The KITOZER special wall color steel panel system is a high-performance wall solution tailor-made for data centers, computer rooms, server rooms and other sites with stringent environmental requirements. Developed based on modular design concepts, it integrates fire resistance, anti-static property, sound insulation, dust prevention, thermal insulation and electromagnetic shielding into one product. It builds a safe, reliable, clean and efficient operating environment for computer rooms and complies with China national standard GB 50174-2017 Code for Design of Data Centers and relevant industrial specifications.
Through multi-layer composite technology, the system combines premium metal panels with high-performance core materials to form an integrated wall material featuring structural integrity and diversified functions. It enables rapid installation and flexible assembly to drastically shorten computer room construction cycles and cut construction costs. With outstanding durability and maintainability, it serves as an ideal finishing option for modern computer room projects.
II. System Composition
The KITOZER special wall color steel panel system consists of core components listed below. Coordinated operation of all parts guarantees overall system performance:
表格
| Component Category | Core Parts | Function Description |
|---|---|---|
| Main Panel | KITOZER dedicated computer room color steel panel | Core wall component providing structural support and functional foundation with optional diversified core materials |
| Connection System | Tenon connection profiles, metal battens, internal/external corner fittings | Achieve tight splicing between panels to improve sealing, surface flatness and overall structural strength |
| Fixing System | Light-gauge steel keels (75-type/100-type), expansion bolts, self-tapping screws | Load-bearing wall framework securing color steel panels and fitting various building structures |
| Auxiliary System | Skirting boards, door/window wrapping profiles, sealing rubber strips | Optimize wall finishing details for better appearance while boosting dustproof and sound-insulating performance |
| Functional Accessories | Anti-static earthing terminals, shielding connecting sheets, thermal insulation cotton | Strengthen anti-static, electromagnetic shielding and thermal insulation functionalities of the whole system |
III. System Classification
Classified by functional requirements and application scenarios into three categories:
1. Classification by Core Material
表格
| Type | Core Material | Key Features | Applicable Scenarios |
|---|---|---|---|
| Gypsum Composite Panel | 12mm fire-resistant gypsum board | Class A1 fire rating, lightweight, excellent sound insulation, cost-effective | Ordinary computer rooms, network rooms, monitoring centers |
| Rock Wool Composite Panel | High-density rock wool (50kg/m³) | Class A1 fire rating, superior thermal insulation and sound insulation | Constant-temperature & constant-humidity computer rooms, IDC data centers, precision instrument labs |
| Magnesium Oxide Composite Panel | Magnesium oxide board | Fireproof, waterproof, high structural strength, impact resistance, mildew and bacteria resistant | Humid-environment computer rooms, medical equipment rooms, chemical control rooms |
| Aluminum Honeycomb Composite Panel | Aluminum honeycomb core | Ultra-light weight, high strength, superior flatness, outstanding shielding performance | High-end data centers, command centers, electromagnetic shielding rooms |
2. Classification by Functional Characteristics
- Anti-static Type: Conductive coating on surface; surface resistance ranging from 10⁶~10⁹Ω to static discharge and protect electronic equipment from electrostatic damage.
- Shielding Type: Combined metal faceplate, shielding core and conductive connection components; shielding efficiency ≥80dB within 30~3000MHz to meet EMC specifications.
- Cleanroom Type: Dense and smooth surface resistant to dust accumulation with easy cleaning, complying with ISO 14644 cleanliness standards for dust-free workshops and rooms.
- Energy-saving Type: High-performance thermal core with thermal conductivity ≤0.04W/(m·K) to reduce air-conditioning power consumption of computer rooms.
3. Classification by Installation Method
- Hidden Tenon Installation: U-bottom & V-groove edge design for invisible panel seams with premium tightness and aesthetic appearance.
- Exposed Batten Installation: Fixed via independent metal cover battens with strong three-dimensional effect and low precision requirement for panel edge processing.
- Keel Embedded Installation: Panels inserted into light steel keel frames for stable structure, suitable for large-area wall construction.
