KITOZER
KITOZER

KITOZER Stainless Steel Piping: DN20 316L Hardline

System Integration Notes

When selecting KITOZER piping for a cooling loop, consider the coolant chemistry, pressure rating, and installation method. Stainless steel tubing is suitable for deionized water and high-purity loops, while copper and CuNi tubing are used in water-glycol and seawater applications. Plan for thermal expansion with loop offsets or expansion joints. Support tubing at intervals specified by the industry standard, and allow for movement at bends. After installation, pressure test the loop at 1.5 times working pressure before commissioning. Flush thoroughly to remove welding slag, Teflon tape fragments, and manufacturing residue. KITOZER recommends documenting each joint location and installation date for future reference. Inspect welded and brazed joints annually for signs of corrosion or weeping. Use compatible fittings to avoid galvanic corrosion between dissimilar metals.

Best Practices

Long-term piping reliability depends on disciplined installation practices. Before installation, inspect each tube length for internal contamination, and cap open ends at all times. During fabrication, deburr tube ends thoroughly to avoid flow disturbances. After welding, passivate the joint with citric acid or nitric acid treatment to restore the passive oxide layer. During pressure testing, use water, not air, and follow a staged pressure ramp. After the test, flush the loop to remove test debris. KITOZER recommends installing permanent pressure test ports at strategic points, so that future tests can be done without temporary fittings. Inspect piping annually, focusing on joints, hangers, and areas near pumps and valves where vibration is highest. Replace any hanger that shows deformation. Insulate piping in humid spaces to prevent condensation. Keep a record of all joint locations and repair history.

Price

From $28/meter. Contact +86 13922289957 for DN20 316L tubing pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

The KITOZER DN20 316L stainless steel hardline piping is a precision tube solution for primary and secondary liquid cooling loops where corrosion resistance and long service life are critical. Supplied in 6-meter lengths with electropolished interior, the tubing is suitable for deionized water, high-purity glycol solutions, and dielectric fluids. The 316L material resists pitting and crevice corrosion in chloride-containing environments, making it the standard choice for data center primary loops and semiconductor fab cooling. KITOZER supplies tubing with a mill certificate and passivation to ASTM A967.

Product Overview

316L stainless steel tubing is the gold standard for high-purity cooling loops. The low-carbon 316L composition resists intergranular corrosion after welding, making it suitable for welded primary loop installations. The tubing is drawn to tight OD and wall thickness tolerances, ensuring compatibility with compression fittings, press fittings, and orbital welding. The electropolished interior reduces biofilm growth and fouling over decades of service. DN20 is the typical size for row-level secondary loops serving multiple racks. The tubing can be bent, welded, or press-fit depending on the installation method. KITOZER supplies tubing in 6-meter lengths, cut to order, with protective end caps.

Technical Specifications

Material: 316L stainless steel. OD: 25.4 mm (1 inch). Wall thickness: 1.65 mm. ID: 22.1 mm. Working pressure: 16 bar at 20 degrees Celsius. Temperature range: minus 50 to 200 degrees Celsius. Surface: electropolished interior, passivated exterior. Length: 6 meters per piece. Certification: CE, PED, ASTM A312. Mill certificate: EN 10204 3.1. KITOZER, 5 year warranty. End caps: plastic protectors included.

Applications

Primary applications include data center primary cooling loops, CDU inlet and outlet hardlines, row manifold piping, immersion cooling tank connections, and semiconductor fab secondary loops. The tubing is also used in pharmaceutical process cooling, food and beverage pasteurization loops, power converter cooling skids, and district cooling branch piping. In HPC facilities, DN20 stainless tubing forms the backbone of the secondary loop between CDU and row manifolds. The tubing is suitable for deionized water, ethylene and propylene glycol solutions, dielectric fluids, and corrosion-inhibited water-glycol mixtures.

Advantages and Features

316L stainless steel provides superior corrosion resistance, especially in deionized water and chloride-containing environments. The low-carbon composition resists intergranular corrosion after orbital welding. The electropolished interior reduces fouling and biofilm. Tight tolerances ensure compatibility with compression and press fittings. The tubing has a 50-plus year service life. It is fire-resistant and does not degrade with UV exposure. The material is fully recyclable. The smooth interior provides high flow capacity with low pressure drop. KITOZER supplies mill certificates for traceability.

Installation and Maintenance

Use orbital TIG welding for permanent primary loop joints, or press/compression fittings for demountable connections. Clean tube ends before fitting. Support tubing with pipe hangers every 1.5 meters. Allow for thermal expansion with loop offsets or expansion joints. After installation, pressure test at 1.5 times working pressure. Flush the loop thoroughly before first fill. Inspect welded joints annually for signs of corrosion or weeping. Passivate after welding with citric acid or nitric acid passivation. Insulate exterior surfaces to prevent condensation. Keep a record of all joint locations and installation dates.

System Integration Notes

When selecting KITOZER piping for a cooling loop, consider the coolant chemistry, pressure rating, and installation method. Stainless steel tubing is suitable for deionized water and high-purity loops, while copper and CuNi tubing are used in water-glycol and seawater applications. Plan for thermal expansion with loop offsets or expansion joints. Support tubing at intervals specified by the industry standard, and allow for movement at bends. After installation, pressure test the loop at 1.5 times working pressure before commissioning. Flush thoroughly to remove welding slag, Teflon tape fragments, and manufacturing residue. KITOZER recommends documenting each joint location and installation date for future reference. Inspect welded and brazed joints annually for signs of corrosion or weeping. Use compatible fittings to avoid galvanic corrosion between dissimilar metals.

Best Practices

Long-term piping reliability depends on disciplined installation practices. Before installation, inspect each tube length for internal contamination, and cap open ends at all times. During fabrication, deburr tube ends thoroughly to avoid flow disturbances. After welding, passivate the joint with citric acid or nitric acid treatment to restore the passive oxide layer. During pressure testing, use water, not air, and follow a staged pressure ramp. After the test, flush the loop to remove test debris. KITOZER recommends installing permanent pressure test ports at strategic points, so that future tests can be done without temporary fittings. Inspect piping annually, focusing on joints, hangers, and areas near pumps and valves where vibration is highest. Replace any hanger that shows deformation. Insulate piping in humid spaces to prevent condensation. Keep a record of all joint locations and repair history.

Price

From $28/meter. Contact +86 13922289957 for DN20 316L tubing pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top