KITOZER SPD: 100kA Type 1+2 Main Distribution

Product Overview

KITOZER 100kA Type 1+2 SPD is the main switchboard protection device for facilities exposed to direct or nearby lightning strikes. It handles both 10/350 microsecond lightning impulse currents and 8/20 microsecond surge currents, providing the first line of defense at the service entrance. Installed in the main LV switchboard, it diverts large surge energy to earth before it enters downstream distribution. The rugged modular construction includes high-energy varistors and spark gap technology, with remote signaling and visual diagnostics.

Technical Specifications

Rated voltage 230/400VAC, maximum continuous operating voltage 385VAC. Type 1: lightning impulse current Iimp 25kA (10/350 microsecond) per pole. Type 2: Imax 100kA (8/20 microsecond). Voltage protection level Up less than 2.5kV. Response time less than 100 nanoseconds for spark gap stage. Configuration 3P+N, 4P, or split. Panel or DIN rail mount. Back-up protection integrated or recommended. Thermal disconnector, visual indicator, remote contact. CE, IEC 61643-11, RoHS. KITOZER, 5 year warranty.

Application Scenarios

Type 1+2 SPDs are mandatory at the service entrance of data centers, hospitals, industrial plants, and tall buildings in lightning-prone regions. They are installed in the main LV switchboard immediately after the incomer breaker. Downstream Type 2 SPDs in sub-distribution boards then provide staged protection. Facilities with overhead power lines or lightning protection systems require Type 1 to handle direct strike current. They are also used in remote sites exposed to thunderstorms.

Advantages and Features

The 100kA Type 1+2 combination handles the full range of surge stresses, from direct lightning impulse to switching transients. The spark gap stage prevents follow current after a direct strike, while the varistor stage clamps fast transients. Visual indicators show health of both stages. Remote signaling connects to BMS or fire alarm. Modular design allows replacement of worn stages without rewiring. High energy capacity means longer service life in high-risk regions. KITOZER provides coordination charts for downstream SPD selection.

Installation and Maintenance Recommendations

Install in the main switchboard with upstream back-up protection per manual. Use short, wide conductors for both phase and earth connections to minimize loop inductance. Bond the SPD earth directly to the main earth bar. Coordinate with downstream SPDs by maintaining minimum spacing or using decoupling components. Test remote signaling after installation. Inspect annually, and replace both stages after a recorded direct strike or severe surge. Keep spare modules on site, and train maintenance staff on replacement procedure.