Table of Contents
Toggle1. System Introduction
The KITOZER shielded partial discharge (PD) chamber is an electromagnetic shielding facility specially designed for partial discharge detection of high-voltage electrical equipment. Built based on the Faraday cage principle as a fully metal-sealed cavity, it completely isolates external electromagnetic interference including spatial electromagnetic waves, power harmonics and ground noise, suppressing the test background noise to ≤1 pC to meet ultra-high-sensitivity pC-level PD testing requirements.
Complying strictly with national standards GB/T12190-2006 and GB/T51103-2015, the integrated system consists of shielding enclosure, filtering, insulation, grounding, safety control and other subsystems. It features four core characteristics: high shielding effectiveness, superior insulation isolation, ultra-low background noise and easy disassembly & relocation. Widely applied in power equipment manufacturing, research institutes and power grid operation & maintenance scenarios, it serves as core supporting equipment for PD tests of transformers, GIS, power cables, transformers and other high-voltage products.

Shielded Partial Discharge Chamber
2. System Composition
The KITOZER shielded PD chamber is composed of 10 core subsystems that work in coordination to guarantee shielding performance, insulation performance and test safety:
- Shielding Enclosure Subsystem: Hexahedral fully enclosed shielding structure including walls, top plates, bottom plates and shielding doors, made of galvanized steel or stainless steel sheets. Joints are sealed with conductive gaskets to form a continuous conductive shield body.
- Power Filter Subsystem: Special shielding filters for power inlet lines to suppress high-frequency grid interference and block conductive interference entering the shielding chamber via power lines.
- Insulation Isolation Subsystem: Insulated floor slabs, insulated supports and insulated connectors electrically isolate the shielding chamber from external ground and foundation, with insulation resistance ≥1000 MΩ.
- Independent Grounding Subsystem: Single-point grounding design with dedicated grounding electrodes and grounding main bars, grounding resistance ≤1 Ω to discharge induced charges on the shield body and avoid interference from ground potential difference.

Construction Drawing of Shielded PD Chamber
- Shielding Door Subsystem: Personnel doors and test piece doors (single/double leaf) equipped with beryllium bronze elastic sealing strips and door interlock devices. Power is cut off when doors open and restored when closed to ensure shielding performance and operation safety.
- Ventilation Waveguide Subsystem: Honeycomb waveguide windows or waveguide ventilators that balance ventilation and shielding performance to prevent electromagnetic wave leakage through air vents.
- Lighting & Monitoring Subsystem: Explosion-proof shielded lamps, indoor & outdoor monitoring cameras and intercom devices to realize indoor lighting, remote monitoring and two-way communication.
- Signal Interface Subsystem: Shielded signal connectors and wall-penetrating shield sleeves for test and control signal routing to avoid interference introduced during signal transmission.
- Safety Interlock Subsystem: Door control interlocks, emergency stop devices, high-voltage warning indicators and leakage protection form multi-layer safety protection against high-voltage electric shock and electromagnetic radiation risks.
- Auxiliary Subsystem: Indoor grounding busbars, cable trays, anti-static facilities and temperature & humidity regulators to stabilize the test environment and ensure reliable equipment operation.
3. System Classification
Classified from four dimensions: structural technology, shielding grade, application scenario and installation method to meet diverse budget and testing requirements.
3.1 Classification by Structural Technology
- Modular Standard Type: Assembled with 1.5–2 mm galvanized steel modules fixed by M8 bolts and sealed with conductive gaskets. Easy to disassemble, relocate and reuse with a short construction period (7–15 days). Shielding effectiveness: 60–80 dB, suitable for small & medium PD chambers (≤50 ㎡).
- Full Welded High-End Type: Fully welded with 2–3 mm galvanized steel sheets featuring continuous sealed welds, delivering high overall strength and excellent shielding tightness. Shielding effectiveness: 80–110 dB, background noise ≤0.5 pC, ideal for high-precision testing, large shielding chambers (≥50 ㎡) or fixed installation sites.
- Corrugated Economical Type: Assembled with corrugated galvanized steel sheets at low cost with fast construction. Shielding effectiveness: 40–60 dB, applicable to budget-limited conventional precision testing scenarios such as low-voltage electrical appliances and small transformers.

Workshop Production Site
3.2 Classification by Shielding Grade
- Basic Grade (60 dB): Shielding attenuation ≥60 dB in 10 kHz–1 GHz frequency band, background noise ≤2 pC, meeting conventional PD testing requirements for 10–35 kV equipment.
- Advanced Grade (80 dB): Shielding attenuation ≥80 dB in 10 kHz–3 GHz frequency band, background noise ≤1 pC, compatible with 110–220 kV equipment and UHF ultra-high frequency PD detection.
- Professional Grade (100 dB): Shielding attenuation ≥100 dB in 10 kHz–3 GHz frequency band, background noise ≤0.1 pC, used for 500 kV and above extra-high voltage equipment and high-precision experiments in research institutes.
3.3 Classification by Application Scenario
- Transformer-Dedicated PD Chamber: Oversized dimensions (≥8×6×4 m) with high load-bearing capacity (≥1000 kg/㎡), adapted for testing large oil-immersed and dry-type transformers.
- GIS/Switchgear-Dedicated PD Chamber: Elongated design with oversized test piece door (≥2.5×3 m) to accommodate full-section testing of high-voltage switchgear.
- Cable & Accessory-Dedicated PD Chamber: Long strip structure (≥15×4×3 m) capable of holding long-distance cables, equipped with dedicated cable fixing brackets.
- Instrument Transformer & Small Electrical Appliance-Dedicated PD Chamber: Miniaturized layout (≤5×4×3 m) with economical configuration for testing instrument transformers, insulators, low-voltage electrical appliances and other small components.
