Table of Contents
ToggleProduct Overview
KITOZER three-phase DIN-rail smart meter is a compact energy measurement device designed for sub-metering in distribution boards, data center power panels, and tenant billing systems. The meter measures voltage, current, active and reactive power, power factor, frequency, and totalized kWh on a three-phase four-wire system. It mounts on a standard 35mm DIN rail and communicates over RS485 Modbus RTU, allowing it to be integrated into energy management, building automation, and data center monitoring platforms. The backlit LCD displays all key values on one screen, and the meter supports both direct connection up to 100A and current-transformer connection for higher currents.
The meter is designed for dense installation in distribution boxes, where space is limited but billing-grade accuracy is required. It records both import and export energy, making it suitable for solar self-consumption installations where surplus power flows back to the grid. The Modbus RTU interface allows dozens of meters to be daisy-chained on one twisted pair, reducing wiring in large buildings. The pulse output supports legacy energy counters that do not have digital communication.
Technical Specifications
Rated voltage 3x230V/400V, rated current 5A via CT or direct 100A, frequency 50/60Hz, accuracy class 1.0 for active energy, class 2.0 for reactive energy. Measurements include voltage per phase, current per phase, active power, reactive power, apparent power, power factor, frequency, import and export kWh, kvarh. LCD display 91x46mm. RS485 Modbus RTU up to 38400bps. Pulse output 1000imp/kWh. Power supply 85V to 265VAC. Operating temperature minus 25C to plus 70C. DIN rail 4 modules. CE, MID optional, KITOZER brand, three year warranty.
Application Scenarios
This meter is used for tenant sub-metering in commercial buildings, department-level energy allocation in factories, rack-row metering in data centers, and solar photovoltaic export monitoring. It is also popular in EV charger distribution panels, where each charger circuit requires independent energy measurement for billing. The DIN-rail form factor allows dense installation in standard distribution boxes, and the Modbus interface makes it easy to aggregate data into a central energy management system. Direct-connection models are used below 100A, while CT models are used for higher current feeders.
Additional installations include hotel floor distribution, school lab circuits, factory production line sub-meters, and shopping mall tenant panels. In each case, the operator needs to allocate energy cost to a department or tenant, and the meter provides the data. The import and export energy recording also supports solar self-consumption monitoring, where the meter tracks how much solar power is used on site and how much is exported. The pulse output feeds older building automation systems that only accept pulse counters.
Advantages and Features
The meter combines full three-phase power quality measurement in a 4-module DIN package, reducing panel space. The backlit LCD shows voltage, current, power, and energy without requiring a PC. Modbus RTU integration supports remote reading and alarm generation. The pulse output supports hardwired energy counters in legacy systems. The meter records both import and export energy, making it suitable for self-consumption solar installations. Low standby power and wide operating temperature range suit both indoor and outdoor cabinet use.
The wide power supply range means the meter works on any control supply from 85V to 265VAC, suiting global installations. The 4-module width allows up to 12 meters in a standard distribution box. The MID option supports legal-for-trade billing in markets that require it. The Modbus register map is documented, making integration straightforward. The three year warranty reflects the solid-state design with no moving parts.
Installation and Maintenance
Clip the meter onto a 35mm DIN rail. Connect voltage leads and CT secondary wires according to the terminal diagram. For CT models, install CTs on each phase with correct polarity and ensure the CT secondary is grounded at one end. Set the CT ratio, voltage ratio, and Modbus address through the front button menu. Verify kWh reading against a known load during commissioning. Maintenance is minimal; annual visual inspection and terminal torque check are sufficient. Keep wiring away from high-voltage busbars to avoid measurement noise.
During installation, daisy-chain the RS485 bus with a maximum of 32 meters per segment, and use a terminator at the far end. Set unique Modbus addresses for each meter. Verify the pulse output by checking the LED flashes on the front. For outdoor cabinet use, ensure the cabinet is ventilated to keep the meter within its temperature range. The meter has no scheduled calibration, but annual verification against a reference meter is recommended for billing applications. The compact 4-module width means a 12-way distribution box can hold up to 12 sub-meters, which is ideal for tenant billing in multi-tenant commercial buildings.
Price
From $45/pc. Contact +86 13922289957 for smart meter pricing and OEM.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com