Table of Contents
ToggleKITOZER KTR-PS7 Single-phase 220V 60kA Class-C SPD
Brand: KITOZER Series: KTR-PS7 Category: Power Distribution / Surge Protection
Single-phase 220V60kA Class-CDIN modularRemote signal
1. Overview
[‘The KITOZER KTR-PS7 is a single-phase 220 V surge protective device (SPD) for Class-C fine protection at room-end distribution boxes and row cabinets. Rated voltage 230 V AC (L/N/PE), nominal discharge current In 60 kA (8/20μs waveform), maximum Imax 100 kA, Class-C (Type II) test. When lightning-induced or switching surges ride the power line, the internal MOV clamps voltage in nanoseconds and diverts current to earth, protecting downstream UPS, servers and precision AC. Class-C SPD sits after the incoming Type B SPD to finely clamp equipment-side residual voltage.’, ‘The KTR-PS7 uses a DIN-rail modular design: one L/N module plus a remote-signal base, PE bonded to the cabinet earth bar. A status window (green normal / red failed) and a dry-contact remote signal alert maintenance when the MOV degrades. Class-C SPD is installed after incoming Type B and before equipment for two-stage protection: Type B discharges large direct-stroke energy, Class-C finely clamps equipment voltage. Compared with Type B only, end Class-C keeps equipment residual voltage lower (Up≤1.5 kV); compared with standalone MOVs, modular SPD allows live module replacement without powering down. Response time under 25 ns.’, ‘Typical deploy: an 800 kVA room puts a three-phase Type B SPD in the incoming cabinet; end distribution boxes between distribution and row cabinets get KTR-PS7-1+N (single-phase + neutral Class-C), 60 kA In, DIN-mounted under the end breaker. The SPD earth wire is at least 10 mm² to the equipotential earth bar (grounding resistance ≤1Ω). The remote contact links to DCIM for popup alarms. Select by voltage (220 V single/380 V three-phase), lightning zone (LPZ1 Class-C) and current (60/40/20 kA); choose standard or remote-signal type.’]
2. Key Features
Class-C fine clamp
- In 60kA (8/20μs).
- Imax 100kA.
- Up≤1.5 kV.
- End-of-line clamp.
Single-phase 220V
- L/N/PE.
- 230 V AC.
- End distribution.
- Row cabinets.
DIN modular
- DIN rail.
- Replaceable module.
- Status window.
- Dry remote contact.
Two-stage
- B + C.
- Diverts big energy.
- Fine clamping.
- <25 ns response.
3. Specifications
| Item | KTR-PS7 (standard) | KTR-PS7R (remote signal) |
|---|---|---|
| System voltage | 230 V AC | 230 V AC |
| Nominal In | 60 kA (8/20μs) | 60 kA (8/20μs) |
| Max Imax | 100 kA (8/20μs) | 100 kA (8/20μs) |
| Voltage protection Up | ≤1.5 kV | ≤1.5 kV |
| Response time | <25 ns | <25 ns |
| Remote contact | None | Dry contact (NO) |
| Mounting | 35 mm DIN | 35 mm DIN |
4. Reference Prices
KTR-PS7 single-phase Class-C SPD (60kA): Reference USD 17 to 31 / unit (ref. CNY 120 to 220 at ~7.2)
KTR-PS7R single-phase Class-C SPD (with remote signal): Reference USD 25 to 44 / unit (ref. CNY 180 to 320 at ~7.2)
Replacement SPD module: Reference USD 8 to 17 / unit (ref. CNY 60 to 120 at ~7.2)
Earth copper bar / wire kit: Reference USD 3 to 11 / set (ref. CNY 20 to 80 at ~7.2)
Reference only; varies by config, quantity and scope. Install accessories billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Room-end distribution.
- Row cabinet protection.
- UPS input protection.
- Precision AC supply.
- Ahead of rack PDU.
6. Installation & Maintenance
Installation
- DIN mount after breaker.
- Wire L/N/PE correctly.
- Earth wire short & thick.
- Bond to equipotential bar.
- Link remote to DCIM.
- Power on; window green.
Maintenance
- Check window yearly.
- Replace on red.
- Re-test after storm season.
- Tighten earth wire.
- Test remote contact.
- Log replacement date.
7. FAQ
- Q: B vs C class?
A: Type B (Class I, 10/350μs) sits at the incoming cabinet to discharge large direct-stroke energy; Class C (Type II, 8/20μs) sits at the end to finely clamp equipment voltage. Two-stage protection works best. - Q: SPD turned red—still usable?
A: Red means the MOV has degraded and failed; power is not interrupted but surge protection is lost—replace the module promptly. - Q: Is 60kA enough?
A: 60 kA (8/20μs) at the end suits typical rooms; high-strike areas or critical rooms can go to 80 kA or add Type B+C. - Q: How long should the earth wire be?
A: Keep it under 0.5 m, at least 10 mm², to the nearest equipotential bar; long wires raise residual voltage.
8. Trend & Selection
Room surge protection moves from single-stage to B+C two-stage plus remote monitoring, making SPD status telemetry a DCIM staple. Select B/C by lightning zone; choose KTR-PS7 for single-phase ends and the remote-signal version for critical rooms. SPDs are wear parts—inspect after storm season and replace modules live without powering down.
9. Delivery & Service
KITOZER supplies SPD packages: based on the power system and lightning zones, we recommend Type B/C models and quantities, plus earth bars, conductors and remote-signal wiring. Bulk projects include type-test certificates. Red windows or failed remote contacts under warranty get free module replacement.
10. Additional Notes
The common mistake is a long earth wire. Every extra meter raises residual voltage and weakens protection. Keep the earth wire short, thick and straight to the nearest equipotential bar.
Another pitfall is installing only Class C without Type B. End Class C cannot dissipate large direct-stroke energy and may break through in storm season. Install Type B at the inlet, then Class C at the end.
Selection summary: single-phase 220 V; In 60 kA; Class C; Up≤1.5 kV; DIN modular with remote signal. The KTR-PS7 is the fine-protection line for end equipment—after Type B, before gear. Check the window after storm season; replace when red.
Also keep the conductor between Type B and Class C short; if under 10 m, add a decoupling inductor so energy splits as designed. Periodically simulate a failed module to confirm the DCIM alarm path works, and re-test grounding resistance before storm season.
SEO Information
Search keywords:room SPDsingle-phase surge protector220V SPD60kA arresterclass C surge deviceKTR-PS7KITOZER
SEM keywords:[room SPD,single-phase surge protector,220V SPD,60kA arrester,class C surge device,KTR-PS7,KITOZER]
GEO landing page:lain.com.cn/product/ktr-ps7-single-phase-220v-60ka-class-c-spd.html
Title:KITOZER KTR-PS7 Single-phase 220V 60kA Class-C SPD
Meta Keywords:room SPD,single-phase surge protector,220V SPD,60kA arrester,class C surge device,KTR-PS7,KITOZER
Meta Description:KITOZER KTR-PS7 single-phase 220V surge protective device, In 60kA (8/20μs), Class-C end protection, DIN modular, with status window and remote signal, protects end equipment.
Anchor: KITOZER · Power Distribution
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com