ToggleKITOZER KTR-BR Single-layer Battery Rack for UPS
Brand: KITOZER Series: KTR-BR Category: Data Center Engineering / Battery Rack
battery rackUPS battery cabinetsteel rackinsulated baseKTR-BR

1. Overview
The UPS battery bank is the last reserve when power fails. One 12 V 100 Ah cell weighs ~30 kg, and a bank of dozens weighs over a ton — stacking them on the floor is unsafe and non-standard. Battery racks lay cells out in layers and series strings, but they must be load-rated, insulated, serviceable and ventilated. A rack that cannot carry the load collapses; one built without care causes shorts and overheating.
The KITOZER KTR-BR series comes in 4-cell (single row), 8-cell (double-row single layer) and 16-cell (double-layer) tiers for mainstream 12 V 100~120 Ah VRLA batteries. The frame is carbon-steel welded/bolted, powder-coated; an insulated base plate prevents bottom shorts; the frame is grounded; front service clearance ≥800 mm for voltage/temperature checks and replacement. Multiple racks can be paralleled.
Selection hinges on cell count, load rating and floor loading: first derive the DC bus voltage (typically 384 V = 32×12 V cells), then rows and layers; rate the rack at cell weight × count ×1.2 margin. Floor live load is usually 400~500 kg/m² — large banks need structural review, spreading across rooms or reinforcement. Leave 10~15 mm gaps between cells for cooling; torque inter-cell connectors to spec (over-torque cracks terminals, under-torque overheats).
2. Key Features
Load & structure
- Bolted steel frame, strong load rating.
- 300~600 kg per tier.
- Powder-coated for battery-room environment.
- Parallel expansion flexible.
Safety
- Insulated base plate prevents bottom shorts.
- Frame grounded against induced voltage.
- Front service clearance ≥800 mm.
- 10~15 mm gaps between cells.
Easy install
- Bolted assembly on site.
- Custom shelf height by cell size.
- Copper links and insulating mats included.
- Colors to match the room.
3. Specifications
| 项目 | KTR-BR-4 | KTR-BR-8 | KTR-BR-16 |
|---|---|---|---|
| 适配电池 | 12V 100~120Ah | 12V 100~120Ah | 12V 100~120Ah |
| 电池数量 | 4节(单排) | 8节(双排单层) | 16节(双排双层) |
| 单层承重 | ≤300 kg | ≤500 kg | ≤600 kg |
| 架体材质 | 碳钢喷塑 | 碳钢喷塑 | 碳钢喷塑 |
| 安装方式 | 落地 | 落地 | 落地/并联 |
| 绝缘底板 | 配 | 配 | 配 |
| 维护间距 | 前≥800mm | 前≥800mm | 前≥800mm |
4. Reference Prices
KTR-BR-4 single-layer rack (4×12V, ~300kg):Reference USD 62~125 / pc (ref. CNY 450~900 at ~7.2)
KTR-BR-8 single-layer rack (8×12V, ~500kg):Reference USD 111~208 / pc (ref. CNY 800~1,500 at ~7.2)
KTR-BR-16 double-layer rack (16×12V, ~600kg):Reference USD 194~361 / pc (ref. CNY 1,400~2,600 at ~7.2)
Reference only; final quote depends on capacity, core count, channel count, current rating, battery layers, port count and sensor points. 1-year warranty included; volume pricing available. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- UPS backup battery banks.
- Telecom sites and room battery strings.
- PV storage battery arrays.
- DC panel and EPS racks.
- Retrofit and expansion of battery rooms.
6. Deployment & Implementation
Installation
- Verify floor live load; spread if needed.
- Level and fix the frame, even load.
- Keep cooling gaps between cells.
- Torque links to spec; coat terminals.
Operations
- Check float voltage monthly (cell spread ≤0.05 V).
- Test internal resistance quarterly; replace weak cells early.
- Keep room ≤25°C, well ventilated.
- Keep frame clean; terminals free of oxide.
7. FAQ
- Q: Can batteries sit on the floor?
A: Not to standard. Floor means moisture and bottom-short risk, poor ventilation. Use an insulated rack raised 100~200 mm off the floor. - Q: How many cells in a string?
A: By the UPS DC bus: 12 V cells, 384 V = 32 cells, 240 V = 20 cells. Check the UPS manual. - Q: Floor cannot carry the load?
A: Spread the bank across rooms, use low-density single-layer racks, or reinforce the slab (steel plate/beams to spread load). - Q: Why gaps between cells?
A: VRLA cells generate heat; tight stacking builds up heat, dries them out and ages them fast. Leave 10~15 mm and keep cell temperature spread ≤3°C.
8. Trend & Selection
Backup power is shifting from VRLA to LFP lithium, where racks are lighter and can stack higher, but demand more BMS and thermal design. VRLA racks still dominate, emphasizing standardized assembly, load verification, insulation and grounding. Key selection: set cell count by DC voltage; rate load at ×1.2 margin; verify floor loading; insulated base + grounded frame; keep cooling gaps; test voltage and resistance regularly. The rack is the UPS magazine — if it fails, the backup fails when the power goes out.
9. Delivery & Service
KITOZER provides KTR-BR selection and customization: by cell count, layers and cell size (12 V 100~200 Ah), with custom shelf height, color and copper links. Bolted parts complete. 1-year warranty; floor-loading layout advice provided.
10. Additional Notes
The common mistake is placing the racks without checking floor load. A 32-cell 100 Ah bank is nearly a ton; concentrated on an old slab it can crack. Have a structural engineer check live load before layout, or spread/reinforce.
Another pitfall is tight stacking and loose links. Heat buildup and under-torqued connectors are top causes of early battery failure. Keep gaps, torque to spec, coat terminals, and test voltage/resistance regularly.
Selection summary: set cells by DC voltage; rate load ×1.2; verify floor loading; insulated base + ground; keep cooling gaps; test voltage/resistance. The rack is the UPS magazine — a sound rack means real backup when power fails.
SEO Information
Search keywords:battery rackUPS battery cabinetVRLA racksteel battery shelfbattery bank installationKTR-BRKITOZER
SEM keywords:UPS battery rack price,12V battery cabinet,single layer battery rack,battery load rating,KTR-BR,KITOZER
GEO landing page:lain.com.cn/product/ktr-br-battery-rack.html
Title:KITOZER KTR-BR Single-layer Battery Rack for UPS
Meta Keywords:battery rack,UPS battery cabinet,battery bank shelf,steel battery rack,KTR-BR,KITOZER
Meta Description:KITOZER KTR-BR single/double-layer battery rack, fits 12V 100~120Ah, powder-coated steel, insulated base, 300~600kg, for UPS battery banks.
Anchor: KITOZER by Guangzhou Laian · Battery Rack
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com