3.4 Classification by Installation Method

On-site Installation & Commissioning
- Floor-Standing Conventional Type: Installed directly on workshop floors without special foundations, compatible with most factory premises.
- Pit-Mounted Reinforced Insulation Type: 300–500 mm deep underground pit lined with insulation and shielding layers for enhanced insulation performance, suitable for testing requiring ultra-high insulation standards.
- Floor-Lightweight Type: Lightweight modular structure with optimized load-bearing capacity (≤600 kg/㎡), designed for installation on the second floor and above.
4. System Schematic Principles
4.1 Overall Shielding Principle
External electromagnetic interference (spatial electromagnetic waves, power interference, ground interference) → Shielding enclosure (steel Faraday cage) for reflection & absorption → Interference attenuation ≥60 dB → Pure electromagnetic environment formed inside the chamber → PD test equipment captures authentic discharge signals.
4.2 Electrical Connection Schematic
External power supply → Power filter → Indoor power distribution system → Lighting/monitoring/test equipment
Shield enclosure → Insulation isolation layer → Independent grounding electrode (≤1 Ω) → Earth
Test equipment → Shielded signal interface → External detection system
Shield door → Door interlock device → High-voltage control loop (power cut off when doors open, power restored when closed)

Shielded Electrical Cabinet
4.3 Shield Joint Sealing Schematic
Shield module (galvanized steel sheet) → Conductive gasket (beryllium bronze/conductive rubber) → Bolt fastening → Continuous conductive sealing → Zero electromagnetic wave leakage
5. Full System Configuration List (3 Tiers: Basic / Mid / High-End, KITOZER Brand)
5.1 Basic Tier List (60 dB Basic Grade, Economical Corrugated Plate)
表格
| No. | Product Name | Model Spec | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Corrugated Shield Enclosure | KITOZER-PB60-W | Size: 5m×4m×3m; Material:1.5mm corrugated galvanized steel; SE: ≥60 dB @10kHz–1GHz; Flatness ≤10mm/2m; Verticality ≤8mm | 1 | Set | KITOZER | Includes walls, top & bottom plates |
| 2 | Single-Leaf Personnel Shield Door | KITOZER-PD60-09 | Size:900mm×1900mm; Material:1.5mm galvanized steel; Seal: single-layer beryllium bronze strip; Mechanical interlock; Service life ≥5000 cycles | 1 | Leaf | KITOZER | Personnel access |
| 3 | Double-Leaf Test Piece Shield Door | KITOZER-PD60-18 | Size:1800mm×2200mm; Material:1.5mm galvanized steel; Seal: single-layer beryllium bronze strip; Mechanical interlock; Service life ≥5000 cycles | 1 | Leaf | KITOZER | Test piece access |
| 4 | Power Filter | KITOZER-FL60-380 | 380V/50Hz, 30A; Filter band:10kHz–1GHz; Insertion loss ≥60dB; 3-phase 4-wire wiring | 1 | Unit | KITOZER | Power inlet filtering |
| 5 | Insulated Floor Slab | KITOZER-IP60-54 | Size:5.5m×4.5m; 3mm PP board; Insulation resistance ≥500MΩ; Withstand voltage ≥5kV; Welded sealing | 1 | Set | KITOZER | Ground insulation isolation |
| 6 | Independent Grounding System | KITOZER-GR60-05 | 5 pcs 2.5m galvanized angle steel electrodes; 50mm² copper main bar; Ground resistance ≤1Ω; Single-point grounding | 1 | Set | KITOZER | Shield body grounding |
| 7 | Ventilation Waveguide Window | KITOZER-WG60-300 | 300×300mm; 8mm honeycomb aperture; SE≥60dB; Air flow ≥100m³/h; Aluminum alloy + copper plating | 2 | Pcs | KITOZER | Ventilation |
| 8 | Shielded Lighting Lamp | KITOZER-LT60-40 | 40W, 220V; SE≥60dB; IP54 explosion-proof; 6000K color temp | 4 | Pcs | KITOZER | Indoor illumination |
| 9 | Door Interlock Controller | KITOZER-IL60-01 | 220V control loop; Open-door power cut, close-door power restore; Acoustic & light fault alarm; Compatible with single/double leaf doors | 1 | Unit | KITOZER | Safety interlock control |
| 10 | Shielded Signal Interface | KITOZER-SP60-08 | BNC/SMA type, 8 channels; SE≥60dB; Wall-penetrating sealed; 50Ω impedance | 1 | Set | KITOZER | Test signal routing |
5.2 Mid Tier List (80 dB Advanced Grade, Standard Modular Assembly)
表格
| No. | Product Name | Model Spec | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Modular Shield Enclosure | KITOZER-PB80-P | Size:7m×5m×4m; 2mm cold-rolled galvanized steel; SE≥80dB @10kHz–3GHz; Flatness ≤8mm/2m; Verticality ≤5mm; Earthquake resistance ≥Grade 8 | 1 | Set | KITOZER | Walls, top/bottom plates & reinforcing beams included |
| 2 | Lockable Single-Leaf Personnel Shield Door | KITOZER-PD80-09 | 900×1900mm; 2mm galvanized steel; Double-layer beryllium bronze sealing strips; Electromagnetic interlock; Service life ≥10000 cycles; Detachable sealing strips | 1 | Leaf | KITOZER | Easy-replaceable sealing for personnel access |
| 3 | Rotatable Double-Leaf Test Piece Door | KITOZER-PD80-20 | 2000×3000mm; 2mm galvanized steel; Double-layer beryllium bronze strips; Electromagnetic + infrared interlock; Service life ≥10000 cycles; 50mm threshold | 1 | Leaf | KITOZER | Large test piece access |
| 4 | High-Performance Power Filter | KITOZER-FL80-380 | 380V/50Hz,50A; Filter band 10kHz–3GHz; Insertion loss ≥80dB; 3-phase 4-wire; Lightning protection | 1 | Unit | KITOZER | Deep power inlet filtering |
| 5 | Reinforced Insulated Floor Slab | KITOZER-IP80-75 | 7.5m×5.5m; 5mm PP board + insulated supports; Insulation resistance ≥1000MΩ; Withstand voltage ≥10kV; Welded + insulated glue edge sealing | 1 | Set | KITOZER | High insulation isolation |
