicable to shielded rooms, confidential computer rooms, medical MRI suites, military shelters and other venues. It delivers shielding effectiveness ranging from 20–80dB (30MHz–1GHz) with visible light transmittance of 30%–85%. Custom sizes and composite functions (explosion-proof, anti-fog heating, anti-glare, etc.) are available.
2. System Composition
- Core Components: Main shielded glass (wire mesh type / coated type / composite film-mesh type), shielding frame (aluminum alloy / stainless steel conductive frame), conductive sealing strips, copper foil edging strips, grounding terminals, shielding auxiliary materials (conductive gaskets, electromagnetic shielding tapes, insulating gaskets).
- Functional Optional Components: Heating modules (anti-fog), Anti-Reflection (AR) coatings, PVB explosion-proof interlayers, Low-E coatings, shielded grounding cables.
- Installation Components: Fixing hardware, expansion bolts, conductive connecting plates, insulating sleeves, neutral silicone conductive sealant.

Shielded Glass Sample
3. System Classification
3.1 Classification by Shielding Process
- Wire Mesh Shielded Glass (Mainstream) Double/multi-layer glass with embedded copper/stainless steel wire mesh, composited under high temperature and pressure. Shielding effectiveness: 40–80dB; light transmittance: 40%–70%. Suitable for medium and high shielding requirement scenarios.
- ITO Coated Shielded Glass Glass surface coated with nano indium tin oxide conductive film. Light transmittance ≥80%, shielding effectiveness 20–40dB. Ideal for high-transmittance, low-shielding applications.
- Composite Film-Mesh Shielded Glass Dual-layer shielding structure combining wire mesh and conductive film. Shielding effectiveness 60–80dB, light transmittance 45%–60%. Designed for high-end scenarios such as military industry and confidential command centers.
3.2 Classification by Shielding Effectiveness

Shielded Room Construction Drawing
- Low-Shield Grade (L Class): Shielding effectiveness 20–40dB (30MHz–1GHz), light transmittance ≥75%. For ordinary computer rooms and office partitions.
- Medium-Shield Grade (M Class): Shielding effectiveness 45–65dB (30MHz–1GHz), light transmittance 50%–70%. For standard shielded rooms, medical observation windows and equipment cabinets.
- High-Shield Grade (H Class): Shielding effectiveness 70–80dB (30MHz–1GHz), light transmittance 35%–50%. For military command centers, confidential meeting rooms and radar stations.
3.3 Classification by Structural Functions
- Ordinary single-layer shielded glass: Basic shielding function, thickness 4–12mm, for standard windows.
- Laminated explosion-proof shielded glass: PVB interlayer prevents glass splashing upon breakage, thickness 12–24mm, for confidential premises and military shelters.
- Heated shielded glass: Integrated conductive heating layer to eliminate fog and frost, for outdoor low-temperature environments such as base station monitoring windows.
- Extra-large size shielded glass: Maximum dimension 3000mm×1100mm, for large shielded rooms and command center viewing windows.