IV. System Configuration List (Brand: KITOZER)
表格
| No. | Product Name | Specification & Model | Brand | Unit | Remarks |
|---|---|---|---|---|---|
| Main Materials | |||||
| 1 | Gypsum composite color steel panel for computer room | KT-ZS-760H, 900mm×3000mm×75mm, 0.6mm hot-dip galvanized steel sheet +12mm fireproof gypsum board | KITOZER | ㎡ | Standard size; customized non-standard sizes available |
| 2 | Rock wool composite color steel panel for computer room | KT-YM-1200V,1200mm×2800mm×100mm,0.6mm aluzinc steel sheet+100mm rock wool | KITOZER | ㎡ | Thermal insulation type, Class A1 non-combustible |
| 3 | Magnesium oxide composite color steel panel for computer room | KT-BM-950Q,950mm×2500mm×75mm,0.6mm hot-dip galvanized steel sheet+12mm magnesium oxide board | KITOZER | ㎡ | Waterproof & moisture-proof for humid environments |
| Connection & Fixing System | |||||
| 4 | Tenon connecting profile | KT-LJ-01, compatible with 75mm-thick panels | KITOZER | m | Special for panel joint connection |
| 5 | Metal batten | KT-YT-02, 12mm width, aluminum alloy | KITOZER | m | For exposed mounting installation |
| 6 | Internal & external corner fitting | KT-YJ-03, aluminum alloy, fits 75/100mm panel thickness | KITOZER | pc | Wall corner finishing |
| 7 | Light-gauge steel keel | KT-LG-75,75×50×0.6mm, hot-dip galvanized | KITOZER | m | Wall load-bearing framework |
| 8 | Expansion bolt | M8×80mm, stainless steel | KITOZER | set | Keel fixation |
| 9 | Self-tapping screw | ST5.5×25mm, galvanized with waterproof washer | KITOZER | pc | Fasten panels onto keels |
| Auxiliary System | |||||
| 10 | Skirting board | KT-TX-100,100mm height, aluminum alloy | KITOZER | m | Bottom wall decoration and protection |
| 11 | Door & window wrapping profile | KT-BB-01, custom dimension | KITOZER | set | Edge finishing around doors and windows |
| 12 | Sealing rubber strip | KT-MJ-02, EPDM rubber | KITOZER | m | Enhance sealing, dustproof and sound insulation |
| Functional Accessories | |||||
| 13 | Anti-static earthing terminal | KT-JD-01, copper material | KITOZER | pc | Earthing for anti-static system |
| 14 | Shielding connecting sheet | KT-PB-03, stainless steel | KITOZER | pc | Joint connection for shielding panels |
| 15 | Thermal insulation cotton | KT-BW-04,50mm-thick glass wool | KITOZER | ㎡ | Optional accessory for improved thermal insulation |
V. System Schematic Diagram
Installation Schematic of KITOZER Special Wall Color Steel Panel System
plaintext
┌─────────────────────────────────────┐
│ Main building structure (Concrete/Brick Wall) │
└───────────┬─────────────────────────┘
▼
┌─────────────────────────────────────┐
│ Expansion bolt fixing points │
└───────────┬─────────────────────────┘
▼
┌─────────────────────────────────────┐
│ Light-gauge steel keel frame(75/100-type)│
└───────────┬─────────────────────────┘
▼
┌─────────────────────────────────────┐
│ Self-tapping screw fixation │
└───────────┬─────────────────────────┘
▼
┌─────────────────────────────────────┐
│ KITOZER dedicated color steel panel │
│ (Metal face + core + backing layer)│
└───────────┬─────────────────────────┘
▼
┌─────────────────────────────────────┐
│ Tenon joint / Metal fixing batten │
└───────────┬─────────────────────────┘
▼
┌─────────────────────────────────────┐
│ Corner finishing + skirting installation│
└───────────┬─────────────────────────┘
▼
┌─────────────────────────────────────┐
│ Optional anti-static earthing connection│
└─────────────────────────────────────┘
System Working Principle
- The main building structure serves as installation base; light steel keel frames are fixed via expansion bolts.
- KITOZER color steel panels are fastened to keels with self-tapping screws; panels are closely connected via tenon joints or metal battens.
- Corner fittings and skirting complete wall finishing; sealing strips improve tightness to reduce dust ingress and noise transmission.
- Anti-static panels connect to the computer room’s earthing system via earthing terminals to discharge static electricity and safeguard electronic devices.
- Shielding panels form continuous conductive paths by shielding connection sheets to realize electromagnetic shielding performance.