| 6 | Precision Independent Grounding System | KITOZER-GR80-08 | 8 pcs 3m copper-clad steel electrodes;70mm² copper main bar; Ground resistance ≤0.5Ω; Single-point grounding + equipotential bonding | 1 | Set | KITOZER | Low-resistance anti-interference grounding |
| 7 | Waveguide Ventilator | KITOZER-WG80-500 | 500×500mm;6mm honeycomb aperture; SE≥80dB; Air flow ≥300m³/h; Stainless steel + nickel plating; Low-noise design | 2 | Unit | KITOZER | Forced ventilation with shielding |
| 8 | Explosion-Proof Shielded Lamp | KITOZER-LT80-50 | 50W,220V; SE≥80dB; IP65 explosion-proof; 5500K flicker-free lighting | 6 | Pcs | KITOZER | Uniform indoor illumination |
| 9 | Intelligent Door Interlock Controller | KITOZER-IL80-02 | 220V/380V control loop; Open-door power cut, close-door restore, high-voltage interlock; Acoustic-light + remote fault alarm; Multi-door linkage compatible | 1 | Unit | KITOZER | Intelligent safety interlock |
| 10 | High-Frequency Shielded Signal Interface | KITOZER-SP80-16 | BNC/SMA/N,16 channels; SE≥80dB; Wall-penetrating sealed; 50/75Ω impedance; Compatible up to 3GHz | 1 | Set | KITOZER | High-frequency test signal routing |
| 11 | Indoor Monitoring Camera | KITOZER-CM80-02 | 2MP resolution,120° viewing angle; IP65 shielding grade; Night vision; Remote transmission with shielded cables | 2 | Unit | KITOZER | Real-time indoor monitoring |
| 12 | Temperature & Humidity Sensor | KITOZER-TH80-01 | Temp: -20℃~60℃ (±0.5℃ accuracy); Humidity:0–100%RH (±3%RH accuracy); Shielded housing,485 communication | 1 | Unit | KITOZER | Ambient T&H monitoring |
5.3 High-End Tier List (100 dB Professional Grade, Full Welded Type)
表格
| No. | Product Name | Model Spec | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Full Welded Shield Enclosure | KITOZER-PB100-W | Size:10m×8m×5m; 3mm galvanized steel (2mm stainless steel inner wall); SE≥100dB @10kHz–3GHz; Flatness ≤5mm/2m; Verticality ≤3mm; Roof sag ≤5mm & floor depression ≤0.5mm within 5 years | 1 | Set | KITOZER | Fully welded sealed, with reinforcing keel & wave-absorbing layer |
| 2 | Premium Single-Leaf Personnel Shield Door | KITOZER-PD100-09 | 900×1900mm;3mm stainless steel; Triple vacuum heat-treated beryllium bronze sealing strips; Electromechanical dual locking interlock; Service life ≥20000 cycles; Detachable sealing strips | 1 | Leaf | KITOZER | High-sealing personnel door |
| 3 | Oversized Double-Leaf Test Piece Door | KITOZER-PD100-25 | 2500×3500mm;3mm stainless steel; Triple beryllium bronze strips; Electromagnetic + infrared + pressure triple interlock; Service life ≥20000 cycles; Threshold-free design | 1 | Leaf | KITOZER | Extra-large test piece access |
| 4 | Ultra-High Performance Power Filter | KITOZER-FL100-380 | 380V/50Hz,100A; Filter band 10kHz–3GHz; Insertion loss ≥100dB; 3-phase 5-wire; Lightning & surge protection | 1 | Unit | KITOZER | Ultra-deep power filtering |
| 5 | Ultra-High Strength Insulated Floor Slab | KITOZER-IP100-108 | 10.5m×8.5m;8mm PP board + ceramic insulated supports; Insulation resistance ≥2000MΩ; Withstand voltage ≥20kV; Triple sealing: welding + insulated glue + waterproof coating | 1 | Set | KITOZER | Ultra-high insulation isolation |
| 6 | Ultra-Low Resistance Independent Grounding System | KITOZER-GR100-12 | 12 pcs 3m pure copper electrodes;95mm² copper main bar; Ground resistance ≤0.1Ω; Single-point grounding + equipotential grid connection | 1 | Set | KITOZER | Ultra-low resistance grounding for maximum anti-interference |
| 7 | Custom Waveguide Ventilation System | KITOZER-WG100-800 | 800×800mm;4mm honeycomb aperture; SE≥100dB; Air flow ≥500m³/h; Silver-plated stainless steel; Low-noise & noise reduction | 2 | Set | KITOZER | High-efficiency ventilation with top-tier shielding |
| 8 | Premium Explosion-Proof Shielded Lamp | KITOZER-LT100-60 | 60W,220V; SE≥100dB; IP66 explosion-proof; 5000K anti-glare flicker-free lighting | 8 | Pcs | KITOZER | Premium uniform illumination |
| 9 | Industrial-Grade Door Interlock Controller | KITOZER-IL100-03 | 220V/380V control loop; Open-door power cut, close-door restore, high-voltage interlock, emergency stop; Acoustic-light + remote + APP fault alarm; Multi-door linkage & timing control | 1 | Unit | KITOZER | Industrial-grade safety interlock |
| 10 | Ultra-High Frequency Shielded Signal Interface | KITOZER-SP100-24 | BNC/SMA/N/2.92mm,24 channels; SE≥100dB; Wall-penetrating sealed;50Ω impedance; Compatible up to 6GHz | 1 | Set | KITOZER | Ultra-high frequency test signal routing |
| 11 | 4K HD Indoor Monitoring Camera | KITOZER-CM100-04 | 4MP resolution,150° viewing angle; IP67 shielding grade; Infrared & white light fill-in; 4K encrypted transmission with shielded cables | 4 | Unit | KITOZER | Full dead-angle-free HD monitoring |
| 12 | High-Precision T&H & Barometric Sensor | KITOZER-THP100-01 | Temp:-30℃~70℃ (±0.3℃); Humidity:0–100%RH (±2%RH); Barometric pressure:800–1100hPa (±0.5hPa); Shielded housing, Modbus communication | 2 | Unit | KITOZER | High-precision ambient monitoring |
| 13 | Wave-Absorbing Material | KITOZER-AB100-50 | Polyurethane carbon sponge,50mm thickness; Absorption band:100MHz–3GHz; Absorption coefficient ≥0.9; B1 flame retardant grade | 50 | ㎡ | KITOZER | Suppress indoor electromagnetic wave reflection & reverberation |
| 14 | Anti-Static Floor | KITOZER-ES100-600 | 600×600mm anti-static ceramic tile with shielding layer; Surface resistance 10⁶–10⁹Ω; Load-bearing ≥1500kg/㎡; Dual insulation & anti-static function | 80 | ㎡ | KITOZER | Indoor anti-static & shielding protection |
