KITOZER SPD: 20kA Type 3 Surge Protector Single Phase

Product Overview

KITOZER 20kA Type 3 surge protective device is designed for final panel and equipment-level protection against residual surge energy. Installed close to sensitive loads such as server power supplies, network switches, and workstations, it clamps transient voltages to safe levels after upstream Type 1 and Type 2 SPDs have absorbed most of the energy. The modular plug-in design allows quick replacement of a worn surge module without rewiring the panel. A visual indicator shows module health, and optional remote signaling contacts send status to the building management system.

Type 3 SPDs are the last line of defense in a coordinated protection chain. Lightning surges enter the building through overhead lines, travel through the main switchboard where Type 1 and Type 2 devices absorb most of the energy, and then arrive at final panels as residual fast transients. Without Type 3 protection, these residual spikes can still damage switch-mode power supplies, reduce equipment life, and cause unexplained reboots. The KITOZER 20kA Type 3 device clamps these transients to a level that IT equipment can tolerate, completing the protection chain.

Technical Specifications

Rated voltage 230VAC single phase, maximum continuous operating voltage 275VAC. Nominal discharge current In 5kA (8/20 microsecond), maximum discharge current Imax 20kA per pole. Voltage protection level Up less than 1.5kV. Response time less than 25 nanoseconds. Pole configurations 1P, 1P+N, or 2P. DIN rail mount, modular width 18mm per pole. Thermal disconnection device inside each module, visual green/red indicator. Optional remote signaling contact. CE, IEC 61643-11, RoHS. KITOZER brand, 3 year warranty.

The SPD uses metal oxide varistor technology with thermal disconnection. When the varistor reaches end of life, an internal thermal mechanism disconnects it from the grid and triggers the red indicator, preventing fire risk. The remote signaling contact is a normally open dry contact that closes when the module fails. The device is designed for TT, TN-S, and TN-C-S systems. Operating temperature range is minus 40 to plus 85 degrees Celsius. Mounting is on standard 35mm DIN rail, and wiring terminals accept up to 25mm2 conductor. The module width is 18mm per pole, so a 1P+N unit occupies two modules.

Application Scenarios

Type 3 SPDs are typically installed in distribution boards near IT equipment, in industrial control panels, and at the input of sensitive instruments. They are used in office buildings, retail stores, residential server closets, and small workshops where lightning risk is moderate but equipment is valuable. Because they are compact DIN rail modules, they fit easily into existing consumer units and control cabinets. They are also used as secondary protection after larger Type 2 SPDs in the main switchboard.

Specific use cases include server room final distribution boards, industrial PLC panels, medical equipment input protection, and audiovisual racks in conference centers. In telecom sites, Type 3 SPDs protect modems and routers near customer premises. In education, they protect lab equipment and classroom AV systems. In banking, they protect teller workstations and network gear. The compact size means they can be retrofitted into existing panels without major rewiring, making them a cost-effective upgrade for older facilities.

Advantages and Features

The main advantage is equipment-level clamping. By the time surge energy reaches the final panel, upstream SPDs have reduced it, and the Type 3 device brings residual spikes to a level that switch-mode power supplies can tolerate. The plug-in module means maintenance is fast and does not require shutting down the panel for long. The visual indicator shows at a glance whether replacement is needed. Remote signaling allows central monitoring. Compact DIN rail mounting makes installation straightforward in most enclosures.

Additional benefits include low protection voltage, fast response time, and thermal disconnection safety. The 20kA Imax rating handles moderate surge events that Type 2 devices pass through. The module is replaceable without rewiring, and the base stays in the panel while the module is swapped. KITOZER modules are interchangeable within the same base, simplifying spares inventory. The device is CE certified and compliant with IEC 61643-11, ensuring acceptance in most commercial and industrial projects.

Installation and Maintenance Recommendations

Install the SPD as close as possible to the protected load, with short connecting cables under 0.5 meter to keep lead inductance low. Connect the protection earth conductor directly to the main earth bar without intermediate terminals. Follow the wiring diagram on the side of the device. After installation, test the visual indicator and remote contact. Inspect modules annually, and replace any unit showing red indicator or after a major surge event. Keep spare modules on site for fast swap-out.

For best performance, coordinate the Type 3 SPD with upstream Type 2 devices. If the distance between Type 2 and Type 3 is less than 10 meters, a decoupling inductor may be required to ensure proper energy sharing. Follow the manufacturer coordination chart. Do not install the SPD in damp or dusty environments without appropriate enclosure protection. Test the remote signaling contact after installation and after any module replacement. Keep a log of surge events recorded by upstream energy monitors, and replace Type 3 modules after any significant event.