VI. Product Technical Parameters
1. General Technical Specifications for Full Range KITOZER Computer Room Color Steel Panels
表格
| Parameter Item | Technical Index | Testing Standard |
|---|---|---|
| Face Sheet Material | 0.6mm hot-dip galvanized/aluzinc steel sheet, double-side zinc coating ≥180g/m² | GB/T 12754-2006 |
| Coating Property | Hardened polyester conductive paint, coating thickness≥25μm, pencil hardness≥2H | GB/T 13448-2006 |
| Fire Rating | Class A1 non-combustible; furnace temperature rise ≤4℃, mass loss ≤50%, zero sustained combustion time | GB 8624-2012 |
| Anti-static Performance | Surface resistance:10⁶~10⁹Ω; earthing resistance ≤1Ω | SJ/T 10694-2006 |
| Sound Insulation | Sound reduction ≥45dB@500Hz | GB/T 50121-2005 |
| Environmental Performance | Formaldehyde emission ≤0.1mg/L, E0 grade | GB 18585-2020 |
| Impact Resistance | No crack or obvious deformation under 10J impact | GB/T 1451-2005 |
| Weather Resistance | Salt spray resistance ≥1000h, damp heat resistance ≥500h | GB/T 1771-2007 |
2. Parameter Comparison of Different Core Materials
表格
| Core Material | Thermal Conductivity(W/(m·K)) | Density(kg/m³) | Flexural Strength(MPa) | Waterproof Performance | Applicable Environment |
|---|---|---|---|---|---|
| Gypsum Board | ≤0.16 | 850~950 | ≥10 | Average | Dry ambient & regular computer rooms |
| Rock Wool | ≤0.04 | 40~60 | ≥8 | Good | Constant temperature & humidity rooms with high insulation needs |
| Magnesium Oxide Board | ≤0.12 | 900~1000 | ≥15 | Excellent | High-humidity & waterproof required spaces |
| Aluminum Honeycomb | ≤0.06 | 30~50 | ≥12 | Good | Lightweight required & electromagnetic shielding rooms |
3. Special Functional Parameters (Anti-static & Shielding Type)
表格
| Parameter Item | Anti-static Type | Shielding Type | Testing Standard |
|---|---|---|---|
| Anti-static Property | Surface resistance:10⁶~10⁹Ω, charge decay time ≤2s | – | SJ/T 10694-2006 |
| Shielding Efficiency | – | ≥80dB within 30~3000MHz | GB/T 30142-2013 |
| Earthing Resistance | ≤1Ω | ≤0.5Ω | GB 50169-2016 |
VII. Application Scope
Thanks to superior comprehensive performance, KITOZER color steel panel system is widely used in the following fields:
1. Data Centers & Computer Rooms
- Financial institution data centers (banks, securities, insurance companies)
- IDC computer rooms for internet enterprises
- E-government computer rooms of government departments
- Dispatching center rooms for energy industries
2. Telecommunication & Network Infrastructure
- Core machine rooms for telecom operators
- 5G base station equipment rooms
- Network switching centers
- Cloud computing data centers
3. Special-purpose Computer Rooms
- Medical imaging centers (CT, MRI, DR equipment rooms)
- Precision instrument laboratories
- Aerospace equipment control rooms
- Industrial automatic control centers
4. Other Application Scenarios
- Clean workshops for electronics, pharmaceutical and food industries
- Command centers (fire protection, public security, traffic management)
- Confidential information machine rooms
- Inner wall of modular data center containers
VIII. Product Advantages
Compared with conventional wall materials, KITOZER wall panel system features prominent merits as below:
1. High Safety with Outstanding Fire Resistance
- Class A1 non-combustible rating complying with GB 8624-2012 to inhibit flame spread and protect onsite equipment.
- Low-smoke zero-halogen formulation releases no toxic gas during combustion for safe personnel evacuation and equipment protection.
- Built-in anti-static structure eliminates static discharge damage to electronic equipment and prevents data loss.
2. High Energy Efficiency to Cut Operating Costs
- Low thermal conductivity core reduces heat exchange and lowers air-conditioner power consumption by over 30%.
- Tight tenon connection minimizes air infiltration and stabilizes constant-temperature & constant-humidity environment to improve AC efficiency.
- Lightweight structure reduces building load and foundation construction expenditure.
3. Dust-free Cleanliness Meeting Strict Cleanroom Standards
- Dense smooth surface prevents dust buildup to reduce equipment failure rate and maintenance workload.
- Near-seamless splicing eliminates dust accumulation gaps for easy daily cleaning.
- Optional antibacterial coating restrains germ growth for medical and hygienic applications.
4. Fast Installation to Shorten Construction Period
- Pre-fabricated modular design cuts site construction duration by over 50%.
- Dry construction eliminates wet mortar work and avoids weather-related construction delays & safety hazards.
- Flexible on-site cutting and combination adapt to irregular space layouts.
5. All-in-one Multifunctional Integrated Solution
- Integrates fireproofing, anti-static, sound insulation, thermal insulation and shielding into one panel to reduce raw material varieties.
