KITOZER SPD: 40kA Type 2 Surge Arrester Three Phase

Product Overview

KITOZER 40kA Type 2 surge arrester is the standard protection device for sub-distribution boards in data centers, commercial buildings, and industrial plants. It absorbs surge energy induced by nearby lightning switching operations and discharges it safely to earth before reaching sensitive loads. The modular plug-in design allows hot replacement of worn modules, and the thermal disconnection device prevents fire risk when a module end of life is reached. A remote signaling contact connects the SPD to BMS or fire alarm systems for central monitoring.

Type 2 SPDs are the workhorse of surge protection. They are installed in every distribution board downstream of the main switchboard, protecting branch circuits that feed servers, lighting, HVAC, and sockets. The 40kA rating balances energy handling and cost, providing robust protection for most commercial loads without overspending. In regions with frequent thunderstorms, Type 2 protection is required to maintain equipment warranties and meet insurance requirements.

Technical Specifications

Rated voltage 230/400VAC three phase, maximum continuous operating voltage 385VAC L-N. Nominal discharge current In 20kA (8/20 microsecond), maximum discharge current Imax 40kA per pole. Voltage protection level Up less than 1.8kV. Response time less than 25 nanoseconds. Configurations 3P+N, 4P, or split. DIN rail mount. Thermal disconnector per module, visual indicator. Optional remote contact. CE, IEC 61643-11, RoHS. KITOZER, 5 year warranty.

The SPD uses metal oxide varistor technology with integrated thermal disconnection. Each module has a green/red visual indicator, and the optional remote contact reports status to BMS. The N module includes a gas discharge tube for neutral protection. Back-up protection is recommended upstream, typically a gG or aR fuse rated per the manufacturer instruction. Operating temperature range is minus 40 to plus 85 degrees Celsius. Mounting is on 35mm DIN rail, and terminals accept up to 35mm2 conductor. The device is suitable for TT, TN-S, and TN-C-S systems.

Application Scenarios

Type 2 SPDs are installed in distribution boards downstream of the main switchboard, protecting branch circuits feeding server rooms, lighting, HVAC, and sockets. They are standard in data center UPS input panels, building distribution, and industrial motor control panels. In regions with frequent thunderstorms, Type 2 protection is mandatory to guarantee equipment warranty. They are also used as the main SPD in small facilities where a Type 1 is not required.

Typical deployments include enterprise data center sub-boards, commercial building floor distribution, factory motor control panels, and hospital equipment circuits. In retail stores, they protect point-of-sale systems and back-office servers. In warehouses, they protect lighting and conveyor control panels. In telecom sites, they protect rectifiers and battery chargers. The 3P+N configuration is the most common, covering all three phases and neutral in a compact DIN rail package.

Advantages and Features

The 40kA rating balances energy handling and cost, providing robust protection for most commercial loads. Modules are replaceable without rewiring, and the visual indicator shows status at a glance. The integrated thermal disconnector isolates a failed module from the grid, preventing overheating. Remote signaling allows operators to be alerted before a module fails completely. Compact DIN rail form factor fits standard distribution boards. KITOZER modules are interchangeable within the same base.

Additional benefits include low protection voltage, fast response, and 5 year warranty. The plug-in module design means maintenance is fast and does not require shutting down the panel for long. The remote contact can be wired to a BMS or fire alarm panel, giving central visibility. KITOZER provides coordination charts for upstream and downstream SPD selection. The device is CE certified and compliant with IEC 61643-11, ensuring acceptance in most projects. KITOZER also offers a complete protection chain study service, helping engineers select the correct Type 1, Type 2, and Type 3 SPDs for each installation and ensuring proper energy coordination across all stages.

Installation and Maintenance Recommendations

Mount the SPD on DIN rail in the distribution board, connect upstream with a short cable and suitable back-up protection. Earth conductor must be as short and direct as possible, with cross-section per local code. Verify wiring configuration (TT, TN-S, TN-C-S) before energizing. Test remote signaling contact. Inspect modules annually, and replace after any major surge recorded by the upstream energy monitor. Keep spare modules on site.

For best performance, keep connecting cables under 0.5 meter and use wide, short earth conductors. Coordinate with upstream Type 1 SPDs by maintaining minimum spacing or using decoupling components. Follow the manufacturer instruction for back-up fuse rating. Test the visual indicator and remote contact after installation. Replace modules after any major surge, even if the indicator still shows green, because varistor energy capacity degrades. Keep a log of replacement dates and surge events.