6. Full Product Technical Specifications
6.1 Shielding Enclosure

Shielded Electrical Cabinet Interior
- Material: Basic tier – 1.5mm corrugated galvanized steel; Mid tier – 2mm cold-rolled galvanized steel; High-end tier –3mm galvanized steel with 2mm stainless steel inner wall
- Shielding Effectiveness: Basic ≥60dB @10kHz–1GHz; Mid ≥80dB @10kHz–3GHz; High-end ≥100dB @10kHz–3GHz
- Structural Precision: Flatness 5–10mm/2m; Verticality 3–8mm; Earthquake resistance ≥Grade 8
- Deformation Control: Roof sag ≤5–8mm & floor depression ≤0.5mm within 5 years
- Joint Technology: Basic – lap joint sealing; Mid – bolt + conductive gasket; High-end – full welding + sealing glue
6.2 Shielded Door
- Material: Basic –1.5mm galvanized steel; Mid –2mm galvanized steel; High-end –3mm stainless steel
- Sealing System: Basic – single-layer beryllium bronze strip; Mid – double-layer beryllium bronze strip; High-end – triple vacuum heat-treated beryllium bronze strip
- Door Interlock: Basic – mechanical; Mid – electromagnetic + infrared detection; High-end – electromagnetic + infrared + pressure triple interlock
- Service Life: Basic ≥5000 cycles; Mid ≥10000 cycles; High-end ≥20000 cycles
- Standard Sizes: Personnel door 900×1900mm; Test piece door 1800–2500mm × 2200–3500mm
6.3 Power Filter
- Rated Voltage: 380V/50Hz 3-phase, 220V optional
- Rated Current: Basic 30A; Mid 50A; High-end 100A
- Filter Bandwidth: Basic 10kHz–1GHz; Mid/High-end 10kHz–3GHz
- Insertion Loss: Basic ≥60dB; Mid ≥80dB; High-end ≥100dB
- Protection Functions: Basic – none; Mid – lightning protection; High-end – lightning + surge protection
6.4 Insulated Floor Slab

Central Control Room
- Material: Basic –3mm PP board; Mid –5mm PP board + insulated supports; High-end –8mm PP board + ceramic insulated supports
- Insulation Resistance: Basic ≥500MΩ; Mid ≥1000MΩ; High-end ≥2000MΩ
- Withstand Voltage: Basic ≥5kV; Mid ≥10kV; High-end ≥20kV
- Custom Size: Extended 0.5–1m beyond chamber dimensions for full insulation coverage
6.5 Independent Grounding System
- Ground Electrode Material: Basic – galvanized angle steel; Mid – copper-clad steel; High-end – pure copper
- Quantity of Electrodes: Basic 5 pcs; Mid 8 pcs; High-end 12 pcs
- Ground Main Bar: Basic 50mm² copper bar; Mid 70mm² copper bar; High-end 95mm² copper bar
- Ground Resistance: Basic ≤1Ω; Mid ≤0.5Ω; High-end ≤0.1Ω
- Grounding Mode: Single-point grounding + equipotential bonding to eliminate ground potential difference interference
6.6 Ventilation Waveguide Window / Ventilator
- Material: Basic – aluminum alloy + copper plating; Mid – stainless steel + nickel plating; High-end – silver-plated stainless steel
- Honeycomb Aperture: Basic 8mm; Mid 6mm; High-end 4mm
- Shielding Effectiveness: Basic ≥60dB; Mid ≥80dB; High-end ≥100dB
- Air Flow Rate: Basic ≥100m³/h; Mid ≥300m³/h; High-end ≥500m³/h
6.7 Other Auxiliary Products

Shielded Cabinet Row
- Shielded Lighting: 40–60W, 220V, SE≥60–100dB, IP54–IP66 explosion-proof
- Door Interlock Controller: 220V/380V control loop, open-door power cut, fault acoustic-light alarm + remote prompt
- Shielded Signal Interface: BNC/SMA/N types, 8–24 channels, SE≥60–100dB, 50/75Ω impedance
- Monitoring Camera: 2–4MP resolution, 120°–150° viewing angle, IP65–IP67 shielding, infrared night vision
- Wave-Absorbing Material: Polyurethane sponge,50mm thickness, absorption band 100MHz–3GHz, absorption coefficient ≥0.9
7. Product Application Scope
7.1 Core Application Scenarios
- Power Equipment Manufacturers: Factory PD tests for transformers, GIS combined electrical appliances, high-voltage switchgears, power cables, instrument transformers, insulators, lightning arresters and other high-voltage products
- Power Grid Operation & Testing Institutions: On-site PD detection, fault diagnosis and insulation condition evaluation for substation and converter station high-voltage equipment
- Research Institutes & Universities: High-voltage labs, EMC labs, insulation material research, PD mechanism research and teaching experiments
- Third-Party Testing Organizations: Type tests, certification tests and commissioned inspections for high-voltage products to provide authoritative PD test data
- New Energy Industry: PD testing for high-voltage components of photovoltaic inverters, wind power converters and energy storage equipment
7.2 Adaptable Voltage Levels for Equipment

KITOZER Shielded Control Room
- Medium/Low Voltage: 10kV, 35kV electrical equipment (instrument transformers, switchgears, cable accessories)
- High Voltage: 110kV, 220kV transformers, GIS, high-voltage cables
- Extra/Ultra-High Voltage: 500kV,750kV,1000kV transformers, converter transformers, UHV GIS
7.3 Special Applications
- Electromagnetic Shielding Labs: EMI/EMC testing, precision instrument shielding, confidential information shielding (compliant with BMB3 standard)
- Anti-Static Labs: Anti-static testing & shielding protection for electronic components and semiconductors
- Acoustic Shielding Labs: PD ultrasonic detection, noise testing and acoustic experiments (cooperated with wave-absorbing materials)
8. Product Advantages
8.1 Core Functional Advantages
- Ultra-High Shielding Effectiveness: Full 60–100dB grade coverage, wide-band interference suppression from 10kHz–3GHz, background noise as low as 0.1–2 pC to support ultra-sensitive pC-level PD testing
