KITOZER Smart Meter: Multi Function Panel Power Meter

Product Overview

KITOZER multi-function panel power meter is a 96x96mm panel-mounted instrument that measures a full suite of electrical parameters on a three-phase supply, including harmonics up to the 31st order, demand current, and THD. It is designed for the front of low-voltage switchboards, MCC panels, and data center power cubicles, where operators need at-a-glance visibility of incoming power quality. The meter communicates over Modbus RTU and supports up to four alarm relay outputs, allowing it to trigger external annunciators or BMS alarms when voltage, current, or THD exceeds set limits. The backlit LCD provides clear readability even in dimly lit electrical rooms.

Unlike a basic panel meter that only shows voltage and current, this device includes harmonic analysis and demand metering, which are essential in modern facilities with many electronic loads. The harmonic spectrum screen shows each harmonic amplitude as a bar chart, helping engineers identify whether distortion comes from 5th, 7th, or 11th order harmonics, each of which points to a different source. The demand current measurement tracks the highest 15-minute average current, supporting demand charge management on utility bills.

Technical Specifications

Rated voltage 3x230V/400V, rated current 5A via CT, frequency 50/60Hz. Measurements: voltage, current, active and reactive power, power factor, frequency, import and export kWh, demand current, THD voltage and current, harmonics 2nd to 31st. Accuracy class 0.5. Four alarm relay outputs 5A 250VAC. RS485 Modbus RTU. Pulse output. Panel cutout 92x92mm. Power supply 85V to 265VAC. Operating temperature minus 10C to plus 55C. CE, KITOZER brand, three year warranty.

Application Scenarios

This meter is installed on the main incomer of data center switchboards, industrial MCCs, commercial building main panels, and generator output panels. It is also used on the input side of UPS systems, active filters, and SVG units, where power quality visibility is essential for commissioning and troubleshooting. The harmonic measurement function is valuable in plants with variable frequency drives, LED lighting, and switching power supplies, because it helps engineers locate the source of voltage distortion. The alarm relays trigger remote alarms when THD exceeds the IEEE 519 limit.

Additional installations include hospital electrical rooms, university building main panels, and shopping mall switchboards. In each case, the operator needs both energy measurement and power quality visibility in one panel device. The demand current feature is valuable for factories that pay demand charges, because it helps them avoid exceeding their contracted demand. The Modbus RTU integration feeds the building management system with 1-second data, supporting real-time energy dashboards.

Advantages and Features

The meter replaces several standalone instruments (voltmeter, ammeter, power factor meter, harmonic analyzer) with one panel device, reducing panel cutouts and wiring. Harmonic and THD data give early warning of power quality problems before they cause equipment heating or nuisance tripping. Programmable alarm relays support local annunciation and BMS integration. The Modbus RTU interface feeds energy management systems with 1-second sampling data. The compact 96×96 size fits standard panel cutouts used by most switchboard builders.

The backlit LCD cycles through multiple display pages automatically, showing voltage, current, power, and harmonics without button presses. The alarm relays can be configured as normally open or normally closed, suiting different wiring conventions. The demand interval is adjustable from 5 to 60 minutes, matching the utility billing period. The meter stores energy totals for billing, and the pulse output supports hardwired counters. The three year warranty covers the meter and CT inputs.

Installation and Maintenance

Cut a 92x92mm opening in the panel door, insert the meter from the front, and secure with the rear mounting bracket. Connect voltage leads, CT secondaries, and auxiliary power according to the wiring diagram. Set the CT ratio, PT ratio, alarm thresholds, and Modbus address through the front menu. Verify measurements against a known reference meter. Maintenance is limited to annual terminal inspection and LCD contrast check. The meter has no moving parts and requires no scheduled calibration beyond the factory accuracy period.

During installation, keep CT secondary wires away from high-voltage conductors to avoid noise. Ground the CT secondary at one end. Set the alarm thresholds for THD at the IEEE 519 limit (typically 5 percent voltage THD). Wire the alarm relay outputs to the BMS annunciator and test each alarm. The front buttons are lockable, preventing accidental parameter changes. If the LCD contrast fades, it can be adjusted through the setup menu. The meter is powered directly from the measured voltage, so no separate control supply is needed, which simplifies wiring. The 0.5 accuracy class supports both energy monitoring and basic power quality compliance reporting.

Price

From $85/pc. Contact +86 13922289957 for panel meter pricing.