Table of Contents
ToggleProduct Overview
KITOZER 16 outlet metered smart PDU delivers outlet-level current measurement alongside total input metering, giving operators visibility into every socket in the rack. This level of detail is essential for chargeback, capacity planning, and fault detection in colocation and multi-tenant data centers. The unit measures current at each outlet, input voltage, input current, power, energy, and temperature, and pushes all data to a web dashboard or DCIM platform. Unlike switched models, the metered version has no relay per outlet, improving reliability for loads that must never be cycled remotely.
Outlet-level metering transforms a passive distribution strip into a measurement instrument. Colocation providers use the data to bill each customer for actual energy consumption, rather than a flat rack fee. Enterprise teams use it to identify servers that draw more power than expected, which often signals failing hardware or misconfigured workloads. In high-density racks, outlet-level data helps spot imbalance between phases and overloaded circuits. Because there are no moving relays, the unit is preferred for medical, industrial, and research loads where remote switching is prohibited.
Technical Specifications
Input 200 to 240VAC single phase or 200 to 415VAC three phase, rated current 32A or 63A. 16 outlets in IEC C13 or mixed C13/C19. Per-outlet current measurement accuracy 2 percent, total input metering 1 percent. Temperature sensor on unit, optional 4 external probes. Communication 10/100/1000Mbps Ethernet, Modbus TCP, SNMP v3, HTTPS, email, and alarm relay. Web dashboard shows outlet-level current bars and alarm status. 1U or 0U vertical mount. CE, UL, RoHS. KITOZER, 5 year warranty.
Per-outlet measurement uses high-precision current transformers with 2 percent accuracy across the full range. Total input metering uses a 1 percent class meter, compliant with ANSI C12.20. The PDU stores up to 2 years of energy data at 15 minute intervals, and exports CSV via web or API. It supports NTP, HTTPS, and SNMP v3 encryption. User roles include read-only, operator, and admin. Operating temperature is 0 to 60 degrees Celsius. The metal housing fits standard 19-inch rails and can be mounted vertically or horizontally.
Application Scenarios
The 16 outlet metered PDU is ideal for colocation cages where customers must be billed for actual energy consumption. It also suits enterprise data centers doing capacity planning, because operators can see which servers draw more power than expected. In high-density GPU racks, outlet-level data helps identify cards pulling abnormal current. In research labs and test environments, the PDU provides accurate energy measurement for equipment testing. Because there are no relays, the unit is preferred for medical and industrial control loads where remote switching is prohibited.
Additional use cases include financial trading rooms, where accurate energy data supports capacity planning and compliance. In government and defense facilities, outlet-level monitoring helps detect unauthorized equipment connected to the rack. In education, it supports research projects that require precise energy measurement. In manufacturing, it monitors test rigs and production equipment. The PDU is also used in broadcast and AV racks, where accurate energy data helps plan for peak demand during live events.
Advantages and Features
Outlet-level metering turns a passive distribution strip into a measurement instrument. Data can be exported as CSV for billing or analytics. The PDU supports threshold alarms per outlet, alerting operators before a server exceeds its planned budget. With no moving relays, reliability is high and mean time between failures is long. The web interface is intuitive, showing a power map with color-coded outlets. Multiple PDUs can be grouped under a single manager for large sites. KITOZER also provides an open API for integration into custom DCIM.
Additional benefits include high accuracy, long data retention, and strong security. The unit supports HTTPS and SNMP v3, ensuring that measurement data is encrypted in transit. User roles prevent unauthorized configuration changes. Because there are no relays, the PDU draws less power and generates less heat than switched models. The 5 year warranty reflects confidence in the hardware. KITOZER provides a configuration tool that allows batch setup of multiple PDUs from a CSV file, reducing deployment time in large sites.
Installation and Maintenance Recommendations
Mount vertically in the rack for best outlet access, and label each outlet with the attached device. Wire the input according to local code, and confirm grounding continuity. Assign static IP and configure alarm thresholds based on planned load per outlet. Calibrate per-outlet measurement annually using a reference meter. Clean ventilation slots and inspect cables every six months. Keep spare PDUs on site for fast replacement if a unit fails.
For accurate billing data, ensure that the PDU clock is synchronized via NTP and that energy data is exported regularly. Do not connect inductive loads that can cause voltage spikes, as this may affect measurement accuracy. Save a configuration backup after setup. KITOZER recommends annual calibration and firmware update, with a full configuration backup before any update. Keep a log of outlet-to-device mapping, and update it whenever equipment is moved.