- Extreme Insulation Isolation: Insulation resistance 500–2000MΩ, withstand voltage 5–20kV, completely blocking external ground potential interference and stray current impact on test accuracy
- Ultra-Low Background Noise: Fully sealed shielding + wave-absorbing materials (high-end tier) suppress electromagnetic reflection and reverberation, background noise limited to 0.1–2 pC to capture faint authentic PD signals
- Safe & Reliable: Multi-layer door interlocks, high-voltage interlocks, emergency stop and leakage protection eliminate risks of high-voltage electric shock and electromagnetic radiation to protect personnel and equipment
8.2 Customization & Service Advantages
- Full-Dimensional Customization: Customizable size (5–100 ㎡), shielding grade (60–100dB), structural technology (corrugated/modular/welded) and functional configuration (basic/intelligent/premium) to match site and testing requirements
- OEM & ODM Processing: OEM/ODM manufacturing of core components including shielding enclosures, shielded doors and filters, supporting customer brand and parameter customization
- Strict Confidentiality Mechanism: Confidentiality agreements signed to fully protect customer technical parameters, drawings and project information against technical leakage
- Fast Delivery of Stock Goods: Standard specifications (5–10 ㎡,60–80dB) in stock for delivery & installation within 7–15 days; customized orders delivered within 30–45 days to shorten project cycles
8.3 Technical & Process Advantages
- Premium Raw Materials: Baosteel galvanized steel, imported beryllium bronze sealing strips, pure copper/copper-clad steel grounding electrodes, corrosion-resistant with ≥20-year service life
- Advanced Manufacturing Technology: Laser cutting, CNC bending, precision welding and dust-free assembly guarantee flatness, verticality and sealing of shielding enclosures with stable non-degrading shielding performance
- Detachable & Reusable: Modular structures can be disassembled and relocated with ≥90% reusability to cut relocation & reconstruction costs, eco-friendly & cost-effective
- Complete Transparent Technical Parameters: Full low/mid/high tier specifications with verifiable parameters, supporting third-party inspection & certification for guaranteed performance
8.4 Cost & Maintenance Advantages
- High Cost Performance: Tiered pricing matching all budgets – economical basic tier, balanced mid tier, top-performance high-end tier
- Low Maintenance Cost: Detachable replaceable sealing strips without professional labor, few wearing parts, annual maintenance cost ≤500 RMB to reduce long-term operating expenses
- Long Service Life: All-metal anti-corrosion structure with ≥20-year service life under standard operating conditions, one-time investment for long-term benefits
9. Bid Specification Parameters (Marked with *)
9.1 Shielding Enclosure
-
- Shield Material: ≥2mm galvanized steel sheet (mid & high-end tiers), formed by laser cutting & CNC bending
-
- Shielding Effectiveness: ≥80dB (mid tier) / ≥100dB (high-end tier) @10kHz–3GHz, third-party test report provided
-
- Structural Precision: Flatness ≤8mm/2m, verticality ≤5mm, earthquake resistance ≥Grade 8
-
- Deformation Control: Roof sag ≤5mm & floor depression ≤0.5mm within 5 years
-
- Joint Technology: Modular type sealed with M8 galvanized bolts + conductive gaskets; full welded type fully welded + sealing glue treatment
9.2 Shielded Door
-
- Door Material: ≥2mm galvanized steel (mid tier) / ≥3mm stainless steel (high-end tier)
-
- Sealing System: Double-layer (mid tier) / triple-layer (high-end tier) vacuum heat-treated beryllium bronze elastic strips, detachable design
-
- Door Interlock Function: Electromagnetic + infrared detection (mid tier) / triple interlock (high-end tier), power cut when doors open, power restored when closed, service life ≥10000 cycles
-
- Door Opening Size: Test piece door ≥2000×3000mm, personnel door ≥900×1900mm
9.3 Power Filter
-
- Rated Current: ≥50A (mid tier) / ≥100A (high-end tier), compatible with 380V 3-phase power supply
-
- Filter Bandwidth:10kHz–3GHz, insertion loss ≥80dB (mid tier) / ≥100dB (high-end tier)
-
- Protection Functions: Lightning protection (mid tier) / lightning + surge protection (high-end tier)
9.4 Insulated Floor Slab
-
- Insulation Material: ≥5mm PP board + insulated supports (mid tier) / ≥8mm PP board + ceramic insulated supports (high-end tier)
-
- Insulation Resistance: ≥1000MΩ (mid tier) / ≥2000MΩ (high-end tier), withstand voltage ≥10kV (mid tier) / ≥20kV (high-end tier)
9.5 Independent Grounding System
-
- Ground Electrode Material: Copper-clad steel (mid tier) / pure copper (high-end tier), quantity ≥8 pcs (mid tier) / ≥12 pcs (high-end tier)
-
- Ground Resistance: ≤0.5Ω (mid tier) / ≤0.1Ω (high-end tier), single-point grounding + equipotential bonding
9.6 Ventilation Waveguide System
-
- Honeycomb Aperture: ≤6mm (mid tier) / ≤4mm (high-end tier), shielding effectiveness ≥80dB (mid tier) / ≥100dB (high-end tier)
-
- Air Flow Rate: ≥300m³/h (mid tier) / ≥500m³/h (high-end tier), low-noise design
9.7 Overall System
-
- Background Noise: ≤1 pC (mid tier) / ≤0.5 pC (high-end tier) under no-load test circuit conditions
-
- Compliance Standards: Comply with GB/T12190-2006 & GB/T51103-2015 national standards, inspection reports provided
10. Full Product Solution Packages
10.1 Economical Solution for Small Manufacturers (60dB Basic Tier, 5–10 ㎡)