4. System Working Principle
External electromagnetic wave → Shielded glass (metal wire mesh / conductive film layer attenuates over 99.9% of signals) → Conductive sealing strips (block gap leakage) → Shielding frame (guides interfering signals to ground) → Grounding terminals (connect to earth / shielding ground grid) → Internal space (free of electromagnetic interference, information secured)
Notes:
- Wire mesh type: 5-layer composite structure: Glass + Metal Wire Mesh + Glass
- Coated type: 3-layer structure: Glass + Conductive Film + Protective Layer
- Copper foil edging around glass perimeter ensures continuous grounding of shielding layers

Shielded Glass Production Workshop
5. System Configuration List (Low / Medium / High Grades)
5.1 Low-Grade Package (L Class, 20–40dB, Light Transmittance ≥75%)
è¡¨æ ¼
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Coated Shielded Glass (L1) | KITOZER-PG-L1 | Thickness: 5mm; Size:1200×800mm; SE:20–30dB (30MHz–1GHz); Light transmittance ≥80%; Sheet resistance:5–14Ω/□; Tempered | 1 | Piece | KITOZER | Ordinary computer rooms, office partitions |
| 2 | Aluminum Alloy Shield Frame | KITOZER-Frame-L | Material:6063-T6 Al alloy; Wall thickness:1.2mm; Conductive oxidation finish; Fits 1200×800mm glass | 1 | Set | KITOZER | Includes frame, corner fittings, fasteners |
| 3 | Conductive Sealing Strip | KITOZER-Seal-L | Conductive rubber; Spec:10×5mm; Resistance ≤0.5Ω/cm; Temp range:-40℃~+60℃ | 10 | Meter | KITOZER | Seal between glass and frame |
| 4 | Copper Foil Edging Tape | KITOZER-Cu-L | 15mm width, 0.05mm thickness, conductive adhesive; Wrap glass edge shielding layer | 5 | Meter | KITOZER | Continuously connect shielding layers around glass |
| 5 | Grounding Terminal | KITOZER-Gnd-L | Brass, M4 screw; For frame grounding | 4 | Piece | KITOZER | Frame earthing fittings |
| 6 | Shield Installation Auxiliary Kit | KITOZER-Acc-L | Expansion bolts, insulating gaskets, neutral sealant | 1 | Set | KITOZER | Full installation accessories |
5.2 Medium-Grade Package (M Class, 45–65dB, Light Transmittance 50%–70%)
è¡¨æ ¼
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Wire Mesh Shielded Glass (M1) | KITOZER-PG-M1 | Thickness:10mm; Size:1500×1000mm; 130 mesh / 0.027mm copper mesh; SE:55–65dB (30MHz–1.5GHz); Light transmittance:60%–70%; Tempered laminated | 1 | Piece | KITOZER | Standard shielded rooms, medical observation windows |
| 2 | Stainless Steel Shield Frame | KITOZER-Frame-M | 304 stainless steel; Wall thickness:1.5mm; Polished conductive finish; Fits 1500×1000mm glass | 1 | Set | KITOZER | Frame, conductive connecting plates, fasteners included |
| 3 | High-Conductivity Sealing Strip | KITOZER-Seal-M | Silver powder filled conductive silicone; Spec:12×6mm; Resistance ≤0.1Ω/cm; Temp:-45℃~+80℃; Waterproof & dustproof | 12 | Meter | KITOZER | Gap shielding & sealing |
| 4 | Thickened Copper Foil Edging Tape | KITOZER-Cu-M | 20mm width, 0.1mm thickness, high-temp conductive adhesive, anti-oxidation treatment | 6 | Meter | KITOZER | Continuous shielding layer connection |
| 5 | Special Grounding Terminal | KITOZER-Gnd-M | Pure copper, M5 screw with anti-loose washers; Matches shielding ground grid | 4 | Piece | KITOZER | Reliable earthing |
| 6 | Explosion-Proof Lamination Auxiliary Kit | KITOZER-Acc-M | 0.76mm PVB film, conductive connecting plates, insulating sleeves | 1 | Set | KITOZER | Explosion resistance enhancement & installation parts |
5.3 High-Grade Package (H Class, 70–80dB, Light Transmittance 35%–50%)
è¡¨æ ¼
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Composite Film-Mesh Shielded Glass (H1) | KITOZER-PG-H1 | Thickness:18mm; Size:1800×1200mm; 250 mesh / 0.03mm stainless steel mesh + double-sided ITO coating; SE:70–80dB (30MHz–1GHz); Light transmittance:40%–50%; Explosion-proof lamination + AR coating | 1 | Piece | KITOZER | Military command centers, confidential meeting rooms |
