KITOZER 24 outlet switched and monitored smart PDU is the high-density model for large server racks and AI training clusters. It combines 24 IEC outlets with per-outlet switching, per-outlet current measurement, three phase input, and network management. Operators can reboot individual servers, measure energy per outlet, set load thresholds, and sequence rack power on startup. The PDU is designed for racks drawing 10kW to 20kW, where a basic strip would overload and a monitored-only unit would lack control.
High-density racks require a PDU that can both measure and control. As GPU and AI training nodes draw 5 to 10kW per rack, operators need real-time data to balance phases and detect abnormal current. The 24 outlet PDU provides this visibility in a single 0U vertical unit, saving rack space. Per-outlet switching allows automated recovery of unresponsive nodes, reducing downtime in training clusters where a single failed node can waste hours of compute time. Sequence-on logic ensures that all nodes come back in the correct order after a power outage.
Technical Specifications
Input 200 to 415VAC three phase 50/60Hz, rated current 63A per phase. 24 outlets configurable as C13, C19, or mixed, balanced across phases. Per-outlet relay switching 16A, per-outlet current measurement 2 percent. Total input metering 1 percent, voltage per phase, current per phase, active power, kWh, power factor. Temperature sensor on unit, optional 6 external probes. Communication 10/100/1000Mbps Ethernet, dual network ports for daisy chain, Modbus TCP, SNMP v3, HTTPS, email, alarm relay. Outlet grouping, sequence on/off, scheduling, and user roles. 0U vertical mount. CE, UL, RoHS. KITOZER, 5 year warranty.
Relay life is 100,000 operations under full load. The PDU stores up to 10,000 event logs and 2 years of energy data at 15 minute intervals. Dual network ports allow daisy chaining, so multiple PDUs in a row share a single network drop. It supports NTP, HTTPS, SNMP v3, and RADIUS authentication. User roles include read-only, operator, and admin. Sequence-on delays are adjustable from 1 to 60 seconds per outlet. Operating temperature is 0 to 60 degrees Celsius. The metal housing is designed for vertical mounting at the rear of the rack.
Application Scenarios
This PDU is deployed in hyperscale server racks, AI and GPU training clusters, high-density compute pods, and large storage arrays. It supports remote reboot of failed nodes without sending technicians to the rack. Colocation providers use it for multi-tenant racks where customers request per-outlet control. In edge sites with limited access, it reduces truck rolls. It is also used in broadcast studios and production rooms where equipment must be cycled on a schedule.
Typical deployments include GPU training racks with 8 to 16 nodes, high-density storage arrays, and network core switches. In cloud data centers, the PDU supports automated power management as workloads move between racks. In HPC environments, per-outlet data helps identify nodes with abnormal power draw, which often indicates hardware faults. In financial trading, it supports accurate energy measurement for compliance. The PDU is also used in government and defense facilities where remote control and monitoring are required for secure racks.
Advantages and Features
The combination of switching and metering at every outlet gives operators both control and insight. Sequence-on logic prevents inrush when an entire rack is powered up after maintenance. Dual network ports allow daisy chaining, reducing switch port count. User roles prevent accidental shutdown of critical equipment. The web dashboard shows a real-time power map with outlet states and currents. KITOZER firmware supports automated actions, such as cycling an outlet if current drops to zero. Energy data feeds into DCIM for capacity planning and chargeback.
Additional features include high relay life, long data retention, and strong security. The PDU supports HTTPS, SNMP v3, and RADIUS, ensuring that control commands are authenticated and encrypted. Automated actions can be configured to recover unresponsive nodes without human intervention. Group control lets operators switch a set of outlets together. The 5 year warranty reflects confidence in the hardware. KITOZER provides an open API for integration with cluster management software, allowing automated power actions in response to workload events.
Installation and Maintenance Recommendations
Mount vertically at the rear of the rack, and route input cable with appropriate strain relief. Wire three phase input to the correct terminals, and verify phase rotation. Configure network, users, and thresholds before connecting servers. Label outlets clearly and maintain a mapping document. Test switching sequence during commissioning. Inspect relays and contacts every two years, and replace any outlet with erratic behavior. Keep firmware updated and back up configuration files.
For safe operation, ensure that upstream breakers match the PDU input rating and that the earth conductor is connected. Do not switch inductive loads through the outlet relays. Save a configuration backup after setup. Test automated actions during a maintenance window to confirm they work as expected. KITOZER recommends annual relay test, calibration, and firmware update. Keep a spare PDU on site for fast replacement. Maintain an outlet-to-node mapping document, and update it whenever equipment is moved or replaced.