- Applicable Scenarios: Conventional PD testing for low-voltage electrical appliances, small instrument transformers and 10–35kV switchgears, small manufacturing enterprises with limited budgets
- Core Configuration: Corrugated shielding enclosure, single-leaf personnel door + double-leaf test piece door, 30A power filter, 3mm PP insulated floor, basic grounding system, standard lighting & interlock
- Solution Advantages: Low cost, fast construction (7 days), simple operation, low maintenance cost to meet basic PD testing requirements
- Implementation Process: Site survey → scheme design → manufacturing → on-site installation → commissioning & testing → delivery training, one-stop full service
10.2 Standard Solution for Mid-Size Manufacturers (80dB Advanced Tier,10–50 ㎡)
- Applicable Scenarios: PD testing for mainstream high-voltage products including 110–220kV transformers, GIS and high-voltage cables, mid-size power equipment manufacturers and third-party testing institutions
- Core Configuration: Modular shielding enclosure, lockable personnel door + rotatable test piece door, 50A high-performance filter, 5mm reinforced insulated floor, precision grounding system, waveguide ventilators, intelligent interlock, monitoring & T&H monitoring
- Solution Advantages: Balanced shielding performance & cost, detachable & relocatable, background noise ≤1 pC, intelligent safety control compatible with most high-voltage product testing demands
- Implementation Process: Site survey → customized design → manufacturing (15 days) → on-site installation (10 days) → shielding effectiveness inspection → debugging & calibration → delivery training → after-sales warranty
10.3 Premium Solution for Large Enterprises & Research Institutes (100dB Professional Tier, ≥50 ㎡)
- Applicable Scenarios: High-precision experiments for 500kV & above UHV equipment, EMC testing, confidential shielding, large power groups and national-level research institutions
- Core Configuration: Full welded shielding enclosure, premium single-leaf door + oversized double-leaf test piece door, 100A ultra-high performance filter, 8mm ultra-high strength insulated floor, ultra-low resistance grounding system, customized waveguide ventilation, industrial-grade interlock, HD monitoring, wave-absorbing materials, anti-static flooring
- Solution Advantages: Top-tier shielding performance (≥100dB), background noise ≤0.5 pC, ultra-high insulation isolation, full intelligent control, long service life for highest-precision testing demands
- Implementation Process: Site survey + environmental assessment → in-depth customized design → raw material procurement → precision manufacturing (30 days) → foundation treatment → welded installation (20 days) → full shielding effectiveness inspection → system debugging → calibration & certification → delivery training → lifetime technical support
10.4 Special Scenario Solutions for Floor & Pit Installation
- Floor-Lightweight Solution: Lightweight modular structure with optimized load-bearing capacity (≤600kg/㎡), lightweight shielded doors and reinforced keels for installation on the second floor and above without special foundations
- Pit-Mounted Solution: 300–500mm underground pit with double insulation + shielding layers and waterproof sealing treatment, enhanced insulation performance for testing requiring ultra-high insulation standards
10.5 Renovation & Upgrade Solution for Aged Shielded Chambers
- Renovation Contents: Replace aged sealing strips, reinforce enclosure joints, upgrade power filters, optimize grounding systems, update interlock & monitoring systems, add inner wall wave-absorbing materials
- Renovation Effect: Shielding effectiveness improved by 20–40dB, background noise reduced below 1 pC, service life extended by over 10 years, cost only 30–50% of new construction
11. Product Application Cases
11.1 Transformer Manufacturer Project (80dB Mid Tier,8m×6m×4m)
- Project Background: Specialized in manufacturing 110–220kV power transformers, requiring a PD shielding chamber for factory testing, located on the first floor of a spacious workshop
- Configuration List: Modular shielding enclosure, 2m×3m double-leaf test piece door, 0.9m×1.9m single-leaf personnel door, 50A power filter, 5mm insulated floor, copper-clad steel grounding system, waveguide ventilators, intelligent interlock & monitoring system
- Implementation Outcome: Shielding effectiveness 85dB @10kHz–3GHz, background noise 0.8 pC, fully meeting 220kV transformer PD testing requirements; 3 years of failure-free stable operation with consistent test data, highly recognized by the customer
11.2 National Research Institute High-Voltage Lab Project (100dB High-End Tier,12m×10m×5m)
- Project Background: National-level high-voltage lab conducting PD mechanism research on 500kV UHV transformers and GIS, demanding ultra-high shielding performance and ultra-low background noise
- Configuration List: Full welded shielding enclosure, 2.5m×3.5m oversized double-leaf test piece door, 3mm stainless steel personnel door, 100A ultra-high performance filter, 8mm insulated floor, pure copper ultra-low resistance grounding, customized waveguide ventilation, industrial-grade interlock, HD monitoring, 50mm wave-absorbing materials, anti-static flooring
- Implementation Outcome: Shielding effectiveness 105dB @10kHz–3GHz, background noise 0.3 pC, satisfying high-precision testing for UHV equipment; supporting multiple national key research projects with internationally leading data accuracy