| 2 | High-Strength Shield Frame | KITOZER-Frame-H | 6061-T6 aluminum alloy with hard conductive anodizing; Wall thickness:2.0mm, reinforced rib design; Fits 1800×1200mm glass | 1 | Set | KITOZER | Frame, shielding gaskets, heavy-duty fasteners included |
| 3 | Ultra-High Conductivity Sealing Strip | KITOZER-Seal-H | Silver-plated copper powder filled conductive elastomer; Spec:15×8mm; Resistance ≤0.05Ω/cm; Temp:-50℃~+90℃; Salt spray & mildew resistant | 15 | Meter | KITOZER | Military-grade gap shielding |
| 4 | Wide Pure Copper Edging Tape | KITOZER-Cu-H | 25mm width, 0.15mm thickness, vacuum silver plating, anti-corrosion & high conductivity | 8 | Meter | KITOZER | High-end shielding layer connection |
| 5 | Military-Grade Grounding Terminal | KITOZER-Gnd-H | Silver-plated pure copper, M6 screw with shielding cover; Matches dedicated shielding ground grid | 4 | Piece | KITOZER | Low-impedance earthing |
| 6 | Multi-Function Composite Auxiliary Kit | KITOZER-Acc-H | Optional heating module, AR anti-reflection film, Low-E coating, high-strength sealant | 1 | Set | KITOZER | Function enhancement, military-grade installation accessories |
6. Full Product Technical Specifications
6.1 Coated Shielded Glass (L1)

On-site Glass Installation
- Thickness:5mm (customizable 3–8mm)
- Max size:1500×1000mm (customizable)
- Shielding Effectiveness:20–30dB (30MHz–1GHz)
- Visible light transmittance ≥80% (380–760nm)
- Sheet resistance:5–14Ω/□
- Structure: Float glass + ITO conductive film + tempering treatment
- Operating temperature:-40℃~+60℃
- Compliance standard: GB/T17626.3
6.2 Wire Mesh Shielded Glass (M1)
- Thickness:10mm (customizable 8–16mm)
- Max size:2000×1000mm (customizable)
- Mesh spec:130 mesh / 0.027mm copper mesh (100–250 mesh customizable)
- Shielding Effectiveness:55–65dB (30MHz–1.5GHz)
- Light transmittance:60%–70%
- Structure: Double float glass + PVB film + copper wire mesh, high temperature & pressure lamination
- Operating temperature:-45℃~+80℃
- Impact resistance: Tempered, no splashing upon breakage
- Compliance standard: GJB2713-96

Glass Cross-Section Exploded Drawing
- Thickness:18mm (customizable 16–24mm)
- Max size:3000×1100mm (customizable)
- Structure: 250 mesh / 0.03mm stainless steel mesh + double-sided ITO coating + double PVB explosion-proof interlayers
- Shielding Effectiveness:70–80dB (30MHz–1GHz)
- Light transmittance:40%–50%
- Sheet resistance ≤3Ω/□
- Optional functions: AR anti-reflection, Low-E heat insulation, explosion-proof, UV blocking
- Operating temperature:-50℃~+90℃
- Vibration resistance: No loosening or cracking under 10–500Hz vibration
- Compliance standards: GJB2713-96, military EMC standards
6.4 Shielding Frames (L/M/H Grades)
- Material: L Grade:6063-T6 Al alloy; M Grade:304 stainless steel; H Grade:6061-T6 Al alloy
- Wall thickness: L Grade:1.2mm; M Grade:1.5mm; H Grade:2.0mm
- Surface finish: L Grade: conductive oxidation; M Grade: polished conductive treatment; H Grade: hard anodizing + conductive coating
- Matching size: Corresponding glass dimensions, tolerance ≤±1mm
6.5 Conductive Sealing Strips (L/M/H Grades)

On-site Frame Installation
- Material: L Grade: conductive rubber; M Grade: silver powder conductive silicone; H Grade: silver-plated copper powder conductive elastomer
- Spec dimensions: L Grade:10×5mm; M Grade:12×6mm; H Grade:15×8mm
- Linear resistance: L Grade ≤0.5Ω/cm; M Grade ≤0.1Ω/cm; H Grade ≤0.05Ω/cm
- Temperature range: L Grade -40℃~+60℃; M Grade -45℃~+80℃; H Grade -50℃~+90℃
- Performance: Waterproof, dustproof, anti-aging, high elasticity
7. Product Application Scope
7.1 Coated Shielded Glass (L Grade)
- Ordinary computer rooms, server cabinet observation windows
- Office & meeting room partitions (prevent information leakage)
- Display windows of civil electronic equipment (printers, plotters, etc.)
