ToggleProduct Overview
KITOZER 12 outlet switched smart PDU combines per-outlet control with three phase input for medium-density server racks. Each of the 12 IEC C13 or C19 outlets can be switched on or off remotely through the network, enabling operators to reboot unresponsive equipment, schedule power cycles, and enforce load shedding during peak demand. The PDU measures input voltage, current per phase, total power, energy, and temperature, and reports all values in real time. With group and sequence control, it can power up racks in a defined order to avoid inrush current spikes.
Remote outlet control is a game changer for teams managing distributed infrastructure. Instead of sending a technician to a remote site to cycle a frozen server, an operator can reboot the outlet from the web interface in seconds. This capability reduces mean time to recovery from hours to minutes. The three phase input means that even medium-density racks drawing 6 to 10kW can be powered from a single PDU, with balanced load across phases. Sequence-on logic ensures that when a rack comes back after a power outage, servers start in the correct order, preventing overload.
Technical Specifications
Input 200 to 415VAC three phase 50/60Hz, rated current 32A per phase. 12 outlets configurable as IEC C13 or C19, with phase distribution balanced at the factory. Per-outlet switching via electromagnetic relays, rated 16A each. Metering 1 percent accuracy, voltage per phase, current per phase, active power, kWh, power factor, and frequency. Temperature sensor on unit, optional 3 external probes. Communication 10/100/1000Mbps Ethernet, Modbus TCP, SNMP v3, HTTPS, and email alarms. Outlet grouping, sequence on/off, and scheduling. 1U rack mount. CE, UL, RoHS. KITOZER, 5 year warranty.
Relay life is rated at 100,000 operations under full load, ensuring years of service in normal use. The PDU supports user roles with read-only, operator, and admin levels, so junior staff can view data while senior staff approve control actions. It stores up to 5000 event logs with timestamps, including switching actions, alarms, and parameter changes. Sequence-on can be configured per outlet with adjustable delays from 1 to 60 seconds. The unit supports NTP, HTTPS, and SNMP v3 encryption. Operating temperature is 0 to 60 degrees Celsius, and the metal housing fits standard 19-inch rails.
Application Scenarios
This switched PDU is suited to colocation racks, private cloud rooms, and enterprise data centers where remote reboot capability saves travel time. It is also used in remote telecom huts and unmanned edge sites where on-site intervention is expensive. Operators use outlet-level control to isolate faulty equipment, enforce power budgets, and perform scheduled maintenance without sending technicians to the rack. Three phase input makes it ideal for racks drawing above 5kW.
Typical deployments include server racks with dual-cord equipment, storage arrays, network core switches, and GPU compute nodes. In colocation, customers request per-outlet control so they can reboot their own equipment without waiting for the provider. In edge sites, the PDU reduces truck rolls for frozen servers. In broadcast and production, it supports scheduled power cycling of non-critical equipment during peak demand. In industrial control, it allows safe isolation of a single device for maintenance while the rest of the rack stays online.
Advantages and Features
Outlet-level switching gives fine-grained control that monitored-only PDUs cannot match. The PDU supports user roles with permission levels, so junior operators can view data while senior staff approve control actions. Sequence-on configuration prevents all outlets from closing at once, limiting inrush current. The web interface displays a live power map with each outlet state, current, and alarm. Integration with DCIM platforms via Modbus TCP means that energy data flows into the same dashboard as cooling and space metrics. The unit also supports SNMP traps for third-party alarm systems.
Additional features include scheduling, which allows outlets to turn on and off at set times, useful for non-critical equipment. Group control lets operators switch a set of outlets together, such as all servers in a cluster. The PDU supports automated actions, such as cycling an outlet if current drops to zero for 60 seconds, which can recover unresponsive devices without human intervention. Firmware updates are signed and verified, ensuring that only KITOZER-approved code runs on the unit.
Installation and Maintenance Recommendations
Mount the PDU in the rack, connect the three phase input with correctly sized cable, and verify phase rotation before energizing. Configure IP settings, user accounts, and alarm thresholds before connecting servers. Label each outlet with the attached server name to make remote reboot actions safe. Test outlet switching during a maintenance window to confirm relays work as expected. Inspect relays every two years under load, and replace any outlet that fails to open or close. Keep firmware updated and maintain a backup of configuration.
For safe operation, ensure that the upstream breaker rating matches the PDU input rating, and that the earth conductor is connected to rack ground. Do not switch inductive loads such as motors or transformers through the outlet relays, as this can shorten relay life. Save a configuration backup after setup, and store it in a secure location. Test sequence-on logic during commissioning to confirm servers start in the correct order. KITOZER recommends annual relay test and firmware update, with a full configuration backup before any update.