- Customizable dimension, color and core material per personalized project requirements.
- Complete matching connection & fixing accessories guarantee reliable overall installation quality.
6. Long Service Life with Low Long-term Maintenance Cost
- High-performance surface coating with ≥20-year service life and outstanding anti-aging performance to reduce replacement frequency.
- High-strength composite structure resists physical impact and deformation.
- Dust-resistant surface simplifies daily cleaning and minimizes routine maintenance expense.
IX. Tender Spec Parameters for Bidding Control
Below are controllable technical parameters for bidding document compilation of KITOZER computer room wall panel system:
1. Core Technical Specifications
- Product definition: Metal sandwich panel dedicated for computer room, brand KITOZER with original manufacturer authorization certificate mandatory.
- Face sheet: ≥0.6mm hot-dip galvanized/aluzinc steel sheet with double-side zinc coating ≥180g/m² per GB/T 12754-2006.
- Core requirements:
- Gypsum composite panel:12mm fireproof gypsum board conforming to GB/T 9775-2008
- Rock wool composite panel:≥50mm high-density rock wool (≥50kg/m³), thermal conductivity ≤0.04W/(m·K), complying with GB/T 11835-2016
- Fire performance: Class A1 non-combustible per GB 8624-2012; third-party authoritative inspection report required.
- Anti-static property: Surface resistance 10⁶~10⁹Ω, charge decay ≤2s per SJ/T 10694-2006 with valid test report.
- Sound insulation: Sound insulation ≥45dB@500Hz per GB/T 50121-2005.
- Coating index: Hardened polyester paint, film thickness ≥25μm, pencil hardness ≥2H, salt spray resistance ≥1000h with test certificate provided.
2. Installation & Connection Specifications
- Joint type: Tenon or batten installation with seam clearance ≤0.5mm for tight panel assembly.
- Fixing accessories: Complete set of hot-dip galvanized 75/100-type keels, expansion bolts and self-tapping screws with superior anti-corrosion capability.
- Corner treatment: Dedicated aluminum corner fittings to ensure flat tight corner sealing.
- Earthing system: Anti-static panels equipped with original copper earthing terminals; earthing resistance ≤1Ω complying with GB 50169-2016.
3. Quality & After-sale Service Requirements
- Product warranty: Minimum 5-year factory warranty with official warranty letter from manufacturer.
- Certification: Authorized third-party test reports covering fire resistance, anti-static and environmental indicators.
- Delivery lead time: ≤15 working days; ≤20 working days for customized non-standard products.
- Installation service: Professional construction team; ≤3 working days installation for every 100㎡ wall area.
- After-sales support: 24-hour service response, on-site troubleshooting within 48 hours and lifelong technical consultation.
X. Customized Solutions for Different Computer Room Types
1. Regular Office Server & Network Room Solution
Applicable Scenarios: Enterprise server rooms, network labs, general monitoring centers
Core Configuration:
- Main panel: KITOZER KT-ZS-760H gypsum composite panel (0.6mm galvanized steel +12mm fire gypsum core)
- Connection: Hidden tenon joint + dedicated corner fittings
- Fixing:75-type hot-dip galvanized keels + expansion bolts
- Auxiliary parts: Aluminum skirting, door/window wrapping, EPDM sealing strips
Features: Class A1 fire rating, stable anti-static property, cost-effective with easy installation; smooth dustproof surface for regular computer room maintenance.
2. High-density Large-scale IDC Data Center Solution
Applicable Scenarios: Financial core data center, large cloud computing & IDC machine rooms
Core Configuration:
- Main panel: KITOZER KT-YM-1200V 100mm rock wool composite aluzinc panel
- Connection: Tenon joint + stainless steel shielding connecting sheets
- Fixing:100-type reinforced keels + heavy-duty stainless expansion bolts
- Auxiliary: Anti-static skirting, door wrapping, additional glass wool insulation and full shielding earthing system
Features: Class A1 fireproof, superior thermal insulation reducing air conditioning cost; ≥80dB shielding efficiency to eliminate electromagnetic interference; robust structure suitable for high-density cabinet layout.
3. Medical Hospital Imaging Center Solution
Applicable Scenarios: Hospital CT/MRI/DR medical equipment rooms
Core Configuration:
- Main panel: KITOZER KT-BM-950Q magnesium oxide waterproof composite panel
- Connection: Exposed metal batten mounting + customized special corner sealing
- Fixing:75-type galvanized keels + full stainless steel expansion bolts
- Auxiliary: Waterproof skirting, antibacterial surface coating and high-density sealing adhesive strips
Features: Excellent moisture-proof & mildew-proof for high-humidity hospital environment; Class A1 fire compliance for medical building codes; antibacterial finish convenient for regular disinfection cleaning to avoid cross-contamination.