- Low-voltage power distribution rooms, monitoring room observation windows
7.2 Wire Mesh Shielded Glass (M Grade)

Command Center Application Scene
- Standard electromagnetic shielded rooms & shielded machine room viewing windows
- Medical MRI & CT suite observation windows (block RF interference)
- Military shelters, communication vehicle viewing windows
- Banking & securities trading rooms (anti-electromagnetic eavesdropping)
- High-voltage substations, base station control room observation windows
7.3 Composite Film-Mesh Shielded Glass (H Grade)
- Military command centers, radar stations, confidential meeting rooms
- Government confidential computer rooms, diplomatic office areas
- High-end data centers & cloud computing center shielding windows
- Aerospace laboratories, EMC testing chambers
- Border military outpost observation windows
7.4 Shielding Auxiliary Materials & Fittings
- Full supporting accessories for shielded glass installation to guarantee continuous shielding layer grounding
- Gap shielding & sealing for shielded rooms and shielding cabinets
- EMI grounding system connection accessories
8. Product Advantages
8.1 Core Functional Advantages

Building Curtain Wall Application
- Full-range high shielding performance: 20–80dB full coverage, military grade up to 80dB, attenuating over 99.99% electromagnetic signals to block information leakage, EMI and infrared surveillance.
- Balanced high light transmittance: Coated type ≥80%, wire mesh type 50%–70%; no optical distortion without obstructing observation.
- Explosion-proof safety: Laminated structure prevents glass splashing when broken; tempered treatment delivers impact resistance, compliant with safety glass standards for confidential and military sites.
- Wide environmental adaptability: Operating temperature -50℃~+90℃, dustproof, salt-spray resistant and mildew-proof, suitable for harsh coastal and low-temperature outdoor environments.
8.2 Customization Advantages
- Size customization: Max dimension 3000×1100mm, non-standard & special shapes (round, curved) available.
- Function customization: Integrated heating (anti-fog), AR anti-reflection, Low-E thermal insulation, anti-glare, bulletproof and other composite functions.
- Process customization: Adjustable wire mesh count (100–250 mesh), film thickness, frame material & color as required.
8.3 Production & Service Advantages
- Self-developed full-process production: KITOZER factory owns Class 100 clean rooms and complete production equipment (CNC engravers, dispensers, laminators, high-pressure composite machines) for closed-loop manufacturing with stable quality control.
- Confidential customization service: Confidential production for military and classified projects with signed non-disclosure agreements and full confidential management.
- In-stock supply: Regular sizes (1200×800, 1500×1000) kept in inventory for fast delivery.
- OEM/ODM processing: Custom manufacturing per customer drawings & requirements, supporting private brand labeling.
- Authoritative standard compliance: Full product line meets military standard GJB2713-96 and national EMC standards, leading industry indicators for shielding effectiveness, transmittance and temperature resistance.

Large Glass Curtain Wall
9. Bid Control Parameters (★ = Core Bid Control Item)
9.1 Coated Shielded Glass (L1)
- ★ Shielding Effectiveness: 20–30dB (30MHz–1GHz)
- ★ Light transmittance ≥80%
- ★ Sheet resistance:5–14Ω/□
- Thickness:5mm (±0.5mm)
- Standard size:1200×800mm (customizable)
- Operating temperature:-40℃~+60℃
- Compliance standard: GB/T17626.3
9.2 Wire Mesh Shielded Glass (M1)
- ★ Shielding Effectiveness:55–65dB (30MHz–1.5GHz)
- ★ Light transmittance:60%–70%
- ★ Mesh spec:130 mesh / 0.027mm copper mesh
- Thickness:10mm (±1.0mm)
- Standard size:1500×1000mm (customizable)
- Impact resistance: Tempered, no splashing upon breakage
- Compliance standard: GJB2713-96
9.3 Composite Film-Mesh Shielded Glass (H1)
- ★ Shielding Effectiveness:70–80dB (30MHz–1GHz)
- ★ Light transmittance:40%–50%
- ★ Structure: 250 mesh stainless steel mesh + double-sided ITO coating + explosion-proof interlayer