11.3 Small Switchgear Manufacturer Project (60dB Basic Tier,6m×5m×3m)
- Project Background: Manufacturer of 10–35kV high-voltage switchgears with tight budget, requiring an economical PD shielding chamber for routine factory testing
- Configuration List: Corrugated shielding enclosure, 1.8m×2.2m double-leaf test piece door, 0.9m×1.9m single-leaf personnel door, 30A power filter, 3mm PP insulated floor, galvanized angle steel grounding, standard lighting & interlock
- Implementation Outcome: Shielding effectiveness 65dB @10kHz–1GHz, background noise 1.5 pC, fully compliant with 35kV switchgear PD testing; low cost with 7-day fast installation delivering significant cost savings for the enterprise
11.4 Power Grid Operation & Testing Center Project (80dB Mid Tier,7m×5m×4m)
- Project Background: Responsible for on-site PD detection of 110–220kV substation equipment, requiring relocatable small shielding chambers for field testing
- Configuration List: Detachable modular shielding enclosure, 2m×3m double-leaf test piece door, intelligent interlock, portable power filter, insulated floor, quick-assembly grounding system
- Implementation Outcome: Shielding effectiveness 82dB, background noise 0.9 pC, fully disassembled & assembled by 2 workers within 1 day for deployment at different substations, drastically improving operation & testing efficiency
12. Product Faults & Maintenance Guidelines
12.1 Common Faults & Troubleshooting
- Reduced Shielding Effectiveness
- Root Causes: Aged/damaged sealing strips, loose joints, poor grounding, shield body corrosion
- Solutions: Replace aged detachable sealing strips, fasten joint bolts, inspect & repair grounding systems, conduct rust removal & anti-corrosion treatment
- Excessively High Background Noise (>2 pC)
- Root Causes: Power interference (failed filter), ground interference (excessive grounding resistance), strong external electromagnetic interference, indoor electromagnetic reflection (no wave-absorbing materials)
- Solutions: Inspect & replace power filters, optimize grounding systems to reduce resistance ≤0.5Ω, avoid strong external interference sources such as high-voltage lines and large motors, install wave-absorbing materials on inner walls
- Sticky Shielded Door Operation / Interlock Malfunction
- Root Causes: Deformed sealing strips, loose door hinges, faulty interlock controller, damaged travel switches
- Solutions: Adjust or replace sealing strips, fasten hinge screws, overhaul interlock controllers, replace damaged travel switches
- Declined Insulation Resistance of Insulated Floor Slab
- Root Causes: Damaged insulation boards, water ingress & damp joint seams, aged cracked insulated glue
- Solutions: Repair broken insulation boards, dry damp areas and re-seal, replace aged insulated glue to ensure full insulation coverage
- Noisy Ventilation System / Insufficient Air Flow
- Root Causes: Worn fan bearings, clogged honeycomb holes, abnormal fan speed
- Solutions: Replace fan bearings, clear honeycomb blockages, overhaul fan motors to restore rated speed
12.2 Routine Maintenance Regulations
- Daily Maintenance
- Inspect intactness & smooth operation of shield door sealing strips, verify normal interlock function
- Monitor normal background noise (≤1 pC) inside the chamber for abnormal interference signals
- Check normal operation of lighting, monitoring and ventilation systems
- Weekly Maintenance
- Clean shield door sealing strips and waveguide window honeycombs to remove dust & debris that degrade shielding performance
- Fasten loose shielding enclosure joint bolts
- Test insulation resistance of insulated floor slab (≥1000MΩ) and record data
- Monthly Maintenance
- Inspect tight connection of grounding systems and verify compliance of grounding resistance (≤0.5Ω)
- Calibrate power filters and signal interfaces to maintain filtering & shielding performance
- Clean indoor environment, check for water accumulation & dampness, keep dry & ventilated
- Annual Maintenance
- Full shielding effectiveness testing, commission third-party institutions to issue inspection reports
- Replace aged sealing strips, inspect shield body corrosion and conduct rust removal & anti-corrosion treatment
- Overhaul all electrical equipment (filters, interlocks, monitoring, ventilators) and replace wearing parts
- Inspect aging & peeling of wave-absorbing materials (high-end tier), repair or replace as required
12.3 Maintenance Precautions
- Flammable, explosive and corrosive materials are strictly prohibited inside the shielding chamber to avoid damage to shield bodies and insulation layers
- Unauthorized structural modification or disassembly of shielding components is forbidden; contact factory technical staff for any reconstruction demands
- Cut off high-voltage power supply before maintenance and follow high-voltage safety operation procedures to prevent electric shock accidents
- Sealing strips are wearing parts; reserve 1–2 spare sets for quick replacement
13. Factory Strength & After-Sales Service
13.1 Factory Strength
- Production Scale: 10,000 ㎡ modern production workshop with 5 dedicated shielding chamber production lines, annual output exceeding 500 sets, a leading domestic R&D & manufacturing enterprise for electromagnetic shielding equipment
- Technical Team: Core technical team of over 20 senior engineers specializing in high voltage, EMC and mechanical design with average industry experience ≥10 years, holding multiple core shielding chamber technology patents