4. Electromagnetic Shielding Confidential Computer Room Solution
Applicable Scenarios: Military command rooms, confidential information center, aerospace control lab
Core Configuration:
- Main panel: KITOZER KT-PB-1200P dedicated shielding panel (0.8mm aluzinc + shielding core + embedded copper mesh)
- Connection: Conductive shielding tenon profile + shielding connection pieces + conductive rubber strips
- Fixing:100-type heavy keels + integral copper earthing busbar
- Auxiliary: Shielded skirting, full shielding treatment for all door/window peripherals and complete integrated earthing network
Features: ≥100dB shielding efficiency within 30~1000MHz complying with GJB 151B-2013; full-enclosed shielding wall/ceiling/door/window system with reliable anti-static & Class A1 fire performance.
XI. Real Project Application Cases
Case 1: Head Office Data Center of National Commercial Bank
Project Overview: Newly-built banking headquarters data center with total construction area of 5000㎡, including host equipment room, network center and monitoring control room with strict requirements for fire prevention, anti-static, sound insulation and electromagnetic shielding.
Adopted Solution:
- KITOZER KT-YM-1200V 100mm rock wool composite color steel panels with Class A1 fire and thermal insulation property applied for main wall construction.
- Full hidden tenon splicing to realize seamless tight wall surface.
- Complete dedicated copper earthing network with overall grounding resistance ≤0.5Ω for static elimination.
- Shield-grade panels installed in core host room achieving ≥80dB electromagnetic shielding effect. Project Outcome:
- Construction cycle shortened by 40% vs traditional brick wall construction with drastically reduced labor and material cost.
- Annual air-conditioning power consumption cut by 35% to lower long-term operational expenditure.
- Equipment failure rate reduced by 60% after eliminating static and dust-related malfunctions; project passed national financial industry data center safety certification with favorable customer feedback.
Case 2: Grade-A Tertiary Hospital Medical Imaging Center
Project Overview: New imaging department including CT, MRI and DR rooms covering 1200㎡, requiring waterproof, antibacterial, fireproof and eco-friendly wall materials under high indoor humidity.
Adopted Solution:
- KITOZER KT-BM-950Q magnesium oxide waterproof composite panels with customized antibacterial top coating.
- Optimized sealed corner construction to reduce scattered radiation leakage from medical equipment.
- Full stainless steel skirting and door wrapping for corrosion resistance in humid medical environment. Project Outcome: Zero wall dampness or mildew under long-term high-humidity hospital conditions; passed medical environment cleanliness certification; easy daily disinfection and cleaning effectively reducing hospital cross-infection risk; fast-track construction without interruption to hospital daily medical service.
Case3: Large Internet Enterprise Cloud Computing Data Center
Project Overview: 10,000㎡ modular cloud computing data center consisting of multiple high-density server zones with strict requirements for rapid construction, energy saving and environmental protection.
Adopted Solution: Mixed specification layout with KT-ZS-760H gypsum composite panels for auxiliary rooms and KT-YM-1200V rock wool panels for core equipment areas; full dry modular prefabricated installation with 75-type standard keel and tenon connection system.
Project Outcome: Whole project completed three months ahead of schedule to support early business launch; annual electricity saving over millions RMB with 40% lower air conditioning consumption; obtained green building certification and excellent structural anti-seismic performance for long-term stable data center operation.
XII. SEO Keywords & Tags
Core Search Keywords
Computer room dedicated wall color steel panel, KITOZER computer room color steel plate, computer room decoration solution, data center wall material, fireproof anti-static color steel panel, rock wool composite panel, gypsum composite wall panel, magnesium oxide composite board, tenon-mounted color steel panel, medical machine room wall material, shielding room color steel panel, data center decoration plan
SEO Optimized Long-tail Keywords
Computer room color steel panel brand, dedicated panel unit price, construction scheme & technical parameter, fire rating & anti-static index, sound insulation performance, medical & shielding room wall solution, tender specification for KITOZER panel
Hashtag Tags
#ComputerRoomPanel #DataCenterConstruction #FireproofAntiStatic #KITOZER #ServerRoomDecoration #ShieldingRoom #ModularDataCenter #EnergySavingConstruction #CleanRoomEngineering