- Thickness:18mm (±1.5mm)
- Standard size:1800×1200mm (max customizable 3000×1100mm)
- Optional functions: Anti-reflection, Low-E thermal insulation, explosion-proof, UV blocking
- Operating temperature:-50℃~+90℃
- Compliance standards: GJB2713-96, military EMC standards
9.4 Shielding Frames (L/M/H)
- ★ Material: L Grade:6063-T6 Al alloy; M Grade:304 stainless steel; H Grade:6061-T6 Al alloy
- ★ Wall thickness: L Grade:1.2mm; M Grade:1.5mm; H Grade:2.0mm
- Surface finish: Conductive oxidation / polished conductive / hard conductive anodizing
- Matching dimension tolerance ≤±1mm
9.5 Conductive Sealing Strips (L/M/H)
- ★ Material: Conductive rubber / silver powder conductive silicone / silver-plated copper powder conductive elastomer
- ★ Linear resistance: L Grade ≤0.5Ω/cm; M Grade ≤0.1Ω/cm; H Grade ≤0.05Ω/cm
- Standard dimensions:10×5 / 12×6 / 15×8mm
- Temperature range: -40℃~+60℃ / -45℃~+80℃ / -50℃~+90℃
10. Targeted Solution Packages
10.1 Ordinary Computer Room Shielding Solution (L Low Grade)
- Demand: Prevent EMI & information leakage for general computer rooms, high light transmittance, cost-effective.
- Configuration: KITOZER-PG-L1 coated shielded glass + aluminum alloy shielding frame + conductive sealing strips + copper foil edging + grounding terminals.
- Outcome: 20–30dB shielding effectiveness, ≥80% light transmittance. Blocks external electromagnetic interference and stops internal data signal leakage, simple installation with high cost performance.
10.2 Standard Shielded Room Solution (M Medium Grade)
- Demand: Standard shielded rooms, medical MRI suites, equipment cabinets; medium shielding performance with explosion-proof safety.
- Configuration: KITOZER-PG-M1 wire mesh shielded glass + stainless steel shielding frame + high-conductivity sealing strips + thickened copper foil edging + dedicated grounding terminals + explosion-proof lamination auxiliary kit.
- Outcome: 55–65dB shielding effectiveness, 60%–70% light transmittance. Explosion-proof anti-splash design fully isolates RF interference, ensures normal operation of medical & precision equipment, meets industry standards.
10.3 Military & Confidential Premise Solution (H High Grade)
- Demand: Military command centers, confidential meeting rooms, high-end data centers; ultra-high shielding performance, multi-functional integration, classified security production.
- Configuration: KITOZER-PG-H1 composite film-mesh shielded glass + high-strength shielding frame + ultra-high conductivity sealing strips + wide pure copper edging + military-grade grounding terminals + multi-function auxiliary kit (heating / AR / Low-E optional).
- Outcome:70–80dB shielding effectiveness, 40%–50% light transmittance. Integrated anti-reflection, thermal insulation and explosion-proof functions; military confidential production blocks electromagnetic eavesdropping and infrared imaging to fully secure classified information.
10.4 Outdoor Low-Temperature Environment Custom Solution (Custom H Grade)
- Demand: Outdoor base stations, border outpost observation windows; anti-fog, low-temperature resistance, high shielding performance.
- Configuration: Heated KITOZER-PG-H1 shielded glass + high-strength shielding frame + ultra-high conductivity sealing strips + heating module + military-grade grounding terminals.
- Outcome:70–80dB shielding effectiveness, adjustable heating temperature (0–40℃) eliminates fog & frost; withstands -50℃~+90℃ temperature range for clear observation and stable shielding performance under harsh outdoor cold conditions.
11. Project Application Cases
11.1 Provincial Government Confidential Computer Room Project
- Requirement: Prevent information leakage & EMI for classified computer rooms, comply with national confidentiality standards.
- Configuration: KITOZER-PG-H1 composite film-mesh shielded glass (1800×1200mm) + high-strength shielding frame + ultra-high conductivity sealing strips.
- Result:75dB shielding effectiveness, 45% light transmittance, passed State Secrets Bureau inspection. Effectively blocks electromagnetic signal leakage to secure classified data, zero failure after 3 years of operation.
