ToggleProduct Overview
The KITOZER 500 L single-phase immersion cooling system is a rack-scale bath designed to replace a conventional 42U server rack with a liquid-immersed equivalent. The stainless tank houses two server baskets stacked vertically, each capable of holding up to 10 modified 1U or 2U servers, for a total IT load of 60 to 100 kW. The system ships with an integrated CDU module on the side of the tank, including redundant pumps, a plate heat exchanger, filtration, and a PLC controller, so the operator only needs to connect primary loop water and power. All electrical and network connections pass through bulkhead connectors on the lid, which stays closed during normal operation. The rack-scale form factor means the system drops into existing data hall power and network layouts without a raised-floor redesign, making it one of the fastest paths to high-density liquid cooling.
Technical Specifications
Tank volume 500 L, working fluid 420 L. Outer dimensions 1200 x 1200 x 1800 mm, internal baskets 1000 x 1000 x 700 mm each. Material stainless 304, welded and passivated. Lid aluminum with EPDM gasket, gas-strut assisted, safety interlock. Integrated CDU: two 0.55 kW magnetic-drive pumps N+1, flow 5 m3/h; plate heat exchanger 100 kW AISI 316; primary DN40; filter 50 micron stainless. Fluid temperature setpoint 25 to 50 C, accuracy plus or minus 0.5 C. Sensors PT100 on supply and return, level, leak, conductivity, and pressure differential. Controller 7 inch HMI, Modbus TCP, BACnet/IP, SNMP, REST API. Power 230 V single phase, 1.5 kW. Empty weight 280 kg, filled weight 720 kg. Compatible fluids synthetic ester, PAO, mineral oil, and custom dielectrics on request. Operating ambient 5 to 35 C.
Application Scenarios
Typical deployments are medium-scale HPC clusters, AI training pods, render farms, and on-premise generative AI appliances. The system also suits Bitcoin and proof-of-work mining farms that need dense heat removal in locations where air cooling would require massive ductwork. Because the tank produces warm fluid return at 40 to 45 C, the heat can be reused for space heating or absorbed by a high-efficiency dry cooler without a chiller in most seasons. Additional use cases include VFX and animation rendering, oil and gas reservoir simulation, pharmaceutical molecular modeling, and university research clusters where fan noise would otherwise dominate the room.
Advantages and Features
Rack-scale form factor means the system drops into existing data hall power and network layouts without a raised-floor redesign. Integrated CDU eliminates a separate mechanical room and shortens commissioning. Dual baskets allow independent servicing: lift one basket while the other stays online. Warm-water return enables free cooling for most of the year, cutting cooling energy by 70 percent compared with chilled-water air cooling. The sealed bath eliminates dust and humidity concerns, extending hardware service life. Magnetic-drive pumps remove the shaft seal leak path.
Installation and Maintenance
Place the tank on a reinforced floor rated for 800 kg, anchor with four M12 bolts, connect primary DN40 flanges, and terminate power and network. Fill with dielectric fluid through the filtered port, run the pumps for an hour to vent, and load the servers. Maintenance: monthly level check, quarterly filter differential check, semi-annual fluid sample for acidity and moisture, annual heat exchanger coil inspection, and five-year seal replacement. KITOZER provides a training course for first-line service engineers. Recommended on-site spares include one pump cartridge, one filter element, and one lid gasket set.
Price
From $18,800/system. Contact +86 13922289957 for 500L immersion system pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com