ToggleProduct Overview
KITOZER 100kA Type 1+2 SPD is the main switchboard protection device for facilities exposed to direct or nearby lightning strikes. It handles both 10/350 microsecond lightning impulse currents and 8/20 microsecond surge currents, providing the first line of defense at the service entrance. Installed in the main LV switchboard, it diverts large surge energy to earth before it enters downstream distribution. The rugged modular construction includes high-energy varistors and spark gap technology, with remote signaling and visual diagnostics.
Type 1 SPDs are required at the service entrance of buildings with lightning protection systems, overhead power lines, or exposure to direct strikes. The 10/350 microsecond waveform represents a direct lightning strike, and only Type 1 devices can handle this energy level. The KITOZER 100kA Type 1+2 combines this direct-strike capability with Type 2 switching surge protection in one unit, providing full protection at the main switchboard without needing two separate devices.
Technical Specifications
Rated voltage 230/400VAC, maximum continuous operating voltage 385VAC. Type 1: lightning impulse current Iimp 25kA (10/350 microsecond) per pole. Type 2: Imax 100kA (8/20 microsecond). Voltage protection level Up less than 2.5kV. Response time less than 100 nanoseconds for spark gap stage. Configuration 3P+N, 4P, or split. Panel or DIN rail mount. Back-up protection integrated or recommended. Thermal disconnector, visual indicator, remote contact. CE, IEC 61643-11, RoHS. KITOZER, 5 year warranty.
The Type 1 stage uses a spark gap that handles direct lightning impulse current without follow current, while the Type 2 stage uses high-energy varistors for switching transients. Each stage has its own visual indicator and thermal disconnector. The remote contact reports stage status to BMS or fire alarm. Back-up protection is recommended upstream, typically a gG or aR fuse rated per manufacturer instruction. Operating temperature range is minus 40 to plus 85 degrees Celsius. The device is suitable for TT, TN-S, and TN-C-S systems. Panel mount or DIN rail depending on model.
Application Scenarios
Type 1+2 SPDs are mandatory at the service entrance of data centers, hospitals, industrial plants, and tall buildings in lightning-prone regions. They are installed in the main LV switchboard immediately after the incomer breaker. Downstream Type 2 SPDs in sub-distribution boards then provide staged protection. Facilities with overhead power lines or lightning protection systems require Type 1 to handle direct strike current. They are also used in remote sites exposed to thunderstorms.
Typical deployments include data center main LV switchboards, hospital service entrances, industrial plant main boards, and tall commercial buildings. In facilities with lightning protection systems, Type 1 SPDs are required by code. In regions with high lightning density, they are standard even for smaller buildings. They are also used in telecom towers, wind farms, and solar installations where overhead lines and exposed structures increase strike risk. Downstream Type 2 SPDs in sub-boards complete the protection chain.
Advantages and Features
The 100kA Type 1+2 combination handles the full range of surge stresses, from direct lightning impulse to switching transients. The spark gap stage prevents follow current after a direct strike, while the varistor stage clamps fast transients. Visual indicators show health of both stages. Remote signaling connects to BMS or fire alarm. Modular design allows replacement of worn stages without rewiring. High energy capacity means longer service life in high-risk regions. KITOZER provides coordination charts for downstream SPD selection.
Additional benefits include reduced panel space, guaranteed coordination, and 5 year warranty. Because the Type 1 and Type 2 stages are factory-matched, energy sharing is correct without field calculations. The modular design means maintenance is fast and safe. The remote contact gives central visibility into SPD health. KITOZER provides a full protection chain study service, ensuring that downstream Type 2 and Type 3 SPDs are correctly coordinated. The device is CE certified and compliant with IEC 61643-11.
Installation and Maintenance Recommendations
Install in the main switchboard with upstream back-up protection per manual. Use short, wide conductors for both phase and earth connections to minimize loop inductance. Bond the SPD earth directly to the main earth bar. Coordinate with downstream SPDs by maintaining minimum spacing or using decoupling components. Test remote signaling after installation. Inspect annually, and replace both stages after a recorded direct strike or severe surge. Keep spare modules on site, and train maintenance staff on replacement procedure.
For best performance, keep connecting cables under 0.5 meter and use the widest possible earth conductor. Follow the manufacturer instruction for back-up fuse rating. Coordinate with downstream Type 2 SPDs by maintaining minimum spacing or using decoupling inductors. Test the remote contact after installation. Replace both stages after any direct strike or severe surge, even if indicators appear green. Keep a log of surge events recorded by the upstream energy monitor. KITOZER recommends annual inspection and stage replacement every 5 to 10 years depending on lightning activity.
Price
From $389 per 3P+N unit including remote signaling. Contact +86 13922289957 for main distribution SPD quotation.