11.2 Grade-A Hospital MRI Suite Renovation Project
- Requirement: MRI observation window blocks 128MHz RF interference for clear imaging, explosion-proof safety.
- Configuration: KITOZER-PG-M1 wire mesh shielded glass (1500×1000mm) + stainless steel shielding frame + high-conductivity sealing strips.
- Result:60dB shielding effectiveness, 65% light transmittance. Fully isolates MRI RF interference for noise-free imaging, explosion-proof design passed medical equipment certification.
11.3 Military Command Center Construction Project
- Requirement: Large viewing window with ultra-high shielding, anti-infrared surveillance, multi-functional composite, military-grade standard.
- Configuration: Custom oversized KITOZER-PG-H1 composite film-mesh shielded glass (2500×1000mm) + high-strength shielding frame + multi-function auxiliary kit (AR + Low-E).
- Result:78dB shielding effectiveness, 42% light transmittance, anti-infrared imaging, thermal insulation and anti-reflection features. Passed military EMC testing to guarantee information security and clear viewing for command operations.
11.4 Communication Base Station Outdoor Monitoring Window Project
- Requirement: Outdoor monitoring window anti-fog, low-temperature resistant, anti-EMI, withstand -40℃ extreme cold.
- Configuration: Heated KITOZER-PG-H1 shielded glass (1200×800mm) + high-strength shielding frame + heating module.
- Result:70dB shielding effectiveness, stable 25℃ heating eliminates fog & frost at -40℃; clear monitoring footage with zero failure after 2 years of outdoor operation.
12. Common Faults & Maintenance Guidelines
12.1 Common Fault Troubleshooting
- Fault 1: Reduced shielding effectiveness (gap leakage)
- Root causes: Aging/fallen conductive sealing strips; oxidized/cracked copper foil edging; poor frame grounding.
- Solutions: Replace aged sealing strips; polish copper foil oxidation and re-wrap tightly; inspect grounding terminals for firm connection without rust.
- Fault 2: Water stains & bubbles inside glass interlayer
- Root causes: Poor sealing during installation letting moisture enter interlayer; sealant aging under high temperature & humidity.
- Solutions: Mild water stains can be removed via ventilation drying; severe bubbles require factory re-lamination; replace anti-aging sealing strips.
- Fault 3: Reduced light transmittance, foggy glass surface
- Root causes: Dust & oil accumulation; scratched/oxidized conductive coating.
- Solutions: Wipe surface with neutral detergent and soft cloth; minor coating scratches can be polished; severely scratched glass needs full replacement.
- Fault 4: Heated glass fails to heat / uneven heating
- Root causes: Loose/burnt heating module wiring; faulty temperature controller.
- Solutions: Inspect wiring and replace burnt modules; calibrate or replace temperature controller; return to factory for full inspection & repair.
12.2 Standard Maintenance Specifications
Monthly Routine Maintenance
- Surface cleaning: Wipe with neutral detergent and soft cotton cloth; avoid acidic/alkaline cleaners that corrode coatings & wire mesh.
- Seal inspection: Check sealing strips for aging, cracking or detachment and replace promptly; inspect copper foil edging for oxidation & warping, re-compress wrapping.
- Grounding inspection: Check grounding terminals & cables for rust and looseness; ensure grounding resistance ≤4Ω.
Quarterly Maintenance (Every 3 Months)
- Performance testing: Test shielding effectiveness with shielding tester to verify compliance with original grade; measure light transmittance to confirm no obvious degradation.
- Frame inspection: Check frame deformation & rust, tighten all fasteners to ensure tight contact between frame and glass.
- Environment inspection: Monitor ambient temperature & humidity (-50℃~+90℃, humidity ≤85% without condensation); avoid long-term high-temperature & high-humidity exposure.
Annual Full Maintenance (Once Per Year)
- Full performance testing: Deliver to factory or professional institution for complete testing (shielding effectiveness, light transmittance, sheet resistance, temperature resistance, etc.) with official test report issued.
- Aging part replacement: Replace sealing strips and copper foil edging after 3 years of service; fully inspect glass after 5 years, replace if necessary.
