Table of Contents
ToggleProduct Overview
The KITOZER single-phase immersion cooling tank is a sealed, fluid-filled enclosure designed to immerse GPU servers, storage arrays, and networking equipment directly in a dielectric coolant. Heat generated by the components is absorbed by the coolant, carried to a remote liquid-to-liquid heat exchanger, and rejected to facility chilled water or a dry cooler loop. Single-phase immersion eliminates fans, rear-door heat exchangers, and perforated tiles, cutting rack power consumption by up to 30 percent while enabling 50 to 100 kW per rack. The tank is delivered with sealed quick-disconnects, a lift-off lid, integrated pumps, and a level-monitoring controller.
The tank uses a recirculation loop that pumps coolant from the bottom of the bath through an external heat exchanger and back to the top, creating a gentle convective flow across the immersed components. This forced circulation prevents thermal stratification and keeps component temperatures within a few degrees of each other, even across a dense rack of GPU servers. The bath is covered by a sealed lid with a small breather vent, and a secondary containment tray under the tank catches any leak before it reaches the data hall floor.
Technical Specifications
Tank capacity 200 to 800 L depending on model, stainless steel 304 welded construction, 0.5 bar design pressure. Coolant: approved single-phase dielectric oil or synthetic ester, kinematic viscosity 10 to 20 cSt at 40 C, thermal conductivity 0.14 W per m-K. Internal racks support up to 40 servers in 2U or 4U form factor. Integrated circulation pump: one 750 W variable-speed pump per tank, optional N+1. Heat exchanger connection: DN40 flange to CDU or dry cooler. Controls: 7 inch HMI, fluid level, temperature, leak detection, Modbus TCP, dry contact alarms. Dimensions 1200 x 1200 x 1600 mm for 400 L model, weight empty 280 kg, CE, KITOZER, 5 year tank warranty.
Sensor suite includes fluid level switch, top and bottom bath temperature sensors, return temperature from heat exchanger, pump VFD feedback, and leak detection in the secondary tray. The HMI logs 180 days of 1-minute trend data. Alarm categories cover low fluid level, high bath temperature, pump fault, leak, and communication. The tank lid is hinged and supported by gas struts, allowing one-person opening for server insertion. The quick-disconnects are rated for 10,000 cycles and use flat-face poppets to prevent spill on disconnect.
Applications
Single-phase immersion is ideal for GPU mining and rendering racks, genome sequencing compute, storage nodes with high disk density, and telecommunications edge nodes where acoustic noise must be minimized. Typical users include cryptocurrency mining farms, media render farms, seismic exploration compute centers, and research HPC labs. Because the tank is fully sealed, it also suits offshore or dusty industrial environments where air-cooled racks would suffer accelerated fan and filter failure.
The method also fits locations where acoustic comfort matters, such as office-adjacent rendering suites, university computer labs, and broadcast media rooms. With no rack fans, the tank operates below 60 dB, comparable to a quiet office. Storage arrays with hundreds of disks benefit because the dielectric coolant dampens vibration and eliminates fan failure, extending drive life. Offshore and desert deployments benefit from sealed protection against salt air, dust, and humidity.
Key Advantages
Direct immersion removes fan power and hot-spot risk, lowering PUE from 1.5 or higher to near 1.05. Dielectric coolant protects electronics from dust, humidity, and corrosion, extending server hardware life. Sealed quick-disconnects allow server insertion and removal without draining the tank. Integrated leak detection and secondary containment tray prevent environmental release. The tank accepts standard 19 inch rack servers with minor gasket modifications, protecting existing hardware investment. Low acoustic output makes immersion rooms acceptable in office-adjacent locations.
Forced circulation eliminates thermal stratification, keeping all components within a few degrees. Synthetic ester coolant is biodegradable and environmentally friendly compared with mineral oils. The tank is compatible with most OEM servers after a simple gasket and fan removal. Quick-disconnect heat exchanger connections allow CDU service without draining the bath. The stainless steel welded construction resists corrosion for decades. Factory pressure-tested and leak-checked before shipment.
Installation and Maintenance
Place the tank on a level concrete pad with secondary containment berm. Connect DN40 supply and return to the CDU, route a 32 A single-phase supply, and fill with dielectric coolant to the marked level. Monthly: inspect fluid level, clarity, and temperature trend; test leak sensors. Quarterly: sample coolant for acid number and moisture content; top up as needed. Annually: inspect gaskets on the lid and quick-disconnects, and replace filter bags. Server insertion uses the provided lift frame and takes under five minutes per node, with no coolant spill.
Commissioning includes verifying pump rotation, bleeding air from the loop, setting bath temperature setpoint, and exercising alarm logic. After handover, baseline bath temperature at nominal load and compare during quarterly reviews. Recommended on-site spares: one pump cartridge, one filter bag, one lid gasket, and one O-ring kit. Coolant top-up uses the same dielectric fluid as the initial fill, and mixing different chemistries is not recommended. Dispose of used coolant through a licensed waste handler.
Price
From $18,500 per 400 L tank. Contact +86 13922289957 for immersion cooling system quotation.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com