- Production Equipment: Imported German laser cutters, Japanese CNC bending machines, fully automatic welding robots and dust-free assembly workshops for high-precision standardized production with stable product quality
- Quality System: ISO9001 quality management system, ISO14001 environmental management system and CE certification; 100% factory inspection for all products with 100% qualification rate, complying with national standards and internal enterprise control standards
- R&D Capacity: Continuous R&D investment launching 2–3 new technologies & products annually, tracking cutting-edge high-voltage testing and electromagnetic shielding technology to maintain industry technical leadership
13.2 After-Sales Service Commitments
- Warranty Period: 2-year free warranty for all products (from acceptance date), 5-year warranty for core components (shielding enclosure, grounding system); free repair & replacement of non-artificial damaged parts within warranty, no labor or travel fees charged
- Lifetime Technical Support: 24-hour technical consultation via phone/WeChat/remote guidance after warranty expiration, rapid response to customer issues with targeted solutions
- Rapid Repair Service: Respond within 2 hours upon fault notification, arrive on-site within 24 hours nationwide, eliminate faults within 48 hours to minimize production downtime losses
- Free Installation & Commissioning: Free on-site installation, commissioning and calibration to guarantee shielding chamber performance compliance; free technical training for operators covering operation, maintenance and fault handling to enable independent operation & maintenance
- Customized Service: Free on-site survey, scheme design and technical consultation based on customer demands; support product customization, OEM processing and technical renovation for personalized requirements
- Spare Parts Support: Complete spare parts warehouse stocking common components (sealing strips, filters, interlock controllers) for fast supply and shortened repair cycles
13.3 Service Network
- Domestic: 5 major service centers established in South China, East China, North China, Southwest China and Northwest China, 24-hour nationwide coverage for rapid customer response
- Overseas: Global delivery and technical guidance available, products exported to over 30 countries & regions including Southeast Asia, Middle East, Europe and Africa with wide recognition from overseas customers
14. Conclusion
As core supporting equipment for high-voltage testing, KITOZER shielded partial discharge chambers feature ultra-high shielding effectiveness, extreme insulation isolation, ultra-low background noise, reliable safety and full customized service as core competitive strengths, covering full low/mid/high shielding grades to match all budget and testing demands. Complying strictly with national standards and manufactured with premium raw materials & advanced processes, the products deliver stable reliable quality and long service life, widely deployed in power equipment manufacturing, power grid operation, research institutes and third-party testing sectors to help customers realize high-precision, high-efficiency partial discharge testing.
Moving forward, KITOZER will deepen R&D in electromagnetic shielding and high-voltage testing technology, continuously innovate products, optimize performance and service systems, and deliver higher-quality products, professional technology and comprehensive services to meet growing customer testing demands, contributing to high-quality development of the power industry.
15. Search Keywords, SEO & Tags
15.1 Core Search Keywords
Shielded Partial Discharge Chamber, Partial Discharge Shield Room, High-Voltage PD Shield Room, Transformer PD Shield Room, GIS PD Shield Room, Cable PD Shield Room, Electromagnetic Shielding Chamber, 60dB Shield Room, 80dB Shield Room, 100dB Shield Room, PD Laboratory, High-Voltage Shielded Test Laboratory
15.2 Long-Tail Search Keywords
KITOZER Shielded Partial Discharge Chamber, Modular Shielded PD Chamber, Full Welded Shielded PD Chamber, Economical Shielded PD Chamber, Standard Shielded PD Chamber, Premium Shielded PD Chamber, Floor-Lightweight Shielded PD Chamber, Pit-Mounted Shielded PD Chamber, Shielded PD Chamber Solution, Shielded PD Chamber Configuration List, Shielded PD Chamber Technical Parameters, Shielded PD Chamber Application Cases
15.3 Optimized SEO Titles
- KITOZER Shielded Partial Discharge Chamber – Custom High-Voltage PD Test Shield Room Manufacturer
- Shielded Partial Discharge Chamber Solution – Full 60/80/100dB Grades – Dedicated for Transformer/GIS/Cable Testing
- High-Voltage PD Shield Room – Electromagnetic Shielding Lab – High-Precision PD Testing – Direct Manufacturer Supply
15.4 Web Meta Tags
- Title: KITOZER Shielded Partial Discharge Chamber | High-Voltage PD Shield Room | Custom Manufacturer | Complete Solutions
- Keywords: Shielded Partial Discharge Chamber, PD Shield Room, High-Voltage PD Shield Room, Electromagnetic Shielding Chamber, PD Laboratory
- Description: KITOZER specializes in R&D and manufacturing of shielded partial discharge chambers, providing full 60/80/100dB shielding chamber solutions for PD testing of transformers, GIS, cables and other high-voltage equipment. Customized manufacturing, reliable quality and comprehensive after-sales service.