ToggleProduct Overview
KITOZER 12 outlet switched smart PDU combines per-outlet control with three phase input for medium-density server racks. Each of the 12 IEC C13 or C19 outlets can be switched on or off remotely through the network, enabling operators to reboot unresponsive equipment, schedule power cycles, and enforce load shedding during peak demand. The PDU measures input voltage, current per phase, total power, energy, and temperature, and reports all values in real time. With group and sequence control, it can power up racks in a defined order to avoid inrush current spikes.
Technical Specifications
Input 200 to 415VAC three phase 50/60Hz, rated current 32A per phase. 12 outlets configurable as IEC C13 or C19, with phase distribution balanced at the factory. Per-outlet switching via electromagnetic relays, rated 16A each. Metering 1 percent accuracy, voltage per phase, current per phase, active power, kWh, power factor, and frequency. Temperature sensor on unit, optional 3 external probes. Communication 10/100/1000Mbps Ethernet, Modbus TCP, SNMP v3, HTTPS, and email alarms. Outlet grouping, sequence on/off, and scheduling. 1U rack mount. CE, UL, RoHS. KITOZER, 5 year warranty.
Application Scenarios
This switched PDU is suited to colocation racks, private cloud rooms, and enterprise data centers where remote reboot capability saves travel time. It is also used in remote telecom huts and unmanned edge sites where on-site intervention is expensive. Operators use outlet-level control to isolate faulty equipment, enforce power budgets, and perform scheduled maintenance without sending technicians to the rack. Three phase input makes it ideal for racks drawing above 5kW.
Advantages and Features
Outlet-level switching gives fine-grained control that monitored-only PDUs cannot match. The PDU supports user roles with permission levels, so junior operators can view data while senior staff approve control actions. Sequence-on configuration prevents all outlets from closing at once, limiting inrush current. The web interface displays a live power map with each outlet state, current, and alarm. Integration with DCIM platforms via Modbus TCP means that energy data flows into the same dashboard as cooling and space metrics. The unit also supports SNMP traps for third-party alarm systems.
Installation and Maintenance Recommendations
Mount the PDU in the rack, connect the three phase input with correctly sized cable, and verify phase rotation before energizing. Configure IP settings, user accounts, and alarm thresholds before connecting servers. Label each outlet with the attached server name to make remote reboot actions safe. Test outlet switching during a maintenance window to confirm relays work as expected. Inspect relays every two years under load, and replace any outlet that fails to open or close. Keep firmware current and maintain a backup of configuration.
Price
From $389 per unit including 12 switched outlets and three phase metering. Contact +86 13922289957 for switched PDU pricing.