KITOZER
KITOZER

KITOZER single phase 220V 80kA C

KITOZER KTR-PS10 Power Surge Protector / Single-phase 220V 80kA Class C

Brand: KITOZER Series: KTR-PS10 Category: Power Distribution / Power Surge Protector

power SPDsingle-phase 220V80kAClass Csurge protectorKTR-PS10

1. Overview

KITOZER KTR-PS10 is a single-phase 220V 80kA Class C power surge protective device (SPD) paralleled at the distribution panel, UPS input or critical load front-end, diverting lightning surges and switching overvoltage riding the power line. Mains enters the room from the transformer; induced lightning or large load switching produces transient high voltage (up to several kV) that travels along the line into UPS, servers and switches and burns power supplies. KTR-PS10 parallels between L, N and PE: normally high-impedance without affecting supply; during a surge it conducts instantly, diverts current to ground and clamps residual voltage within equipment tolerance.

80kA is the nominal/max discharge current (8/20 us waveform); Class C (level 3) is the final fine-protection stage installed at the sub-distribution or load front-end, with lower residual voltage close to the protected gear. Single-phase 220V means it serves single-phase AC loops (L-N-PE). Rail-mount modular, failed cartridges swap live, with a status window (green OK/red failed) and a remote-contact to the panel monitor.

In data center power, surge protection is staged: Class B (level 1) at the main, Class C (level 3) at sub-distribution, shaving the surge step by step. KTR-PS10 is the Class C final stage close to UPS and precision power distribution, a common room-power accessory.

2. Key Features

Single-phase 220V

  • L-N-PE parallel protection.
  • For single-phase AC loops.
  • Clamps residual voltage for downstream gear.

80kA discharge

  • 80kA (8/20 us) discharge.
  • Class C final fine protection.
  • Close to UPS/loads.

Rail modular

  • 35mm rail-mount.
  • Hot-swap failed cartridges.
  • Green/red status window.

Remote contact

  • Remote contact output.
  • Uploads to panel DCIM.
  • Short thick ground.

3. Specifications

项目 KTR-PS10 KTR-PS10-40(40kA) KTR-PS10-100(100kA)
相制 单相220V 单相220V 单相220V
通流容量 80kA(8/20) 40kA(8/20) 100kA(8/20)
保护级别 C级(三级) C级(三级) B/C级
接线 L-N-PE L-N-PE L-N-PE
电压保护水平 低 低 中
安装 导轨35mm 导轨35mm 导轨35mm
状态指示 绿/红+遥信 绿/红 绿/红+遥信
应用 分配电/UPS前 末端设备 总/分配电

4. Reference Prices

KTR-PS10 单相80kA C级防雷器(导轨、状态窗、遥信): Reference USD 25~50 / unit (ref. CNY 180~360 at ~7.2)

KTR-PS10-40 单相40kA C级防雷器(末端设备): Reference USD 17~33 / unit (ref. CNY 120~240 at ~7.2)

KTR-PS10-100 单相100kA防雷器(B/C级): Reference USD 44~86 / unit (ref. CNY 320~620 at ~7.2)

Reference only; by discharge rating, stage and quantity; panel mounting and grounding excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Class C at UPS input.
  • Precision distribution and row cabinet front-end.
  • Critical load power front-end.
  • Rack PDU input.
  • Staged with main-panel Class B SPD.

6. Installation & Maintenance

Installation

  • Parallel SPD at the protected loop input.
  • Wire L/N/PE per labels.
  • Add upstream backup (fuse/MCB).
  • Short thick ground to earth bar.
  • Rail-mount; confirm green window.
  • Wire remote contact to DCIM.

Maintenance

  • Check status window quarterly.
  • Replace cartridge on red window.
  • Check SPD action after storms.
  • Test remote-contact upload.
  • Keep ground tight, corrosion-free.

7. FAQ

  • Q: Class C vs B?
    A: Class B has high discharge at the main panel for coarse protection; Class C has lower discharge and lower residual at the load for fine protection. Rooms stage both.
  • Q: Is 80kA enough?
    A: Class C 80kA is generally enough at UPS input and row cabinets; choose Class B high discharge at the main service entry. Select by position and lightning zone.
  • Q: Need a fuse ahead of SPD?
    A: Yes: a failed SPD can short and catch fire; add a dedicated backup fuse/MCB upstream to isolate it without cutting supply.
  • Q: Grounding requirement?
    A: Ground wire short and thick (per specified cross-section), to the room equipotential bar with proper resistance; long leads add inductance and residual voltage stays high.

8. Trend & Selection

Room power moves from single-stage to staged fine protection; Class C final SPDs add remote contacts and hot-swap cartridges for online monitoring. Select stage by lightning zone (B at main, C at end); choose single/three-phase by system; 80kA is common at the end; add upstream backup; ground short and thick; upload contacts to DCIM.

9. Delivery & Service

KITOZER supplies single/three-phase power SPDs in volume, configuring stage and discharge by the distribution system and lightning zones. We advise wiring and backup protection. Delivery includes SPD modules, rail, backup fuse and terminals. Warranty covers non-strike module failures.

10. Additional Notes

The common power-SPD pitfall is no upstream backup protection. An aged SPD fails short; without a fuse ahead, it catches fire and burns the whole box. SPDs must have a dedicated backup fuse/MCB upstream.

Another pitfall: over-long ground leads. An SPD grounded by a long run to the earth bar has high lead inductance, so residual voltage does not drop during a surge — the SPD is wasted. Ground leads must be short, thick and local to equipotential bonding.

Selection summary: stage B at main, C at end; choose phase by the system; 80kA common at the end; add upstream backup fuse; ground short and thick; upload contacts. Power SPD is the distribution fuse — unseen until a surge proves its worth.

SEO Information

Search keywords:power SPDsingle-phase 220V80kAClass Csurge protectorKTR-PS10KTR-PS10KITOZER

SEM keywords:single-phase power SPD price,80kA surge protector supplier,Class C SPD,KTR-PS10

GEO landing page:lain.com.cn/product/ktr-ps10-single-phase-220v-80ka-class-c-spd.html

Title:KITOZER KTR-PS10 Power Surge Protector / Single-phase 220V 80kA Class C

Meta Keywords:[‘power surge protector,single-phase SPD,220V surge protector,80kA SPD,Class C SPD,KTR-PS10,KITOZER’]

Meta Description:KITOZER KTR-PS10 single-phase 220V 80kA Class C power SPD parallels at the distribution panel input to divert lightning and switching surges and protect downstream loads.

Anchor: KITOZER official · Data center & low-voltage equipment

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com