ToggleProduct Overview
KITOZER 40kA Type 2 surge arrester is the standard protection device for sub-distribution boards in data centers, commercial buildings, and industrial plants. It absorbs surge energy induced by nearby lightning switching operations and discharges it safely to earth before reaching sensitive loads. The modular plug-in design allows hot replacement of worn modules, and the thermal disconnection device prevents fire risk when a module end of life is reached. A remote signaling contact connects the SPD to BMS or fire alarm systems for central monitoring.
Technical Specifications
Rated voltage 230/400VAC three phase, maximum continuous operating voltage 385VAC L-N. Nominal discharge current In 20kA (8/20 microsecond), maximum discharge current Imax 40kA per pole. Voltage protection level Up less than 1.8kV. Response time less than 25 nanoseconds. Configurations 3P+N, 4P, or split. DIN rail mount. Thermal disconnector per module, visual indicator. Optional remote contact. CE, IEC 61643-11, RoHS. KITOZER, 5 year warranty.
Application Scenarios
Type 2 SPDs are installed in distribution boards downstream of the main switchboard, protecting branch circuits feeding server rooms, lighting, HVAC, and sockets. They are standard in data center UPS input panels, building distribution, and industrial motor control panels. In regions with frequent thunderstorms, Type 2 protection is mandatory to guarantee equipment warranty. They are also used as the main SPD in small facilities where a Type 1 is not required.
Advantages and Features
The 40kA rating balances energy handling and cost, providing robust protection for most commercial loads. Modules are replaceable without rewiring, and the visual indicator shows status at a glance. The integrated thermal disconnector isolates a failed module from the grid, preventing overheating. Remote signaling allows operators to be alerted before a module fails completely. Compact DIN rail form factor fits standard distribution boards. KITOZER modules are interchangeable within the same base.
Installation and Maintenance Recommendations
Mount the SPD on DIN rail in the distribution board, connect upstream with a short cable and suitable back-up protection. Earth conductor must be as short and direct as possible, with cross-section per local code. Verify wiring configuration (TT, TN-S, TN-C-S) before energizing. Test remote signaling contact. Inspect modules annually, and replace after any major surge recorded by the upstream energy monitor. Keep spare modules on site.
Price
From $89 per 3P+N unit including remote contact. Contact +86 13922289957 for SPD quotation.