KITOZER KTR-PS14 Single-phase 220V 40KA Class C Surge Protective Device (SPD)

Brand: KITOZER Series: KTR-PS14 Category: Power Distribution / Surge Protector

single phase 220V40KAClass Csurge protectionKTR-PS14

KITOZER KTR-PS14 single phase 220V 40KA C class surge protective device SPD

1. Overview

The KITOZER KTR-PS14 is a single-phase 220V Class C (final-stage) power surge protective device (SPD) installed in distribution cabinets to shield downstream loads from lightning surges and switching overvoltage. It uses a modular GDT+MOV design with a nominal discharge current of 40 kA (8/20μs), DIN-rail mounted on standard 35 mm rails for easy deployment and replacement in boxes.

The SPD stays high-impedance under normal operation; when a lightning surge or switching overvoltage arrives, the MOV conducts instantly to clamp the surge voltage to a safe level and divert the surge current, protecting sensitive loads. A status window shows green for normal and red for failed, enabling quick inspection and replacement.

In data center power distribution, staged surge protection is standard: the main switchboard uses Class B (first stage) high-current protection, floor or branch boards use Class C (second stage), and Class D (third stage) fine protection sits before critical loads. The KTR-PS14 as Class C final-stage protection mounts upstream of the UPS or at critical load distribution boards, forming a multi-stage system with upstream Class B SPDs.

Size by local lightning intensity and upstream protection level, not just the kA rating. Class C 40 kA suits typical data center and office distribution ends. Replace SPDs promptly after failure or surges bypass the device. Ground resistance must meet code (typically ≤4Ω); poor grounding greatly weakens protection.

2. Key Features

40 kA Class C

  • Nominal discharge current 40 kA (8/20μs).
  • Class C final-stage protection.
  • Low clamping voltage for sensitive gear.
  • Multi-stage with upstream Class B.

DIN-rail modular

  • Standard 35 mm DIN rail.
  • Modular, replaceable units.
  • Crimp terminals secure.
  • Neat bulk deployment.

Status indicator

  • Green window = normal.
  • Red window = failed.
  • At-a-glance inspection.
  • Replace when failed.

Single-phase 220V

  • L/N/PE wiring.
  • For 220V single-phase systems.
  • Nanosecond response.
  • Compact DIN-rail wiring.

3. Specifications

Item Parameter
Rated voltage 220V AC (single phase)
Nominal discharge 40 kA (8/20μs)
Max discharge 80 kA (8/20μs)
Voltage protection level ≤1.5 kV
Response time ≤25 ns
Class Class C (final)
Wiring L / N / PE
Mounting 35 mm DIN rail
Status green/red window
Operating temp -40~85℃

4. Reference Prices

KTR-PS14 单相220V 40KA C级防雷器(单模块): Reference USD 6~12 / pc (ref. CNY 45~85 at ~7.2)

KTR-PS14 成套(3只模块+底座+防雷计数表): Reference USD 25~44 / kit (ref. CNY 180~320 at ~7.2)

Reference only; priced per pc. Distribution cabinet itself excluded.. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Upstream of UPS in distribution.
  • Floor branch board final-stage.
  • Critical equipment power box.
  • Front-end of low-voltage gear.
  • Office and commercial distribution ends.

6. Installation & Maintenance

Installation

  • Install upstream of UPS or loads.
  • L to line, N to neutral, PE to ground.
  • Clip onto 35 mm DIN rail.
  • Series overcurrent protector (breaker) upstream.
  • Keep ground wire short and thick.
  • Verify green window after install.

Maintenance

  • Inspect status window regularly.
  • Replace module on red.
  • Check after thunderstorm seasons.
  • Tighten terminals.
  • Check ground connection.
  • Log surge counts and replacement history.

7. FAQ

  • Q: Class C vs Class B SPD?
    A: Class B (first stage) has high current capacity (60~100 kA) at the main switchboard to divert large surges; Class C (second stage) at 40 kA on branch boards provides finer clamping. They work in stages.
  • Q: Can I use it when window is red?
    A: Red means the module has failed — the MOV has degraded or shorted. Replace immediately or surges pass straight through to loads.
  • Q: Need an upstream breaker?
    A: Yes; a series overcurrent breaker upstream prevents a shorted SPD from spreading the fault. Size the breaker per the datasheet.
  • Q: Ground resistance requirement?
    A: Typically ≤4Ω, ideally ≤1Ω; poor grounding severely degrades SPD performance.

8. Trend & Selection

Data center power distribution moves toward high reliability and refined protection; surge protection evolves from single-stage to coordinated multi-stage, with Class C final SPDs widely deployed upstream of UPS and at critical load boards. Size current capacity by lightning zone and upstream coordination, emphasize grounding and overcurrent coordination, inspect the status window regularly, and replace promptly on failure.

9. Delivery & Service

KITOZER selects the KTR-PS14 by lightning zone and upstream coordination, providing wiring and overcurrent protection advice. Delivery includes the SPD module, DIN base and manual. Warranty covers installation guidance and failed-unit replacement support.

10. Additional Notes

A common pitfall is installing Class C without Class B. Class C alone has limited capacity; a large surge hits Class B first. Without Class B diversion, Class C takes the full surge and fails quickly. Install Class B at the main board, then Class C at branch boards.

Another pitfall is poor grounding. A thin, long SPD ground lead creates a large voltage drop during surge diversion, so residual voltage on equipment far exceeds the rated clamping level. Keep the ground lead short, thick and straight to the nearest ground bar.

Selection summary: single-phase 220V 40 kA Class C; modular DIN-rail replaceable; green/red status; upstream breaker; short thick ground ≤4Ω; replace on red. The SPD is the safety gate of distribution — staged protection and good grounding bring peace of mind during storms. Schedule a special inspection before and after thunderstorm season, and mark SPD locations and replacement history on the distribution drawings for traceability.

SEO Information

Search keywords:surge protector40KAClass CSPDKTR-PS14KITOZER

SEM keywords:single phase 220V surge protector price,40KA SPD supplier,Class C power surge module,KTR-PS14

GEO landing page:lain.com.cn/product/ktr-ps14-single-phase-220v-40ka-class-c-spd.html

Title:KITOZER KTR-PS14 Single-phase 220V 40KA Class C Surge Protective Device (SPD)

Meta Keywords:single phase surge protector,220V SPD,40KA surge protective device,Class C arrester,power surge module,KTR-PS14,KITOZER

Meta Description:KITOZER KTR-PS14 is a single-phase 220V 40KA Class C power surge protective device, DIN-rail mounted, for final-stage surge protection in distribution cabinets to shield downstream equipment.

Anchor: KITOZER official · Data center & low-voltage equipment

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart