KITOZER
KITOZER

KITOZER Signal EMI Filter: 10 MHz Low Pass Analog

Product Overview

The KITOZER 10 MHz low pass signal EMI filter protects analog sensor lines, instrumentation wires, and low frequency communication circuits from radio frequency interference and conducted noise without attenuating the wanted measurement bandwidth. It uses a balanced RLC topology that passes the desired signal below the cutoff while shunting high frequency common mode noise to chassis ground. This design preserves the integrity of millivolt level transducer signals that would otherwise be corrupted by nearby switching equipment, motor drives, and radio transmitters.

Analog measurement chains depend on clean conductors. A 4 to 20 milliamp loop or a 0 to 10 volt sensor output carrying microvolt-level noise from a variable speed drive becomes unreadable or drifts out of tolerance. The KITOZER filter sits at the cabinet entry or the equipment input and removes that radio frequency pickup before it reaches the analog-to-digital converter. Because it is balanced, it does not unbalance the pair, preserving the high common mode rejection ratio that differential inputs rely on.

Technical Specifications

Cutoff frequency 10 MHz low pass, differential mode pass band flat to 10 MHz, characteristic impedance 100 ohms balanced. Insertion attenuation greater than 60 dB from 30 MHz to 1 GHz. Signal current up to 100 mA per line, isolation voltage 500 volts between line and ground. Operating temperature minus 40 to plus 85 degrees Celsius. Compact shielded metal block with screw terminals, CE certified, suitable for analog 4 to 20 mA, 0 to 10 volt, and RS485 physical layer wiring.

The balanced design uses matched series inductors on both conductors and a balanced capacitor network to ground. The shielded metal block connects to the cable shield, and the terminal layout keeps the input and output compartments separated. The through-line rating accommodates loop-powered transmitters without an external supply, and the 500 volt isolation protects the analog front end from ground potential differences between field and control room.

Applications

Install this filter on the output of pressure, temperature, and load cell transmitters in factories with high frequency welders and induction heaters. It is also used on medical patient monitor leads, audio microphone lines, and security camera analog outputs where radio frequency ingress causes humming, buzzing, or measurement drift. Engineers add it at the cabinet entry to suppress noise picked up by long field cables running near variable speed drives.

In a steel mill it cleans the load cell signals feeding the batch scale so that weighments stay accurate despite the nearby induction furnaces. In a hospital it quiets the ECG lead runs near surgical equipment. In an audio broadcast room it removes the buzz from dimmer circuits. The filter is also useful on RS485 and Modbus field buses, where common mode noise can corrupt frames and cause intermittent communication faults.

Selection is straightforward: match the filter cutoff to the signal bandwidth, choose the balanced or unbalanced variant to match the line, and confirm the through-current covers the loop supply. For multi-drop RS485 networks, install a filter at each sensitive node rather than a central point, because noise couples at every cable entry. The result is a measurement chain that stays stable across seasons and load changes, with fewer spurious alarms and less time spent chasing phantom readings.

Advantages and Features

The balanced topology ensures that common mode noise is rejected equally on both conductors, preserving the common mode rejection ratio of the analog front end. The shielded metal block provides 360 degree cable entry when used with appropriate EMI cable glands, preventing the filter itself from becoming a radiating source. Low insertion loss in the pass band means signal conditioning accuracy is not compromised, and the through-line current rating accommodates loop powered transmitters without an external supply.

Because the filter does not require power and introduces no active circuitry, it cannot fail in ways that interrupt the measurement. The screw terminals accept both solid and stranded wire, and the compact block mounts on a DIN rail or panel. The published cutoff and attenuation curves let engineers choose the right filter for the signal bandwidth rather than guessing.

Installation and Maintenance

Mount the filter at the equipment end of the shielded cable and bond the cable shield to the filter chassis with a 360 degree gland rather than a pigtail. Keep the filtered and unfiltered sides separated inside the enclosure. Verify signal bandwidth with a pulse or frequency test before production. No maintenance is required beyond periodic terminal checks; replace the module if attenuation is compromised.

During commissioning, compare the measured reading with a reference multimeter to confirm the filter did not insert a DC error. In dusty or corrosive environments inspect terminals annually and retighten as needed. Avoid using the filter on signals above its 10 MHz pass band, such as high-speed data, because the cutoff would then distort the wanted signal.

Price

From $12 per piece. Contact plus 86 13922289957 for pricing. Multi-channel versions for sensor banks available.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com