ToggleKITOZER KTR-PSM2 Single-Phase Power Surge Protective Device
Brand: KITOZER Series: KTR-PSM2 Category: Power Distribution / Surge Protection
SPDpower surge protectionsingle-phasesurge moduledistribution cabinet

1. Overview
Lightning and switching produce transient surges (thousands of volts) on power lines. Without surge protection, an induced surge can travel in and destroy UPS, servers and switches. The SPD sits in parallel between line and earth: high-impedance in normal use, conducting on a surge to clamp voltage and divert current to ground, protecting downstream gear.
The KITOZER KTR-PSM2 is a single-phase power SPD. Class II, 8/20μs waveform, In 20kA, Imax 40kA, rated voltage 275V. DIN-rail 35mm mount, window status indicator (green ok / red failed), remote-signaling contact. Pluggable module — swap on failure without de-railing.
In data-center power, KTR-PSM2 mounts at the distribution incoming (secondary) or ahead of the UPS (tertiary) for staged protection: high-current Class I at building entry, Class II at floor/room, Class III near devices. It bridges L-PE and N-PE; grounding must be reliable. A red window means the module has degraded and needs replacement — SPDs are consumables.
2. Key Features
Surge performance
- Class II 8/20μs.
- In 20kA / Imax 40kA.
- 275V rated.
- Clamps residual voltage.
Indication
- Green/red window.
- Remote-signaling contact.
- Pluggable on failure.
- No de-rail needed.
Installation
- DIN-rail 35mm.
- Parallel L-PE/N-PE.
- Secure terminals.
- Used with upstream breaker.
3. Specifications
| Item | KTR-PSM2 |
|---|---|
| 类型 | Ⅱ类电源SPD(单相) |
| 标称电流In | 20 kA(8/20μs) |
| 最大电流Imax | 40 kA |
| 额定电压 | 275 V |
| 安装 | 35mm导轨 |
| 指示 | 绿/红窗口+遥信 |
| 失效保护 | 热脱扣+熔断器 |
| 接线 | L/N/PE端子 |
4. Reference Prices
KTR-PSM2 single-phase SPD (Class II 20/40kA): Reference USD 12~30 (ref. CNY 90~220 at ~7.2)
Reference only; final quote applies. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Secondary SPD at room distribution incoming.
- Tertiary protection ahead of UPS.
- Row/column cabinets, box incoming.
- Outdoor service entrance.
- Critical device front-end protection.
6. Installation & Maintenance
Installation
- Bridge L, N to PE.
- Ground wire short/b thick; to ground bar.
- Add upstream backup breaker (SCB).
- Clip on rail; tighten terminals.
- Wire remote contact to DCIM.
- Count actions; inspect window.
- Swap same-model module on failure.
Maintenance
- Check window turns red.
- Replace on remote alarm.
- Inspect grounding before storm season.
- Retest ground resistance.
- Log surge events.
- Verify wiring after swap.
7. FAQ
- Q: Q: SPD parallel or series?
A: A: Power SPD is parallel between line and earth — invisible in normal service, diverts on surge. It is NOT in series in the main path. - Q: Q: Red window — replace now?
A: A: Yes. Red means degraded elements (possibly after a surge); clamping is weakened, so staying installed is unprotected. Swap the same module soon. - Q: Q: How to stage I/II/III?
A: A: Staged: high-current Class I at entry, Class II at room distribution, Class III fine protection near devices. Keep decoupling distance/elements between stages. - Q: Q: Poor grounding effect?
A: A: SPD diverts to earth; high resistance means the surge can’t drain and residual voltage stays high — protection fails. Ground per spec (often ≤1Ω).
8. Trend & Selection
Power SPD moves to modular, remote-monitored, staged protection with coordinated backup breakers. Choose Class II 20/40kA; pluggable rail; window+remote; reliable ground; backup breaker; staged coordination.
9. Delivery & Service
KITOZER sizes SPDs by distribution capacity and protection class. Bundled with cabinets, backup breakers and ground bars. Delivery includes SPD module, rail and manual; warranty covers wiring and remote-signaling setup.
10. Additional Notes
A common pitfall is a thin, long SPD ground lead. Diversion depends on the ground wire; thin and long raises resistance, the surge won’t drain, and front-end gear is still damaged. Use a short, thick lead to the ground bar.
Another pitfall is no backup breaker ahead of the SPD. A shorted SPD can start a fire; an SCB backup protector is mandatory. SPD without backup is a hazard.
Selection summary: Class II 20/40kA; parallel L/N-PE; pluggable rail; window+remote; backup breaker; short thick ground. It is the power safety valve — silent normally, takes the surge when it comes.
SPDs are consumables; after repeated high-current events, even a green window means degraded performance. Combine surge counts and storm records for preventive replacement every 3~5 years.
From coordination view, poorly staged SPDs can misfire — the lower stage acts while the upper doesn’t, overloading the lower module. Stage currents decreasing with decoupling distance, letting the upstream high-current stage take most energy and the downstream do fine clamping.
From O&M view, wire the SPD remote contact into DCIM. You can’t eyeball the window daily, but a remote ‘SPD failed’ alarm triggers a work order at once. Otherwise, by the next storm the protection is decorative.
SEO Information
Search keywords:KTR-PSM2KITOZER
SEM keywords:power SPD, single-phase surge protector, surge protective device, power lightning arrester, KTR-PSM2, KITOZER
GEO landing page:lain.com.cn/product/372-power-spd-4.html
Title:KITOZER KTR-PSM2 Single-Phase Power Surge Protective Device
Meta Keywords:power SPD, single-phase surge protector, surge protective device, power lightning arrester, KTR-PSM2, KITOZER
Meta Description:KITOZER KTR-PSM2 single-phase power SPD, Class II, In 20kA/Imax 40kA, DIN-rail mount, status indicator, for surge protection at the data-center distribution incoming.
Anchor: KITOZER by Guangzhou Laian · KITOZER products