- Ground grid inspection: Check ground grid for corrosion & fracture to guarantee stable, leakage-free grounding.
13. Factory Strength & After-Sales Service
13.1 Factory Strength
- Production Scale: Factory located in Guangzhou, Guangdong, covering 4,600 m² total area, 2,100 m² production workshop including 1,400 m² Class 100 clean room; professional dedicated shielded glass production base.
- Production Equipment: Full imported automated production lines including ultra-thin glass engravers, RTV dispensers, optical laminators, special edge grinders and high-pressure composite machines for high-precision, stable mass production.
- R&D Capacity: R&D team with over 10 professional engineers, multiple shielded glass patents, proprietary core technologies for wire mesh embedding, ITO nano coating and composite lamination with continuous product iteration & upgrade.
- Quality Certifications: National High-Tech Enterprise, ISO9001 Quality System, ISO14001 Environmental System, military product quality certification; products comply with GJB2713-96, GB/T17626.3 and other standards.
- Production Capacity: 50 pieces daily output for standard sizes, 20 pieces daily for oversized/custom glass; over 1,000 pieces permanent inventory for fast delivery (3–7 days for standard orders, 7–15 days for custom orders).
13.2 After-Sales Service Commitments
- Warranty Policy: 3-year full product warranty from acceptance date; free repair & replacement of non-artificial damaged accessories within warranty period; 5-year warranty for core glass panels.
- Installation Service: Professional nationwide installation teams covering over 30 provinces & cities; free technical guidance, on-site installation & commissioning to meet shielding performance standards.
- Technical Support: 7×24-hour technical hotline for free consultation, scheme design and model selection; remote fault diagnosis with rapid response.
- Repair Service: Free repair within warranty; cost-price maintenance post-warranty with free round-trip shipping for remote mail-in repair; on-site troubleshooting within 24 hours for major failures.
- Lifelong Customization Service: Free technical upgrade & reconstruction for all clients; quarterly follow-up visits to monitor product operation and provide maintenance recommendations.
- Confidentiality Service: Sign non-disclosure agreements for military & classified projects, full confidential control over production, delivery and installation to protect client sensitive information.
14. Conclusion
As a core product in electromagnetic shielding protection, the KITOZER shielded glass system delivers five core strengths: full-range shielding effectiveness, high light transmittance, explosion-proof safety, flexible customization and military-grade quality. Widely deployed across government, military, medical, communication and data center industries, it provides efficient, reliable electromagnetic shielding solutions to resolve three core pain points: information leakage, electromagnetic interference and infrared surveillance.
Moving forward, KITOZER will continue to increase R&D investment, optimize manufacturing processes, upgrade product performance and quality, expand application scenarios, and deliver more professional, comprehensive electromagnetic shielding products and services to support national information security and electromagnetic protection development.
15. Search Keywords, SEO & Tags
15.1 Search Keywords
- Core Keywords: KITOZER shielded glass, electromagnetic shielding glass, shielded glass manufacturer, military shielded glass, confidential shielding glass
- Long-Tail Keywords: Computer room shielding glass, MRI suite shielding glass, command center shielding glass, explosion-proof shielding glass, heated shielding glass, high shielding effectiveness glass, anti-information-leakage glass, EMI protection glass
- Scenario Keywords: Confidential computer room shielding, medical shielding observation window, military shelter shielding, data center shielding, outdoor low-temperature shielding glass
15.2 SEO Optimization
Title Optimization: Place core keywords at the front, e.g. “KITOZER Shielded Glass – Electromagnetic Shielding Glass Manufacturer for Military & Confidential Computer Rooms”
15.3 Tags
- Product Tags: #KITOZER #ShieldedGlass #ElectromagneticShieldingGlass #MilitaryGlass #ConfidentialGlass
- Function Tags: #AntiInformationLeakage #AntiEMI #AntiInfraredSurveillance #ExplosionProofGlass #HighTransmittanceGlass
- Scenario Tags: #ComputerRoomShielding #MedicalShielding #MilitaryCommandCenter #DataCenter #OutdoorShielding