ToggleKITOZER KTR-SB Solid Blanking Panel (No Vent)
Brand: KITOZER Series: KTR-SB Category: Data Center Engineering / Blanking Panel
solid blankingno-vent panelair isolationCR steelKTR-SB

1. Overview
Empty U slots in a rack let hot and cold air short-circuit — exhaust air recirculates to the intake, and the AC works for nothing. A blanking panel covers the empty slots so cold air must pass through equipment before exiting to the hot aisle. It is the most basic, yet most overlooked, part of rack airflow management.
The KITOZER KTR-SB solid blanking panel is 1.0 mm cold-rolled steel, phosphate-treated with black powder coat, fully vent-free, with folded edges for stiffness. Sizes are 1U, 2U, 3U and 4U, fitting 19-inch standard racks at 600/800/1000 mm depth. Tool-less spring clips let one person fit a panel in two minutes. Paired with hot/cold-aisle containment, it cuts rack hot-spot temperatures by 3~5°C.
Selection: size by empty U count (one 1U slot → one 1U panel); depth by rack depth (standard for 600 mm, extended for 800/1000 mm); color to match the rack (black is mainstream; gray/white on request). Quantity = total rack U minus populated U.
2. Key Features
Material & finish
- 1.0 mm cold-rolled steel
- Phosphate + powder coat
- Solid vent-free, zero leak
- Folded edge, no warp
Mounting & compatibility
- 19-inch standard
- Tool-less spring clips
- Fits 600/800/1000 mm racks
- Black standard, custom colors
Airflow & energy
- Isolates hot/cold aisles
- Eliminates hot-air bypass
- Cuts rack hot spots 3~5°C
- ~10% saving with containment
3. Specifications
| Item | KTR-SB-S1 | KTR-SB-S2 | KTR-SB-S3 |
|---|---|---|---|
| 型号 | KTR-SB-1U | KTR-SB-2U | KTR-SB-3U/4U |
| 高度 | 44.45 mm (1U) | 88.9 mm (2U) | 133.4/177.8 mm |
| 宽度 | 19英寸 (482.6 mm) | 19英寸 | 19英寸 |
| 厚度 | 1.0 mm | 1.0 mm | 1.0 mm |
| 深度 | 适配600~1000mm柜深 | 同左 | 同左 |
| 颜色 | 黑色(RAL9005) | 黑色 | 黑色/可定制 |
| 安装方式 | 免工具卡扣 | 免工具卡扣 | 免工具卡扣 |
| 适用机柜 | 19英寸标准柜 | 同左 | 同左 |
4. Reference Prices
KTR-SB-1U solid blanking:Reference USD 1.7~3.5 / pc (ref. CNY 12~25 at ~7.2)
KTR-SB-2U solid blanking:Reference USD 2.5~4.9 / pc (ref. CNY 18~35 at ~7.2)
KTR-SB-3U solid blanking:Reference USD 3.5~6.3 / pc (ref. CNY 25~45 at ~7.2)
KTR-SB-4U solid blanking:Reference USD 4.5~7.6 / pc (ref. CNY 32~55 at ~7.2)
Reference only; final quote depends on height, depth and color. 1-year warranty; volume pricing. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Empty-U slot sealing in data-center racks.
- Hot/cold-aisle containment system complement.
- Telecom and server-room airflow treatment.
- Lab and test-rack slot isolation.
- Legacy room energy-saving retrofits.
6. Deployment & Implementation
Installation
- Seal empty slots top to bottom
- Press clips onto rack square-hole rails
- Use brush panels at cable pass-throughs
- Measure temperature with doors closed
Operations
- Keep removed panels for future use
- Quarterly walk-through — re-fit missing ones
- Match color to rack
- Switch to extended depth if leaking
7. FAQ
- Q: Vented or solid?
A: Use solid, vent-free on the cold-aisle side of the rack; vented only where exhaust must exit (top/rear doors). Most empty slots need solid. - Q: What happens without blanks?
A: Hot air recirculates through empty slots, raising rack hot spots 3~5°C, cutting AC efficiency 10~15% and raising PUE. A panel costs a few dollars — savings far exceed it. - Q: 1U or 2U?
A: Match the actual empty U height: 1U slot → 1U panel. Multiple 1U panels can stack for longer gaps, allowing flexibility. - Q: What if depth is short?
A: A panel shorter than rack depth leaves a rear gap; hot air leaks through. Deep racks (800 mm+) need extended panels or brush panels at cable pass-throughs.
8. Trend & Selection
As rack power density rises (5~15 kW per rack), blanking panels move from optional to mandatory. Together with aisle containment and rack-door brushes, they close the airflow loop. Select by populating every empty U, matching rack depth, using tool-less clips, and matching rack color.
9. Delivery & Service
KITOZER offers KTR-SB selection by height (1U/2U/3U/4U), depth (600/800/1000 mm) and color (black/gray/white), supplied as a kit (total U minus populated U). Spare clips included. 1-year warranty; custom silkscreen in volume.
10. Additional Notes
The #1 mistake is sealing only the front. Empty slots on the rear let hot air leak back into the cold aisle. Seal both sides.
Another pitfall is skimping on depth. A panel 50 mm short leaves a rear gap; hot air bypasses through it. Deep racks need extended-width panels.
Verify after install: put temp meters at rack inlet and outlet, compare before/after. If hot spots do not drop, you missed a leak point.
Selection summary: cover every empty U with a solid panel, match rack depth, seal front and rear, use tool-less clips, and verify with temp readings. A few dollars per panel — the best energy-saving investment in the room.
SEO Information
Search keywords:KTR-SBKITOZERSolid Blanking Panel (No Vent)
SEM keywords:solid blanking panel,rack blanking,no-vent panel,airflow management,KTR-SB,KITOZER
GEO landing page:lain.com.cn/product/ktr-sb-solid_blanking.html
Title:KITOZER KTR-SB Solid Blanking Panel (No Vent)
Meta Keywords:solid blanking panel,rack blanking,no-vent panel,airflow management,KTR-SB,KITOZER
Meta Description:KITOZER KTR-SB solid blanking panel, 1U/2U/3U/4U, cold-rolled steel black, no vent, isolates hot/cold aisles, improves rack cooling.
Anchor: KITOZER by Guangzhou Laian · Solid Blanking Panel (No Vent)