KITOZER Smart PDU: 16 Outlet Metered Outlet Level

Product Overview

KITOZER 16 outlet metered smart PDU delivers outlet-level current measurement alongside total input metering, giving operators visibility into every socket in the rack. This level of detail is essential for chargeback, capacity planning, and fault detection in colocation and multi-tenant data centers. The unit measures current at each outlet, input voltage, input current, power, energy, and temperature, and pushes all data to a web dashboard or DCIM platform. Unlike switched models, the metered version has no relay per outlet, improving reliability for loads that must never be cycled remotely.

Technical Specifications

Input 200 to 240VAC single phase or 200 to 415VAC three phase, rated current 32A or 63A. 16 outlets in IEC C13 or mixed C13/C19. Per-outlet current measurement accuracy 2 percent, total input metering 1 percent. Temperature sensor on unit, optional 4 external probes. Communication 10/100/1000Mbps Ethernet, Modbus TCP, SNMP v3, HTTPS, email, and alarm relay. Web dashboard shows outlet-level current bars and alarm status. 1U or 0U vertical mount. CE, UL, RoHS. KITOZER, 5 year warranty.

Application Scenarios

The 16 outlet metered PDU is ideal for colocation cages where customers must be billed for actual energy consumption. It also suits enterprise data centers doing capacity planning, because operators can see which servers draw more power than expected. In high-density GPU racks, outlet-level data helps identify cards pulling abnormal current. In research labs and test environments, the PDU provides accurate energy measurement for equipment testing. Because there are no relays, the unit is preferred for medical and industrial control loads where remote switching is prohibited.

Advantages and Features

Outlet-level metering turns a passive distribution strip into a measurement instrument. Data can be exported as CSV for billing or analytics. The PDU supports threshold alarms per outlet, alerting operators before a server exceeds its planned budget. With no moving relays, reliability is high and mean time between failures is long. The web interface is intuitive, showing a power map with color-coded outlets. Multiple PDUs can be grouped under a single manager for large sites. KITOZER also provides an open API for integration into custom DCIM.

Installation and Maintenance Recommendations

Mount vertically in the rack for best outlet access, and label each outlet with the attached device. Wire the input according to local code, and confirm grounding continuity. Assign static IP and configure alarm thresholds based on planned load per outlet. Calibrate per-outlet measurement annually using a reference meter. Clean ventilation slots and inspect cables every six months. Keep spare PDUs on site for fast replacement if a unit fails.